18 research outputs found
Impact of COVID-19 on cardiovascular testing in the United States versus the rest of the world
Objectives: This study sought to quantify and compare the decline in volumes of cardiovascular procedures between the United States and non-US institutions during the early phase of the coronavirus disease-2019 (COVID-19) pandemic.
Background: The COVID-19 pandemic has disrupted the care of many non-COVID-19 illnesses. Reductions in diagnostic cardiovascular testing around the world have led to concerns over the implications of reduced testing for cardiovascular disease (CVD) morbidity and mortality.
Methods: Data were submitted to the INCAPS-COVID (International Atomic Energy Agency Non-Invasive Cardiology Protocols Study of COVID-19), a multinational registry comprising 909 institutions in 108 countries (including 155 facilities in 40 U.S. states), assessing the impact of the COVID-19 pandemic on volumes of diagnostic cardiovascular procedures. Data were obtained for April 2020 and compared with volumes of baseline procedures from March 2019. We compared laboratory characteristics, practices, and procedure volumes between U.S. and non-U.S. facilities and between U.S. geographic regions and identified factors associated with volume reduction in the United States.
Results: Reductions in the volumes of procedures in the United States were similar to those in non-U.S. facilities (68% vs. 63%, respectively; p = 0.237), although U.S. facilities reported greater reductions in invasive coronary angiography (69% vs. 53%, respectively; p < 0.001). Significantly more U.S. facilities reported increased use of telehealth and patient screening measures than non-U.S. facilities, such as temperature checks, symptom screenings, and COVID-19 testing. Reductions in volumes of procedures differed between U.S. regions, with larger declines observed in the Northeast (76%) and Midwest (74%) than in the South (62%) and West (44%). Prevalence of COVID-19, staff redeployments, outpatient centers, and urban centers were associated with greater reductions in volume in U.S. facilities in a multivariable analysis.
Conclusions: We observed marked reductions in U.S. cardiovascular testing in the early phase of the pandemic and significant variability between U.S. regions. The association between reductions of volumes and COVID-19 prevalence in the United States highlighted the need for proactive efforts to maintain access to cardiovascular testing in areas most affected by outbreaks of COVID-19 infection
Canagliflozin and renal outcomes in type 2 diabetes and nephropathy
BACKGROUND Type 2 diabetes mellitus is the leading cause of kidney failure worldwide, but few effective long-term treatments are available. In cardiovascular trials of inhibitors of sodium–glucose cotransporter 2 (SGLT2), exploratory results have suggested that such drugs may improve renal outcomes in patients with type 2 diabetes. METHODS In this double-blind, randomized trial, we assigned patients with type 2 diabetes and albuminuric chronic kidney disease to receive canagliflozin, an oral SGLT2 inhibitor, at a dose of 100 mg daily or placebo. All the patients had an estimated glomerular filtration rate (GFR) of 30 to <90 ml per minute per 1.73 m2 of body-surface area and albuminuria (ratio of albumin [mg] to creatinine [g], >300 to 5000) and were treated with renin–angiotensin system blockade. The primary outcome was a composite of end-stage kidney disease (dialysis, transplantation, or a sustained estimated GFR of <15 ml per minute per 1.73 m2), a doubling of the serum creatinine level, or death from renal or cardiovascular causes. Prespecified secondary outcomes were tested hierarchically. RESULTS The trial was stopped early after a planned interim analysis on the recommendation of the data and safety monitoring committee. At that time, 4401 patients had undergone randomization, with a median follow-up of 2.62 years. The relative risk of the primary outcome was 30% lower in the canagliflozin group than in the placebo group, with event rates of 43.2 and 61.2 per 1000 patient-years, respectively (hazard ratio, 0.70; 95% confidence interval [CI], 0.59 to 0.82; P=0.00001). The relative risk of the renal-specific composite of end-stage kidney disease, a doubling of the creatinine level, or death from renal causes was lower by 34% (hazard ratio, 0.66; 95% CI, 0.53 to 0.81; P<0.001), and the relative risk of end-stage kidney disease was lower by 32% (hazard ratio, 0.68; 95% CI, 0.54 to 0.86; P=0.002). The canagliflozin group also had a lower risk of cardiovascular death, myocardial infarction, or stroke (hazard ratio, 0.80; 95% CI, 0.67 to 0.95; P=0.01) and hospitalization for heart failure (hazard ratio, 0.61; 95% CI, 0.47 to 0.80; P<0.001). There were no significant differences in rates of amputation or fracture. CONCLUSIONS In patients with type 2 diabetes and kidney disease, the risk of kidney failure and cardiovascular events was lower in the canagliflozin group than in the placebo group at a median follow-up of 2.62 years
