    Two-year longitudinal evaluation of a second-generation thin-strut sirolimus-eluting bioresorbable coronary scaffold with hybrid cell design in porcine coronary arteries

    Get PDF
    Background: The first commercially available bioresorbable scaffold (BRS) had a strut thickness of 156 microns. As such, it had the potential for delivery challenges and higher thrombogenicity. The aim herein, is to evaluate biomechanical performance, pharmacokinetics and vascular healing of a novel thin strut (100 μm) sirolimus eluting BRS (MeRes-100, Meril Life Sciences, Gujarat, India) against the once clinically used BRS (Absorb BVS, Abbott, Santa Clara, CA) in porcine coronary arteries. Methods: Following device implantation, angiographic and optical coherence tomography (OCT) evaluation were performed at 45, 90, 180 days, 1 year and 2 years. Histological evaluation was per­formed at 30, 90 and 180 days. Results: At 2 years, both lumen (MeRes-100 7.07 ± 1.82 mm2 vs. Absorb BVS 7.57 ± 1.39 mm2, p = NS) and scaffold areas (MeRes-100 9.73 ± 1.80 mm2 vs. Absorb BVS 9.67 ± 1.25 mm2, p = NS) were comparable between tested and control scaffolds. Also, the late lumen area gain at 2 years was similar in both groups tested (MeRes-100 1.03 ± 1.98 mm2 vs. Absorb BVS 0.85 ± 1.56 mm2, p = NS). Histologic examination up to 6 months showed comparable healing and inflammation profiles for both devices. Conclusions: The novel sirolimus-eluting BRS with thinner struts and hybrid cell design showed similar biomechanical durability and equivalent inhibition of neointimal proliferation when compared to the first-ever Absorb BVS up to 2 years in normal porcine coronary arteries

    Optimizing flushing parameters in intracoronary optical coherence tomography: an in vivo swine study

    Get PDF
    Intracoronary optical frequency domain imaging (OFDI), requires the displacement of blood for clear visualization of the artery wall. Radiographic contrast agents are highly effective at displacing blood however, may increase the risk of contrast-induced nephropathy. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. The aim of this work was to determine the optimal flushing parameters necessary to reliably perform intracoronary OFDI while reducing the volume of administered radiographic contrast, and assess the influence of flushing media choice on vessel wall measurements. 144 OFDI pullbacks were acquired together with synchronized EKG and intracoronary pressure wire recordings in three swine. OFDI images were graded on diagnostic quality and quantitative comparisons of flushing efficiency and intracoronary cross-sectional area with and without precise refractive index calibration were performed. Flushing media with higher viscosities resulted in rapid and efficient blood displacement. Media with lower viscosities resulted in increased blood-media transition zones, reducing the pullback length of diagnostic quality images obtained. Flushing efficiency was found to increase with increases in flow rate and duration. Calculations of lumen area using different flushing media were significantly different, varying up to 23 % (p < 0.0001). This error was eliminated with careful refractive index calibration. Flushing media viscosity, flow rate, and flush duration influence the efficiency of blood displacement necessary for obtaining diagnostic quality OFDI images. For patients with sensitivity to contrast, to reduce the risk of contrast induced nephrotoxicity we recommend that intracoronary OFDI be conducted with flushing solutions containing little or no radiographic contrast. In addition, our findings show that careful refractive index compensation should be performed, taking into account the specific contrast agent used, in order to obtain accurate intravascular OFDI measurements.Merck & Co., Inc.National Institutes of Health (U.S.) (Grant Numbers R00CA134920, R01HL076398, R01HL093717

    Stent healing response following delivery of paclitaxel via durable polymeric matrix versus iopromide-based balloon coating in the familial hypercholesterolaemic swine model of coronary injury.

    No full text
    AIMS: The routine use of paclitaxel-coated balloons (PCB) in combination with bare metal stents (BMS) in de novo coronary lesions has been questioned. In this study, we aimed to compare the vascular response of BMS implanted using a second-generation PCB (BMS+PCB) with the TAXUS stent (PES) and a BMS control (BMS) in the familial hypercholesterolaemic swine (FHS) model of coronary injury. METHODS AND RESULTS: A total of 17 stents (PES=6, BMS+PCB=6, and BMS=5) were implanted in the coronary territory of 10 FHS using a 20% overstretch injury ratio. Imaging evaluation (QCA and IVUS) was conducted in all animals at baseline and 28 days following stent implantation. Following terminal imaging all animals were euthanised and stented coronary segments harvested for histological evaluation. At 28 days, the lowest degree of percentage diameter stenosis by QCA was achieved by the PES (2.9 ± 9%) followed by the BMS+PCB (9.5 ± 16.4%) and the BMS group (25.65 ± 18.7%, p CONCLUSIONS: In the FHS coronary injury model, BMS implantation using a PCB yields a degree of neointimal inhibition comparable to the PES. The BMS+PCB combination presented lower degrees of inflammation and fibrin deposition; however, signs of delayed healing were still present

    Tissue uptake, distribution, and healing response after delivery of paclitaxel via second-generation iopromide-based balloon coating: a comparison with the first-generation technology in the iliofemoral porcine model.

    Get PDF
    OBJECTIVES: This study sought to evaluate vascular drug uptake, distribution and response of second-generation paclitaxel coated balloon (PCB) (Cotavance, MEDRAD Interventional, Indianola, Pennsylvania) and compare it with first-generation technology, containing identical excipient and drug concentration. BACKGROUND: Original PCB technologies displayed a heterogeneous deposition of crystalline paclitaxel-iopromide inside the balloon folds, whereas second-generation PCBs consisted of more homogeneous, circumferential coatings. METHODS: Paclitaxel tissue uptake was assessed in 20 iliofemoral arteries of a domestic swine. Vascular healing response was assessed in the familial hypercholesterolemic model of iliofemoral in-stent restenosis. Three weeks after bare-metal stent implantation, vascular segments were randomly revascularized with first-generation PCBs (n = 6), second-generation PCBs (n = 6), or plain balloon angioplasty (PBA) (n = 6). At 28 days, angiographic and histological evaluation was performed in all treated segments. RESULTS: One-hour paclitaxel tissue uptake was 42% higher in the second-generation PCBs (p = 0.03) and resulted in more homogeneous segment-to-segment distribution compared with first-generation PCBs. Both angiography (percentage of diameter stenosis: second-generation 11.5 ± 11% vs. first-generation 21.9 ± 11% vs. PBA 46.5 ± 10%; p \u3c 0.01) and histology (percentage of area stenosis: second-generation 50.5 ± 7% vs. first-generation 54.8 ± 18% vs. PBA 78.2 ± 9%; p \u3c 0.01) showed a decrease in neointimal proliferation in both PCB groups. Histological variance of the percentage of area stenosis was lower in second-generation compared with first-generation PCBs (51.7 vs. 328.3; p = 0.05). The presence of peristrut fibrin deposits (0.5 vs. 2.4; p \u3c 0.01) and medial smooth muscle cell loss (0 vs. 1.7; p \u3c 0.01) were lower in the second-generation compared with first-generation PCBs. CONCLUSIONS: In the experimental setting, second-generation PCB showed a comparable efficacy profile and more favorable vascular healing response when compared to first-generation PCB. The clinical implications of these findings require further investigation