6,754 research outputs found

    A Study of Initialization in Linux and OpenBSD

    Get PDF
    The code that initializes a system can be notoriously difficult to understand. In secure systems, initialization is critical for establishing a starting state that is secure. This paper explores two architectures used for bringing an operating system to its initial state, once the operating system gains control from the boot loader. Specifically, the ways in which the OpenBSD and Linux operating systems handle initialization are dissected

    MULTIPLE HARMONIC PLASMA EMISSION

    Get PDF
    Electromagnetic radiation at the plasma frequency and/or its second harmonic, the so-called plasma emission, is widely accepted as the fundamental process responsible for solar type II and III radio bursts. There have also been occasional observations of higher-harmonic plasma emissions in the solar-terrestrial environment. This paper presents the first demonstration of multiple harmonic emission by means of two-dimensional electromagnetic particle-in-cell simulation. This finding indicates that under certain circumstances the traditional mechanism of fundamental-harmonic pair emission might also be accompanied by higher-harmonic components. Consequently, the present findings are highly relevant to in situ observations of third- and/or higher-harmonic plasma emission in astrophysical and solar-terrestrial environments.open111313sciescopu

    A comparison of surgical outcomes between endoscopic and robotically assisted thyroidectomy: the authors’ initial experience

    Get PDF
    Background: The gasless, transaxillary endoscopic thyroidectomy (GTET) offers a distinct advantage over the conventional open operation by leaving no visible neck scar, and in an attempt to improve its ergonomics and surgical outcomes, the robotically assisted thyroidectomy (RAT) was introduced. The RAT uses the same endoscopic route as the GTET but with the assistance of the da Vinci S robotic system. Excellent results for RAT have been reported, but it remains unclear whether RAT offers any potential benefits over GTET. Methods: From June to December 2009, 46 patients underwent endoscopic thyroidectomy. Of these patients, 39 had surgery without the robot (GTET) and 7 had surgery with the robot (RAT). Demographics, surgical indications, operative findings, and postoperative outcomes were compared between the two groups. All the patients were followed up for at least 6 months after surgery. Results: Patient demographics, surgical indications, and extent of resection were similar between the two groups. The median total procedure time was significantly longer for RAT (149 min) than for GTET (100 min; p = 0.018), but the contralateral recurrent laryngeal nerve was more likely to identified in RAT (100%) than in GTET (42.9%; p = 0.070). On the average, GTET needed one more surgical assistant than RAT (1 vs. 0; ppublished_or_final_versionSpringer Open Choice, 21 Feb 201

    Conjugated polyelectrolyte nano field emission adlayers.

    Get PDF
    Here we report on a straightforward and rapid means of enhancing the field electron emission performance of nascent vertically aligned multi-walled carbon nanotubes by introducing a polar zwitterionic conjugated polyelectrolyte adlayer at the vacuum-emitter interface. We attribute the observed 66% decrease in turn-on electric field to the augmented emitter micro-morphology and shifted surface band structure. The composite emitters can be optically modulated by exploiting the absorption cross-section of the solution cast adlayer, which increases the local carrier concentration which broadens the effective electrostatic shape of the emitter during optical excitation. Assessment via scanning anode field emission microscopy reveals a 25% improvement in DC time stability, a significant reduction in long-term hysteresis shift, and a threefold increase in bandwidth during pulsed mode operation.Oppenheimer TrustThis is the final version of the article. It first appeared from the Royal Society of Chemistry via http://dx.doi.org/10.1039/c6nh00071

    Movement variability in stroke patients and controls performing two upper limb functional tasks: a new assessment methodology

    Get PDF
    Background: In the evaluation of upper limb impairment post stroke there remains a gap between detailed kinematic analyses with expensive motion capturing systems and common clinical assessment tests. In particular, although many clinical tests evaluate the performance of functional tasks, metrics to characterise upper limb kinematics are generally not applicable to such tasks and very limited in scope. This paper reports on a novel, user-friendly methodology that allows for the assessment of both signal magnitude and timing variability in upper limb movement trajectories during functional task performance. In order to demonstrate the technique, we report on a study in which the variability in timing and signal magnitude of data collected during the performance of two functional tasks is compared between a group of subjects with stroke and a group of individually matched control subjects. Methods: We employ dynamic time warping for curve registration to quantify two aspects of movement variability: 1) variability of the timing of the accelerometer signals' characteristics and 2) variability of the signals' magnitude. Six stroke patients and six matched controls performed several trials of a unilateral ('drinking') and a bilateral ('moving a plate') functional task on two different days, approximately 1 month apart. Group differences for the two variability metrics were investigated on both days. Results: For 'drinking from a glass' significant group differences were obtained on both days for the timing variability of the acceleration signals' characteristics (p = 0.002 and p = 0.008 for test and retest, respectively); all stroke patients showed increased signal timing variability as compared to their corresponding control subject. 'Moving a plate' provided less distinct group differences. Conclusion: This initial application establishes that movement variability metrics, as determined by our methodology, appear different in stroke patients as compared to matched controls during unilateral task performance ('drinking'). Use of a user-friendly, inexpensive accelerometer makes this methodology feasible for routine clinical evaluations. We are encouraged to perform larger studies to further investigate the metrics' usefulness when quantifying levels of impairment

