122 research outputs found

    Current perspectives on dental adhesion: (3) Adhesion to intraradicular dentin: Concepts and applications

    Full text link
    Adhesion science is one of the greatest contributions to restorative dentistry. Adhesion not only established the current principles of tissue preservation, but also allowed for the production of more hermetic and long-lasting restorations. Although adhesive strategies are routinely used in most clinical situations, adhesion to root dentin is still a major challenge. The presence of humidity together with less intertubular dentin are factors that limit the adhesive potential of root dentin. This situation is more unfavorable in endodontically treated teeth prepared for prefabricated or custom-made intraradicular posts; these procedures may alter the mechanical properties of teeth by modifying the viable dentin surface for adhesion. Also, contaminants deposited on the dentin surface are difficult to remove through conventional techniques. Moreover, root canal morphology has a very unfavorable C-factor, bringing undesirable effects resulting from polymerization contraction of resin-based materials. However, the differences between coronal and root dentin are not a barrier for dentin adhesion. Standardization of procedures and care during clinical steps are fundamental to the success of adhesion to coronal or intraradicular dentin. Thus, it is essential to know the anatomy of the root structure, the factors that interfere with intraradicular adhesion, as well as the current adhesive materials and techniques

    Graphene for zirconia and titanium composites in dental implants: Significance and predictions

    Get PDF
    Purpose of Review: Graphene is introduced in dentistry as a material to be used in the fabrication or coating of dental implants due to its biocompatibility, ability to physically interact with biomolecules and very high surface area. This review highlights the current knowledge on the general properties of graphene, potential benefits especially when used in zirconia-based implants, as composite materials and coatings. Recent Findings: The literature reviewed showed a growing body of evidence supporting the use of graphene-based material, associated with titanium or zirconia as a coating or composite material that helps in cell viability, differentiation and proliferation, improving the bioactivity, osseointegration, physical, chemical and mechanical properties particularly zirconia. Graphene-based materials present great potential for biomedical applications especially when used in the form of nanostructured biological coatings that can be obtained through reproducible and economical processes. Summary: The use of graphene as a composite implant material or coating may have great potential for osseointegration and bone regeneration, providing that, features including hydrophilicity, protein adsorption capacity, oxygen content and effect of external parameters such as temperature, pH and ionic strength need further elucidations before they can be implemented as a coating or composite material for dental implants.Institute for Empirical Research in Economics, University of Zurich ; Neuroscience Center Zurich, University of Zuric

    Adhesion behavior of conventional and high‐translucent zirconia: Effect of surface conditioning methods and aging using an experimental methodology

    Full text link
    Objective: Evaluate the adhesive behavior of conventional and high-translucent zirconia after surface conditioning and hydrothermal aging. Materials and methods: Conventional (ZrC) and high-translucent zirconia (ZrT) specimens were divided into six groups: without surface treatment (ZrC and ZrT), air-borne particle abrasion with 50-ÎŒm Al2 O3 sized particles (ZrC-AO and ZrT-AO), and tribochemical treatment with 30-ÎŒm silica modified Al2 O3 sized particles (ZrC-T and ZrT-T). Zirconia specimens were treated using an MDP-containing universal adhesive and bonded to two resins blocks with an adhesive luting cement. Microbar specimens with cross-sectioned areas of 1 mm2 were achieved. Half of the microbars were subjected to hydrothermal aging. Bond strength was evaluated by microtensile bond strength test and statistically evaluated by the Weibull analysis. Results: Roughness of the ZrC-AO and ZrT-AO groups were statistically higher. Bond strength analysis revealed higher bond strength for ZrC-AO and ZrC-T groups compared to ZrT-AO and ZrT-T, respectively. Mixed failure was the most frequent for the mechanically treated groups, while no cohesive failures were obtained. Conclusion: Lower values of bond strength were obtained for the mechanically treated high-translucent zirconia groups when compared to their conventional zirconia counterparts. Mechanical surface treatment significantly improved the bond strength to conventional and high-translucent zirconia. Clinical significance: Mechanical surface treatment (air-borne particle abrasion or tribochemical treatment) associated with the use of universal adhesives containing MDP could provide a durable bonding to conventional and high-translucent zirconia. Keywords: adhesive cementation; high-translucent zirconia; microtensile bond strength

    Peri-implant tissue management after immediate implant placement using a customized healing abutment

    Full text link
    OBJECTIVE The unavoidable extraction of teeth in the esthetic area can be overcome through different treatment modalities. Recently, immediate implants appeared as a minimally invasive approach to resolving these cases; however, immediate implant loading is not always possible or indicated. In these cases, an innovative approach through customized healing abutments could be used to preserve the soft tissue contour, eliminating the need for reopening surgery and the use of provisional restorations to condition the mucosal contour. CLINICAL CONSIDERATIONS The present cases describe a simplified chairside approach to use customized healing abutments for immediate implants placed after tooth extraction in the anterior and posterior areas in order to maintain the soft tissue contours while reducing the clinical steps until delivering the final restorations. CONCLUSIONS This technique seems to be effective to guide the soft tissue healing around dental implants allowing a natural emergence profile with implant-supported restorations, reducing the number of treatment steps. CLINICAL SIGNIFICANCE The use of customized healing abutments prepares soft tissue for the prosthetic stage preserving its contours and eliminating the need for reopening surgery