Bomba sangüínea espiral: concepção, desenvolvimento e aplicação clínica de projeto original
INTRODUÇÃO: O trabalho aborda projeto original relativo à concepção, ao desenvolvimento e à aplicação clínica de bomba sangüínea que associa forças centrífuga e axial de propulsão hidráulica, baseada no princípio de Arquimedes, denominada Bomba Espiral (BE), tendo recebido Patente Nacional e Relatório Preliminar Internacional categorizando-a como invento. MÉTODO: Visa avaliar sua capacidade hidrodinâmica e seu impacto aos elementos figurados do sangue por meio de testes "in vitro", como Eficiência Hidrodinâmica, Hemólise Normalizada e Visibilização de Escoamento, e, nos testes "in vivo" experimentais, feitos em carneiros submetidos a Circulação Extracorpórea (CEC), e clínico, em 43 pacientes submetidos a operações cardíacas com CEC, nas quais o elemento propulsor foi a BE. RESULTADOS: Na dependência da distância entre o rotor e a carcaça (fenda) da bomba pôde-se observar que com 1,5 mm gerou escoamento ao redor de 9 L/min, pressão acima de 400mmHg com 1500 rotações por minuto (rpm), índices de Hemólise Normalizada não superiores a 0,0375 g/100l em condições de alto fluxo e pressão, e pelo estudo de Visibilização do Escoamento no interior da bomba não se detectou áreas de estagnação ou turbulência na entrada, saída e junto à extremidade dos fusos. Nas pesquisas "in vivo" experimentais em ovinos em CEC por 6 horas a BE foi capaz de manter parâmetros pressóricos adequados e Hemoglobina Livre entre 16,36 mg% e 44,90 mg%. Durante sua aplicação em cirurgias cardíacas com CEC, num grupo de 43 pacientes, pôde-se constatar variações pré e pós-CEC, na Hemoglobina Livre de 9,34 a 44,16 mg%, no Fibrinogênio, de 236,65 a 547,26 mg%, na contagem do número de Plaquetas de 152,465 a 98,139, Desidrogenase Láctica, de 238,12 a 547,26 mg%, com tempo de coagulação ativada ao redor de 800 seg. quando em CEC. CONCLUSÕES: A BE mostrou resolutividade por gerar escoamento e pressão adequados, sem causar danos excessivos aos elementos figurados do sangue
CLINICAL EVALUATION OF THE SPIRAL PUMP® AFTER IMPROVINGS TO THE ORIGINAL PROJECT IN PATIENTS SUBMITTED TO CARDIAC SURGERIES WITH CARDIO PULMONARY BY PASS
Objective: The objective of this paper is to present the results from Spiral Pump clinical trial after design modifications performed at its previous project. This pump applies axial end centrifugal hydraulic effects for blood pumping during cardiopulmonary bypass for patients under cardiac surgery. Methods: This study was performed in 52 patients (51% males), between 20 to 80 (67±14.4) years old weighing 53 to 102 (71.7±12.6) kg, mostly under myocardial revascularization surgery (34.6%) and valvular surgery (32.8%). Besides the routine evaluation of the data observed in these cases, we monitored pump rotational speed, blood flow, cardiopulmonary bypass duration, urine free hemoglobin for blood cell trauma analysis (+ to 4+), lactate desidrogenase (UI/L), fibrinogen level (mg/dL) and platelet count (nº/mm3). Results: Besides maintaining appropriate blood pressure and metabolic parameters it was also observed that the Free Hemoglobin levels remained normal, with a slight increase after 90 minutes of cardiopulmonary bypass. The Lactate Dehydrogenase showed an increase, with medians varying between 550-770 IU/L, whereas the decrease in Fibrinogen showed medians of 130-100 mg/dl. The number of platelets showed a slight decrease with the medians ranging from 240,000 to 200,000/mm3. No difficulty was observed during perfusion terminations, nor were there any immediate deaths, and all patients except one, were discharged in good condition. CONCLUSION: The Spiral Pump, as blood propeller during cardiopulmonary bypass, demonstrated to be reliable and safe, comprising in a good option as original and national product for this kind of application
Association of high post-transplant soluble CD30 serum levels with, chronic allograft nephropathy
The purpose of this study was to evaluate the association of post-transplant soluble CD30 (sCD30) levels, isolated or in combination with of anti-HLA class II antibodies and of serum creatinine levels, with kidney graft loss due to chronic allograft nephropathy (CAN), and type of lesions in graft biopsies for cause. the study comprised 511 first kidney graft recipients, transplanted at a single center, with a graft functioning for at least 2.8 years. A single blood sample was collected from each patient sCD30 levels were determined by ELISA, and HIA antibodies by Luminex assay. the minimum follow-up after testing was 93 years. High sCD30 levels, set at sCD30 >= 3.415 ng/mL, the presence of HLA class II antibodies, and serum creatinine >= 1.9 mg/dL were independently associated with CAN-graft loss (P values <0.0001, 0.05, <0.0001, respectively), and the combined hazard ratio for