116 research outputs found
Variaciones del metabolismo del nitrógeno en nódulos radicales de habas (Vicia faba L.) a lo largo del fotoperiodo.
Diurnal variations in acetylene reduction is shown in nitro gen-fixing faba bean.
The highest values for ARA occurred during the light period, while the lowest values
were recorded during the dark periodo However, the glutamate synthase cycle enzymes
(GS and NADH-GOGAT) and NADH-GDH show rhythmic behaviour on a cycle of 16
h, with maximum and minimum activities both being observed during the photoperiod
as well the dark periodoLa reducción de acetileno en plantas de haba fijadoras de nitrógeno, mostró
diferencias entre el día y la noche. Los mayores valores de ARA se detectaron durante
el periodo de luz, mientras que en periodo de oscuridad los valores fueron inferiores.
Por otra parte, las enzimas del ciclo de la glutamato sintasa (GS y NADH-GOGAT) y
la NADH-GDH mostraron un comportamiento cíclico de 16 horas, observándose actividades
máximas y mínimas tanto en el periodo de luz como en el de oscuridad
Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services
Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated.
Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis.
Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score.
Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images
Efficacy of laser shock processing of biodegradable Mg and Mg-1Zn alloy on their in vitro corrosion and bacterial response
Laser shock processing (LSP) is increasingly applied as an effective technology for improving the properties of different metallic components. This is done principally to enhance their corrosion and fatigue life behaviour, stress corrosion cracking resistance, etc. In this paper, LSP has been applied to a commercially pure Mg and a Mg-1Zn alloy (wt%) which is aimed to be used as a biodegradable material for biomedical applications. The rational for microalloying with Zn is not only influencing the bacterial response, but also enhancing corrosion resistance and mechanical strength of Mg without causing any toxic effect. The present work is focussed on the examination of the effects of the LSP treatment on the relevant surface related properties of the samples and their correlation with the surface and subsurface induced modifications such as residual stress state, microstructural, roughness, hardness, etc. Central to this investigation is the study of the corrosion response and antibacterial properties against Staphylococcus epidermidis of the different samples as a function of material and LSP parameters. The results show that the application of LSP introduces compressive residual stresses up to 1 mm deep. This occurs together with a significant improvement in corrosion resistance, and less bacterial colonization.Peer reviewe
Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies: a multicenter study in 21 Spanish pulmonology services
Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other
cross infections, but the bronchoscopist’s perception of its quality has not been evaluated.
Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional
study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at
the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of cen‑
tral tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM
analysis.
Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the
median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for
ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the
bronchoscopist was satisfed in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the
aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores>70/100 from the frst procedure and from the 9th procedure more than 80% of the scores
exceeded the 80/100 score
Bronchoscopist's perception of the quality of the single-use bronchoscope (Ambu aScope4™) in selected bronchoscopies : a multicenter study in 21 Spanish pulmonology services
Background: The disposable bronchoscope is an excellent alternative to face the problem of SARS-CoV-2 and other cross infections, but the bronchoscopist's perception of its quality has not been evaluated. Methods: To evaluate the quality of the Ambu-aScope4 disposable bronchoscope, we carried out a cross-sectional study in 21 Spanish pulmonology services. We use a standardized questionnaire completed by the bronchoscopists at the end of each bronchoscopy. The variables were described with absolute and relative frequencies, measures of central tendency and dispersion depending on their nature. The existence of learning curves was evaluated by CUSUM analysis. Results: The most frequent indications in 300 included bronchoscopies was bronchial aspiration in 69.3% and the median duration of these was 9.1 min. The route of entry was nasal in 47.2% and oral in 34.1%. The average score for ease of use, image, and aspiration quality was 80/100. All the planned techniques were performed in 94.9% and the bronchoscopist was satisfied in 96.6% of the bronchoscopies. They highlighted the portability and immediacy of the aScope4TM to start the procedure in 99.3%, the possibility of taking and storing images in 99.3%. The CUSUM analysis showed average scores > 70/100 from the first procedure and from the 9th procedure more than 80% of the scores exceeded the 80/100 score. Conclusions: The aScope4™ scored well for ease of use, imaging, and aspiration. We found a learning curve with excellent scores from the 9th procedure. Bronchoscopists highlighted its portability, immediacy of use and the possibility of taking and storing images
A922 Sequential measurement of 1 hour creatinine clearance (1-CRCL) in critically ill patients at risk of acute kidney injury (AKI)
Meeting abstrac
- …