18 research outputs found
Remote monitoring of patients with implantable cardioverter-defibrillators: Can results from large clinical trials be transposed to clinical practice?
SummaryBackgroundRemote monitoring (RM) is increasingly used to follow up patients with implantable cardioverter-defibrillators (ICDs). Randomized control trials provide evidence for the benefit of this intervention, but data for RM in daily clinical practice with multiple-brands and unselected patients is lacking.AimsTo assess the effect of RM on patient management and clinical outcome for recipients of ICDs in daily practice.MethodsWe reviewed ICD recipients followed up at our institution in 2009 with RM or with traditional hospital only (HO) follow-up. We looked at the effect of RM on the number of scheduled ambulatory follow-ups and urgent unscheduled consultations, the time between onset of asymptomatic events to clinical intervention and the clinical effectiveness of all consultations. We also evaluated the proportion of RM notifications representing clinically relevant situations.ResultsWe included 355 patients retrospectively (RM: n=144, HO: n=211, 76.9% male, 60.3±15.2years old, 50.1% with ICDs for primary prevention and mean left ventricular ejection fraction 35.5±14.5%). Average follow-up was 13.5months. The RM group required less scheduled ambulatory follow-up consultations (1.8 vs. 2.1/patient/year; P<0.0001) and a far lower median time between the onset of asymptomatic events and clinical intervention (7 vs. 76days; P=0.016). Of the 784 scheduled ambulatory follow-up consultations carried out, only 152 (19.4%) resulted in therapeutic intervention or ICD reprogramming. We also found that the vast majority of RM notifications (61.9%) were of no clinical relevance.ConclusionRM allows early management of asymptomatic events and a reduction in scheduled ambulatory follow-up consultations in daily clinical practice, without compromising safety, endorsing RM as the new standard of care for ICD recipients
Peut-on identifier des facteurs pronostiques de survenue d'événements rythmiques graves chez les patients atteints d'une dysplasie arythmogène du ventricule droit?
LILLE2-BU Santé-Recherche (593502101) / SudocSudocFranceF
LE MONITEUR ELECTROCARDIOGRAPHIQUE IMPLANTABLE (UN NOUVEL OUTIL DANS L'APPROCHE DIAGNOSTIQUE DES SYNCOPES INEXPLIQUEES : EXPERIENCE INITIALE A PROPOS DE 33 OBSERVATIONS)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
Risque rythmique selon l'évolution de la fraction d'éjection ventriculaire gauche dans les cardiomyopathies dilatées non ischémiques (étude rétrospective à partir de 93 cas porteurs d'un défibrillateur automatique)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
Le taux de BNP à l'implantation est-il prédictif d'événements rythmiques chez des patients implantés d'un défibrillateur en prévention secondaire ? (à propos de 240 patients)
LILLE2-BU Santé-Recherche (593502101) / SudocSudocFranceF
L étude de la variabilité de fréquence cardiaque chez le patient insuffisant cardiaque resynchronisé peut-elle avoir un intérêt pronostique ? (étude préliminaire de 34 patients)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
La dysfonction ventriculaire droite influence-t-elle le pronostic rythmique des patients porteurs d'un défibrillateur automatique implantable ? (étude prospective de 173 patients)
LILLE2-BU Santé-Recherche (593502101) / SudocPARIS-BIUM (751062103) / SudocSudocFranceF
Evaluation rétrospective du risque rythmique dans la cardiomyopathie hypertrophique (l'expérience lilloise entre 2000 et 2010)
LILLE2-BU Santé-Recherche (593502101) / SudocSudocFranceF