CAN-graft loss was 20.2. Analyses of 166 biopsies for cause showed that high sCD30 levels and creatinine were independently associated with interstitial lesions. Post-transplant sCD30 serum levels, especially in conjunction with information regarding HLA class II antibodies and serum creatinine levels, provide valuable information regarding graft outcome and could be useful for the management of kidney transplant recipients. (C) 2013 Elsevier B.V. All rights reserved.Associacao Fundo de Incentivo a Pesquisa (AFIP)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)AFIP, Inst Immunogenet, BR-04040031 São Paulo, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilHosp Rim & Hipertensao, São Paulo, BrazilUniv Fed Parana, BR-80060000 Curitiba, PR, BrazilUniversidade Federal de São Paulo, São Paulo, BrazilFAPESP: 2008/56110-0Web of Scienc
NEOTROPICAL CARNIVORES: a data set on carnivore distribution in the Neotropics
Mammalian carnivores are considered a key group in maintaining ecological health and can indicate potential ecological integrity in landscapes where they occur. Carnivores also hold high conservation value and their habitat requirements can guide management and conservation plans. The order Carnivora has 84 species from 8 families in the Neotropical region: Canidae; Felidae; Mephitidae; Mustelidae; Otariidae; Phocidae; Procyonidae; and Ursidae. Herein, we include published and unpublished data on native terrestrial Neotropical carnivores (Canidae; Felidae; Mephitidae; Mustelidae; Procyonidae; and Ursidae). NEOTROPICAL CARNIVORES is a publicly available data set that includes 99,605 data entries from 35,511 unique georeferenced coordinates. Detection/non-detection and quantitative data were obtained from 1818 to 2018 by researchers, governmental agencies, non-governmental organizations, and private consultants. Data were collected using several methods including camera trapping, museum collections, roadkill, line transect, and opportunistic records. Literature (peer-reviewed and grey literature) from Portuguese, Spanish and English were incorporated in this compilation. Most of the data set consists of detection data entries (n = 79,343; 79.7%) but also includes non-detection data (n = 20,262; 20.3%). Of those, 43.3% also include count data (n = 43,151). The information available in NEOTROPICAL CARNIVORES will contribute to macroecological, ecological, and conservation questions in multiple spatio-temporal perspectives. As carnivores play key roles in trophic interactions, a better understanding of their distribution and habitat requirements are essential to establish conservation management plans and safeguard the future ecological health of Neotropical ecosystems. Our data paper, combined with other large-scale data sets, has great potential to clarify species distribution and related ecological processes within the Neotropics. There are no copyright restrictions and no restriction for using data from this data paper, as long as the data paper is cited as the source of the information used. We also request that users inform us of how they intend to use the data
Reduction of cardiac imaging tests during the COVID-19 pandemic: The case of Italy. Findings from the IAEA Non-invasive Cardiology Protocol Survey on COVID-19 (INCAPS COVID)
Background: In early 2020, COVID-19 massively hit Italy, earlier and harder than any other European country. This caused a series of strict containment measures, aimed at blocking the spread of the pandemic. Healthcare delivery was also affected when resources were diverted towards care of COVID-19 patients, including intensive care wards. Aim of the study: The aim is assessing the impact of COVID-19 on cardiac imaging in Italy, compare to the Rest of Europe (RoE) and the World (RoW). Methods: A global survey was conducted in May–June 2020 worldwide, through a questionnaire distributed online. The survey covered three periods: March and April 2020, and March 2019. Data from 52 Italian centres, a subset of the 909 participating centres from 108 countries, were analyzed. Results: In Italy, volumes decreased by 67% in March 2020, compared to March 2019, as opposed to a significantly lower decrease (p < 0.001) in RoE and RoW (41% and 40%, respectively). A further decrease from March 2020 to April 2020 summed up to 76% for the North, 77% for the Centre and 86% for the South. When compared to the RoE and RoW, this further decrease from March 2020 to April 2020 in Italy was significantly less (p = 0.005), most likely reflecting the earlier effects of the containment measures in Italy, taken earlier than anywhere else in the West. Conclusions: The COVID-19 pandemic massively hit Italy and caused a disruption of healthcare services, including cardiac imaging studies. This raises concern about the medium- and long-term consequences for the high number of patients who were denied timely diagnoses and the subsequent lifesaving therapies and procedures