72 research outputs found
Surface stiffening and enhanced photoluminescence of ion implanted cellulose - polyvinyl alcohol - silica composite
Novel Cellulose (Cel) reinforced polyvinyl alcohol (PVA)-Silica (Si) composite which has good stability and in vitro degradation was prepared by lyophilization technique and implanted using N3+ ions of energy 24 keV in the fluences of 1 x 10(15), 5 x 10(15) and 1 x 10(16) ions/cm(2). SEM analysis revealed the formation of microstructures, and improved the surface roughness on ion implantation. In addition to these structural changes, the implantation significantly modified the luminescent, thermal and mechanical properties of the samples. The elastic modulus of the implanted samples has increased by about 50 times compared to the pristine which confirms that the stiffness of the sample surface has increased remarkably on ion implantation. The photoluminescence of the native cellulose has improved greatly due to defect site, dangling bonds and hydrogen passivation. Electric conductivity of the ion implanted samples was improved by about 25%. Hence, low energy ion implantation tunes the mechanical property, surface roughness and further induces the formation of nano structures. MG63 cells seeded onto the scaffolds reveals that with the increase in implantation fluence, the cell attachment, viability and proliferation have improved greatly compared to pristine. The enhancement of cell growth of about 59% was observed in the implanted samples compared to pristine. These properties will enable the scaffolds to be ideal for bone tissue engineering and imaging applications.G.M.S. acknowledges CSIR, India (Grant no: 09/468 (0474)/2013-EMR-I) and S.N.K. thanks the award of Erasmus-Mundus Svaagata for providing financial support to carry out this research. G.M.S., N.S. and S.N.K. acknowledge the support of UGC National facility for characterization facility. J.A.G.T. acknowledges the support of the Spanish Ministry of Economy and Competitiveness (MINECO) through the project DPI2015-65401-C3-2-R (including the FEDER financial support). CIBER-BBN, Spain is an initiative funded by the VI National R&D Plan 2008-2011, Iniciativa Ingenio 2010, Consolider Program. CIBER actions are financed by the Instituto de Salud Carlos III with assistance from the European Regional Development Fund. AFM was conducted by the microscopy service of the UPV, whose advice was greatly appreciated.Shanthini, GM.; Sakthivel, N.; Menon, R.; Nabhiraj, PY.; Gómez-Tejedor, JA.; Meseguer Dueñas, JM.; Gómez Ribelles, JL.... (2016). Surface stiffening and enhanced photoluminescence of ion implanted cellulose - polyvinyl alcohol - silica composite. Carbohydrate Polymers. 153:619-630. https://doi.org/10.1016/j.carbpol.2016.08.016S61963015
On complex-valued 2D eikonals. Part four: continuation past a caustic
Theories of monochromatic high-frequency electromagnetic fields have been
designed by Felsen, Kravtsov, Ludwig and others with a view to portraying
features that are ignored by geometrical optics. These theories have recourse
to eikonals that encode information on both phase and amplitude -- in other
words, are complex-valued. The following mathematical principle is ultimately
behind the scenes: any geometric optical eikonal, which conventional rays
engender in some light region, can be consistently continued in the shadow
region beyond the relevant caustic, provided an alternative eikonal, endowed
with a non-zero imaginary part, comes on stage. In the present paper we explore
such a principle in dimension We investigate a partial differential system
that governs the real and the imaginary parts of complex-valued two-dimensional
eikonals, and an initial value problem germane to it. In physical terms, the
problem in hand amounts to detecting waves that rise beside, but on the dark
side of, a given caustic. In mathematical terms, such a problem shows two main
peculiarities: on the one hand, degeneracy near the initial curve; on the other
hand, ill-posedness in the sense of Hadamard. We benefit from using a number of
technical devices: hodograph transforms, artificial viscosity, and a suitable
discretization. Approximate differentiation and a parody of the
quasi-reversibility method are also involved. We offer an algorithm that
restrains instability and produces effective approximate solutions.Comment: 48 pages, 15 figure
Long-term survivors following autologous haematopoetic stem cell transplantation have significant defects in their humoral immunity against vaccine preventable diseases, years on from transplant
Current international guidelines recommend routinely vaccinating haematopoetic stem cell transplant (HSCT) recipients. Despite significant infection-related mortality following autologous HSCT, routine vaccination programmes (RVP) completion is poor. For recovered HSCT recipients, it is uncertain whether catch-up vaccination remains worthwhile years later.
To determine potential susceptibility to vaccine preventable infections, we measured antibody titres in 56 patients, a median of 7 years (range 0–29) following autologous HSCT, who had not completed RVP. We found that almost all participants had inadequate titres against diphtheria (98.2%) and pneumococcal infection (100%), and a significant proportion had inadequate titres against measles (34.5%). Of those subsequently vaccinated according to available guidelines, many mounted adequate serological responses.
These data suggest a pragmatic catch-up approach for autologous HSCT recipients who have not completed RVP is advisable, with universal vaccination against some pathogens (e.g. Streptococcus pneumoniae and diphtheria) and serologically-guided approaches for others (e.g. measles and varicella zoster virus)
- …