    Occupational noise exposure is associated with hypertension in China: Results from project ELEFANT

    Get PDF
    OBJECTIVES: We investigated the association between occupational noise exposure and the risk of elevated blood pressure and hypertension by stage in young adults. METHODS: We utilized 124,286 young adults (18-40 years) from the Project ELEFANT study. We categorized occupational noise exposure as high (75 dBA noise exposure for more than 4 hours per day) or low, and measured blood pressure (mmHg) and categorized participants by hypertension stage (normal, elevated, Stage 1, Stage 2). We applied adjusted logistic regression models to identify associations with hypertension risk, and we further examined the noise-BMI, noise-gender, and noise-residence interactions on hypertension risk in separate models. RESULTS: High occupational noise exposure was associated with increases in blood pressure among participants with elevated blood pressure (Estimate = 0.23, 95% CI: 1.09, 1.46, p = 0.0009), in Stage 1 hypertension (Estimate = 0.15, 95% CI: 1.06, 1.25, p = 0.0008), and in Stage 2 hypertension (Estimate = 0.41 95% CI: 1.31, 1.73, p<0.0001). Likewise, noise exposure-BMI interaction was consistently positively associated with increases in blood pressure in participants with elevated blood pressure (Estimate = 0.71, 95% CI: 1.55, 2.69, p<0.0001), in Stage 1 hypertension (Estimate = 0.78, 95% CI: 1.82, 2.61, p<0.0001), and in Stage 2 hypertension (Estimate = 2.06, 95% CI: 5.64, 10.81, p<0.0001). The noise exposure-male interaction showed higher risk for hypertension compared to the noise exposure-female interaction in participants with elevated blood pressure (Estimate = 1.24, 95% CI: 2.56, 4.71, p<0.0001), Stage 1 (Estimate = 1.67, 95% CI: 4.34, 6.42, p<0.0001) and Stage 2 hypertension (Estimate = 1.70, 95% CI: 3.86, 7.77, p<0.0001). Finally, we found that noise exposure-urban interaction was consistently associated with an increase in blood pressure in elevated blood pressure (Estimate = 0.32, 95% CI: 1.19, 1.62, p<0.0001) and in Stage 2 hypertension (Estimate = 0.44, 95% CI: 1.31, 1.80, p<0.0001)

    Regulation of Transgene Expression in Tumor Cells by Exploiting Endogenous Intracellular Signals

    Get PDF
    Recently, we have proposed a novel strategy for a cell-specific gene therapy system based on responses to intracellular signals. In this system, an intracellular signal that is specifically and abnormally activated in the diseased cells is used for the activation of transgene expression. In this study, we used protein kinase C (PKC)α as a trigger to activate transgene expression. We prepared a PKCα-responsive polymer conjugate [PPC(S)] and a negative control conjugate [PPC(A)], in which the phosphorylation site serine (Ser) was replaced with alanine (Ala). The phosphorylation for polymer/DNA complexes was determined with a radiolabel assay using [γ-32P]ATP. PPC(S)/DNA complexes were phosphorylated by the addition of PKCα, but no phosphorylation of the PPC(A)/DNA complex was observed. Moreover, after microinjection of polymer/GFP-encoding DNA complexes into HepG2 cells at cation/anion (C/A) ratios of 0.5 to 2.0, significant expression of GFP was observed in all cases using PPC(S)/DNA complexes, but no GFP expression was observed in the negative control PPC(A)/DNA complex-microinjected cells at C/A ratios of 1.0 and 2.0. On the other hand, GFP expression from PPC(S)/DNA complexes was completely suppressed in cells pretreated with PKCα inhibitor (Ro31-7549). These results suggest that our gene regulation system can be used for tumor cell-specific expression of a transgene in response to PKCα activity

    Characterization of Fine Particulate Matter and Associations between Particulate Chemical Constituents and Mortality in Seoul, Korea

    Get PDF
    Background: Numerous studies have linked fine particles [≤ 2.5 µm in aerodynamic diameter (PM2.5)] and health. Most studies focused on the total mass of the particles, although the chemical composition of the particles varies substantially. Which chemical components of fine particles that are the most harmful is not well understood, and research on the chemical composition of PM2.5 and the components that are the most harmful is particularly limited in Asia
    corecore