18 research outputs found

    Neutrino Interactions In Oscillation Experiments

    Get PDF
    We calculate neutrino induced cross-sections relevant for oscillation experiments, including the τ\tau-lepton threshold for quasi-elastic, resonance and deep inelastic scattering. In addition to threshold effects, we include nuclear corrections for heavy targets which are moderate for quasi-elastic and large for single pion production. Nuclear effects for deep inelastic reactions are small. We present cross sections together with their nuclear corrections for various channels which are useful for interpreting the experimental results and for determining parameters of the neutrino sector..Comment: 24 pages, 18 figure

    A comparison of real-time compression ultrasonography with impedance plethysmography for the diagnosis of deep-vein thrombosis in symptomatic outpatients

    No full text
    Impedance plethysmography performed serially over a one-week period has been shown to be an effective diagnostic strategy for patients with clinically suspected acute deep-vein thrombosis. Compression ultrasonography has a high sensitivity and specificity for the detection of proximal-vein thrombosis. The clinical value of repeated ultrasonography in the management of symptomatic deep-vein thrombosis is unknown. We conducted a randomized trial in 985 consecutive outpatients with clinically suspected deep-vein thrombosis to compare the diagnostic value of serial impedance plethysmography (494 patients) and serial compression ultrasonography (491 patients). We compared the positive predictive values of both tests for the diagnosis of venous thrombosis, using contrast venography as a reference. The frequencies of venous thromboembolism during a six-month follow-up period were also compared in patients with repeatedly normal results in order to evaluate the safety of withholding anticoagulant therapy from such patients. The positive predictive value of an abnormal ultrasonogram was 94 percent (95 percent confidence interval, 87 to 98 percent), whereas the predictive value of impedance plethysmography was 83 percent (95 percent confidence interval, 75 to 90 percent) (P = 0.02). In patients with repeatedly normal results, the incidence of venous thromboembolism during the six-month follow-up period was 1.5 percent (95 percent confidence interval, 0.5 to 3.3 percent) for serial compression ultrasonography, as compared with 2.5 percent (95 percent confidence interval, 1.2 to 4.6 percent) for serial impedance plethysmography. In making the diagnosis of deep-vein thrombosis in symptomatic outpatients, serial compression ultrasonography is preferable to impedance plethysmography, in view of its superior performance in detecting venous thrombosi

    The use of the D-dimer test in combination with non-invasive testing versus serial non-invasive testing alone for the diagnosis of deep-vein thrombosis

    No full text
    We studied the usefulness of the determination of plasma D-dimer levels (using an ELISA) in combination with non-invasive testing with impedance plethysmography (IPG) or real-time ultrasonography (US) for the diagnosis of deep-vein thrombosis (DVT), in outpatients with clinically suspected DVT. This combined approach was compared to serial non-invasive testing alone in these patients. The sensitivity of a positive D-dimer test (greater than 300 micrograms/l) for the presence of DVT was 100% (70/70 patients; 95% C.I.: 95-100%), whereas the specificity was 29% (69/239 patients; 95% C.I.: 23-34%). The proportion of patients in which a definitive decision about the presence or absence of DVT could be made on the day of referral, was calculated for both approaches. When applying the combined approach, in 42% of all referred patients the diagnosis of DVT could either be established or refuted on entry, as opposed to only 19% of patients using serial non-invasive testing alone. Also, the costs per DVT diagnosed were calculated for the two diagnostic approaches. For the diagnosis of DVT the costs using serial IPG were comparable to the costs using the combination of IPG and the D-dimer test. The same conclusion holds for the comparison of serial US with the combination of US and D-dimer testing. We conclude that for the diagnosis of DVT in symptomatic outpatients the combination of non-invasive testing with the D-dimer test might be preferred over serial non-invasive testing alone, although the safety of such an approach remains to be established in future management studie

    Risk of venous thrombosis with use of current low-dose oral contraceptives is not explained by diagnostic suspicion and referral bias

    No full text
    The magnitude of the relative risk of venous thrombosis caused by low-dose oral contraceptive use is still debated because previous studies might have been affected by diagnostic suspicion and referral bias. We conducted a case-control study in which the effect of diagnostic suspicion and referral bias was excluded. The study was performed in 2 diagnostic centers to which patients with clinically suspected deep vein thrombosis of the leg were referred. History of oral contraceptive use was obtained before objective testing for thrombosis. Young females with an objective diagnosis of deep vein thrombosis were considered case patients, and those who were referred with the same clinical suspicion but who had no thrombosis served as control subjects. Participants were seen between September 1, 1982, and October 18, 1995: 185 consecutive patients and 591 controls aged 15 to 49 years with a first episode of venous thrombosis and without malignant neoplasms, pregnancy, or known inherited clotting defects. The overall odds ratio for oral contraceptive use was 3.2 (95% confidence interval [CI], 2.3-4.5); after adjustment for age, family history of venous thrombosis, calendar time, and center, the odds ratio was 3.9 (95% CI, 2.6-5.7). In the idiopathic group (120 patients and 413 controls, excluding recent surgery, trauma, or immobilization), the odds ratio for oral contraceptive use was 3.8 (95% CI, 2.5-5.9); after adjustment, the odds ratio was 5.0 (95% CI, 3.1-8.2). In this study, in which patients and controls were subj ect to the same referral and diagnostic procedures, we found similar relative risk estimates for oral contraceptive use as in previous studies. We conclude that diagnostic suspicion and referral bias did not play an important role in previous studies and that the risk of venous thrombosis with use of current brands of oral contraceptives still exist

    Oral anticoagulation self-management and management by a specialist anticoagulation clinic: a randomised cross-over comparison

    No full text
    BACKGROUND: Vitamin K antagonist treatment is effective for prevention and treatment of thromboembolic events but frequent laboratory control and dose-adjustment are essential. Small portable devices have enabled patient self-monitoring of anticoagulation and self-adjustment of the dose. We compared this self-management of oral anticoagulant therapy with conventional management by a specialist anticoagulation clinic in a randomised cross-over study. METHODS: 50 patients on long-term oral anticoagulant treatment were included in a randomised controlled crossover study. Patients were self-managed or were managed by the anticoagulation clinic for a period of 3 months. After this period the alternative strategy was followed for each patient. Prothrombin time (expressed as international normalised ratio [INR]) were measured at intervals of 1-2 weeks in both periods without knowledge of type of management. The primary endpoint was the number of measurements within the therapeutic range (therapeutic target value +/-50.5 INR units). FINDINGS: There was no significant difference in the overall quality of control of anticoagulation between the two study periods. Patients were for 55% and for 49% of the treatment period within a range of +/-0.5 from the therapeutic target INR during self-management and anticoagulation clinic management, respectively (p=0.06). The proportion of patients who spent most time in the therapeutic target range was larger during self-management than during anticoagulation clinic-guided management. The odds ratio for a better control of anticoagulation (defined as the period of time in the therapeutic target range) during self-management compared with anticoagulation clinic-guided management was 4.6 (95% CI 2.1-10.2). A patient-satisfaction assessment showed superiority of self-management over conventional care. INTERPRETATION: Self-management of INR in the population in this study is feasible and appears to result in control of anticoagulation that is at least equivalent to management by a specialist anticoagulation clinic. It is also better appreciated by patients. Larger studies are required to assess the effect of this novel management strategy on the incidence of thromboembolic or bleeding complication
    corecore