15 research outputs found
The James Webb Space Telescope Mission
Twenty-six years ago a small committee report, building on earlier studies,
expounded a compelling and poetic vision for the future of astronomy, calling
for an infrared-optimized space telescope with an aperture of at least .
With the support of their governments in the US, Europe, and Canada, 20,000
people realized that vision as the James Webb Space Telescope. A
generation of astronomers will celebrate their accomplishments for the life of
the mission, potentially as long as 20 years, and beyond. This report and the
scientific discoveries that follow are extended thank-you notes to the 20,000
team members. The telescope is working perfectly, with much better image
quality than expected. In this and accompanying papers, we give a brief
history, describe the observatory, outline its objectives and current observing
program, and discuss the inventions and people who made it possible. We cite
detailed reports on the design and the measured performance on orbit.Comment: Accepted by PASP for the special issue on The James Webb Space
Telescope Overview, 29 pages, 4 figure
Determining crystal structures through crowdsourcing and coursework
We show here that computer game players can build high-quality crystal structures. Introduction of a new feature into the computer game Foldit allows players to build and real-space refine structures into electron density maps. To assess the usefulness of this feature, we held a crystallographic model-building competition between trained crystallographers, undergraduate students, Foldit players and automatic model-building algorithms. After removal of disordered residues, a team of Foldit players achieved the most accurate structure. Analysing the target protein of the competition, YPL067C, uncovered a new family of histidine triad proteins apparently involved in the prevention of amyloid toxicity. From this study, we conclude that crystallographers can utilize crowdsourcing to interpret electron density information and to produce structure solutions of the highest quality
Variation in Endoscopic Activity Assessment and Endoscopy Score Validation in Adults With Eosinophilic Esophagitis.
Eosinophilic esophagitis (EoE) is assessed endoscopically (endoscopic activity), based on grades of edema, rings, exudates, furrows, and strictures (EREFS). We examined variations in endoscopic assessments of severity, developed and validated 3 EREFS-based scoring systems, and assessed responsiveness of these systems using data from a randomized placebo-controlled trial of patients with EoE.
For the development set, 5 gastroenterologists reviewed EREFS findings from 266 adults with EoE and provided endoscopist global assessment scores (EndoGA, scale of 0 to 10); variation (ΔEndoGA) was assessed using linear regression. We evaluated simple scores (features given arbitrary values from 0 to 3) and developed 2 scoring systems (adjusted score range, 0-100). We then fitted our linear regression model with mean EndoGA to data from 146 adults recruited in centers in Switzerland and the United States between April 2011 and December 2012. For the validation set, we collected data from 120 separate adults (recruited in centers in Switzerland and the United States between May 2013 and July 2014), assessing regression coefficient-based scores using Bland-Altman method. We assessed the responsiveness of our scoring systems using data from a randomized trial of patients with EoE given fluticasone (n=16) or placebo (n=8).
The distribution of EndoGA values differed among endoscopists (mean ΔEndoGA, 2.6±1.8; range 0-6.6). We developed 2 regression-based scoring systems to assess overall and proximal and distal esophageal findings; variation in endoscopic features accounted for more than 90% of the mean EndoGA variation. In the validation group, differences between mean EndoGA and regression-based scores were small (ranging from -4.70 to 2.03), indicating good agreement. In analyses of data from the randomized trial, the baseline to end of study change in patients given fluticasone was a reduction of 24.3 in simple score (reduction of 4.6 in patients given placebo, P=.052); a reduction of 23.5 in regression-based overall score (reduction of 6.56 in patients given placebo, P=.12), and a reduction of 23.8 (reduction of 8.44 in patients given placebo, P=.11).
Assessments of endoscopic activity in patients with EoE vary among endoscopists. In an analysis of data from a randomized controlled trial, we found that newly developed scoring systems are no better than simple scoring system in detecting changes in endoscopic activity. These results support the use of a simple scoring system in evaluation of endoscopic activity in patients with EoE. clinicaltrials.gov no: NCT00939263 and NCT01386112
Recommended from our members
Variation in Endoscopic Activity Assessment and Endoscopy Score Validation in Adults With Eosinophilic Esophagitis.
Background & aimsEosinophilic esophagitis (EoE) is assessed endoscopically (endoscopic activity), based on grades of edema, rings, exudates, furrows, and strictures (EREFS). We examined variations in endoscopic assessments of severity, developed and validated 3 EREFS-based scoring systems, and assessed responsiveness of these systems using data from a randomized placebo-controlled trial of patients with EoE.MethodsFor the development set, 5 gastroenterologists reviewed EREFS findings from 266 adults with EoE and provided endoscopist global assessment scores (EndoGA, scale of 0 to 10); variation (ΔEndoGA) was assessed using linear regression. We evaluated simple scores (features given arbitrary values from 0 to 3) and developed 2 scoring systems (adjusted score range, 0-100). We then fitted our linear regression model with mean EndoGA to data from 146 adults recruited in centers in Switzerland and the United States between April 2011 and December 2012. For the validation set, we collected data from 120 separate adults (recruited in centers in Switzerland and the United States between May 2013 and July 2014), assessing regression coefficient-based scores using Bland-Altman method. We assessed the responsiveness of our scoring systems using data from a randomized trial of patients with EoE given fluticasone (n=16) or placebo (n=8).ResultsThe distribution of EndoGA values differed among endoscopists (mean ΔEndoGA, 2.6±1.8; range 0-6.6). We developed 2 regression-based scoring systems to assess overall and proximal and distal esophageal findings; variation in endoscopic features accounted for more than 90% of the mean EndoGA variation. In the validation group, differences between mean EndoGA and regression-based scores were small (ranging from -4.70 to 2.03), indicating good agreement. In analyses of data from the randomized trial, the baseline to end of study change in patients given fluticasone was a reduction of 24.3 in simple score (reduction of 4.6 in patients given placebo, P=.052); a reduction of 23.5 in regression-based overall score (reduction of 6.56 in patients given placebo, P=.12), and a reduction of 23.8 (reduction of 8.44 in patients given placebo, P=.11).ConclusionAssessments of endoscopic activity in patients with EoE vary among endoscopists. In an analysis of data from a randomized controlled trial, we found that newly developed scoring systems are no better than simple scoring system in detecting changes in endoscopic activity. These results support the use of a simple scoring system in evaluation of endoscopic activity in patients with EoE. clinicaltrials.gov no: NCT00939263 and NCT01386112