    Generation of an induced pluripotent stem cell line (EURACi005-A) from a Parkinson's disease patient carrying a homozygous exon 3 deletion in the PRKNgene

    Get PDF
    Abstract Mutations in the PRKN gene, encoding parkin, are the most frequent known cause of recessive Parkinson's disease (PD). We report the generation of an induced pluripotent stem cell (iPSC) line of a patient carrying a homozygous deletion of exon 3 in the PRKN gene. Skin fibroblasts were reprogrammed using non-integrating episomal plasmids. The generated cell line (EURACi005-A; iPS-2011) exhibits expression of pluripotency markers, the potential to differentiate into all three germ layers, and a stable karyotype. This iPSC line provides a valuable resource for further research on the pathomechanism and drug testing for PRKN-linked PD

    Predictive Value of Pre-Operative 2D and 3D Transthoracic Echocardiography in Patients Undergoing Mitral Valve Repair: Long Term Follow Up of Mitral Valve Regurgitation Recurrence and Heart Chamber Remodeling

    Get PDF
    : The "ideal" management of asymptomatic severe mitral regurgitation (MR) in valve prolapse (MVP) is still debated. The aims of this study were to identify pre-operatory parameters predictive of residual MR and of early and long-term favorable remodeling after MVP repair. We included 295 patients who underwent MV repair for MVP with pre-operatory two- and three-dimensional transthoracic echocardiography (2DTTE and 3DTTE) and 6-months (6M) and 3-years (3Y) follow-up 2DTTE. MVP was classified by 3DTTE as simple or complex and surgical procedures as simple or complex. Pre-operative echo parameters were compared to post-operative values at 6M and 3Y. Patients were divided into Group 1 (6M-MR < 2) and Group 2 (6M-MR ≄ 2), and predictors of MR 2 were investigated. MVP was simple in 178/295 pts, and 94% underwent simple procedures, while in only 42/117 (36%) of complex MVP a simple procedure was performed. A significant relation among prolapse anatomy, surgical procedures and residual MR was found. Post-operative MR ≄ 2 was present in 9.8%: complex MVP undergoing complex procedures had twice the percentage of MR ≄ 2 vs. simple MVP and simple procedures. MVP complexity resulted independent predictor of 6M-MR ≄ 2. Favorable cardiac remodeling, initially found in all cases, was maintained only in MR < 2 at 3Y. Pre-operative 3DTTE MVP morphology identifies pts undergoing simple or complex procedures predicting MR recurrence and favorable cardiac remodeling

    Generation and characterization of three human induced pluripotent stem cell lines (EURACi007-A, EURACi008-A, EURACi009-A) from three different individuals of the same family with arrhythmogenic cardiomyopathy (ACM) carrying the plakophillin2 p.N346Lfs*12 mutation.

    Get PDF
    Abstract Arrhythmogenic Cardiomyopathy (ACM) is a genetically based cardiomyopathy associated with ventricular arrhythmias and fibro-fatty substitution of cardiac tissue. It is characterized by incomplete penetrance. We generated human iPSCs by episomal reprogramming of blood cells from three members of the same family: the proband, affected by ACM and carrying the heterozygous plakophillin2 p.N346Lfs*12 mutation, one asymptomatic carrier of the same mutation and one apparently healthy control. hiPSCs were characterized according to standard protocols including karyotyping, pluripotency marker expression and differentiation towards the three germ layers. These hiPSC lines can be used to study the mechanisms of ACM incomplete penetrance in vitro

    Dental and composite resin discoloration induced by different hydraulic calcium silicate-based cements: two-year in vitro assessment

    Get PDF
    Few long-term studies assess the discoloration induced by hydraulic calcium silicate-based cement on dental structures. In addition, as far as we know, no long-term study has assessed the discoloration induced by these cement on composite resin. Objective: This in vitro study aimed to assess, during a period of two years, the discoloration potential of different hydraulic calcium silicate-based cements (hCSCs) on the enamel/dentin structure and composite resin restoration. Methodology: A total of 40 enamel/dentin discs were obtained from bovine incisors, and 40 composite resin discs (10 mm in diameter × 2 mm thick) were fabricated. A 0.8 mm-deep cavity was made in the center of each disc and filled with the following hCSCs (n=10): Original MTA (Angelus); MTA Repair HP (Angelus); NeoMTA Plus (Avalon); and Biodentine (Septodont). An initial color measurement was performed (T0 - baseline). After 7, 15, 30, 45, 90, 300 days, and two years, new color measurements were performed to determine the color (ΔE00), lightness (ΔL’), chroma (ΔC’), hue differences (ΔH’), and whiteness index (WID). Results: For enamel/dentin, the ΔE00 was significant among groups and periods (p<0.05). NeoMTA Plus had the greatest ΔE00. The NeoMTA Plus group had the greatest ΔE00 after two years for composite resin. Significant reduction in lightness was observed for all groups after two years (p<0.05). The most significant WID values were observed after 30 days for Biodentine (enamel/dentin) and MTA Repair HP groups (composite resin) (p<0.05). Conclusions: The hCSCs changed the colorimetric behavior of both substrates, leading to greater darkening over time. The Bi2O3 in the Original MTA seems relevant in the short periods of color change assessment
    • 

    corecore