25 research outputs found

    Treatment of femoral neck fractures in elderly patients over 60 years of age - which is the ideal modality of primary joint replacement?

    Get PDF
    BACKGROUND: Femoral neck fractures in the elderly are frequent, represent a great health care problem, and have a significant impact on health insurance costs. Reconstruction options using hip arthroplasty include unipolar or bipolar hemiarthroplasty (HA), and total hip arthroplasty (THA). The purpose of this review is to discuss the indications, limitations, and pitfalls of each of these techniques. METHODS: The Pubmed database was searched for all articles on femoral neck fracture and for the reconstruction options presented in this review using the search terms "femoral neck fracture", "unipolar hemiarthroplasty", "bipolar hemiarthroplasty", and "total hip arthroplasty". In addition, cross-referencing was used to cover articles eventually undetected by the respective search strategies. The resulting articles were then reviewed with regard to the different techniques, outcome and complications of the distinct reconstruction options. RESULTS: THA yields the best functional results in patients with displaced femoral neck fractures with complication rates comparable to HA. THA is beneficially implanted using an anterior approach exploiting the internervous plane between the tensor fasciae latae and the sartorius muscles allowing for immediate full weight-bearing. Based on our findings, bipolar hemiarthroplasty, similar to unipolar hemiarthroplasty, cannot restorate neither anatomical nor biomechanical features of the hip joint. Therefore, it can only be recommended as a second line of defense-procedure for patients with low functional demands and limited live expectancy. CONCLUSIONS: THA is the treatment of choice for femoral neck fractures in patients older than 60 years. HA should only be implanted in patients with limited life expectanc

    Gastrocnemius muscle herniation as a rare differential diagnosis of ankle sprain: case report and review of the literature

    Get PDF
    BACKGROUND: Muscle herniation of the leg is a rare clinical entity. Yet, knowing this condition is necessary to avoid misdiagnosis and delayed treatment. In the extremities, muscle herniation most commonly occurs as a result of an acquired fascial defect, often due to trauma. Different treatment options for symptomatic extremity muscle herniation in the extremities, including conservative treatment, fasciotomy and mesh repair have been described. CASE PRESENTATION: We present the case of a patient who presented with prolonged symptoms after an ankle sprain. The clinical picture showed a fascial insufficiency with muscle bulging under tension. Ultrasound and MRI imaging confirmed the diagnosis of muscle hernia of the medial gastrocnemius on the right leg. Conservative treatment did not lead to success. Therefore, the fascial defect was treated surgically by repairing the muscle herniation using a synthetic vicryl propylene patch. CONCLUSIONS: Muscle hernias should be taken into consideration as a rare differential diagnosis whenever patients present with persisting pain or soft tissue swelling after ankle sprain. Diagnosis is mainly based on clinical aspect and physical examination, but can be confirmed by radiologic imaging techniques, including (dynamic) ultrasound and MRI. If conservative treatment fails, we recommend the closure with mesh patches for large fascial defects

    Cement-augmented dorsal instrumentation of the spine as a safe adjunct to the multimodal management of metastatic pheochromocytoma: a case report

    Get PDF
    Malignant pheochromocytoma is a neuroendocrine tumor that originates from chromaffin tissue. Although osseous metastases are common, metastatic dissemination to the spine rarely occurs

    Is the Internal Rotation Lag Sign a Sensitive Test for Detecting Hip Abductor Tendon Ruptures after Total Hip Arthroplasty?

    Get PDF
    INTRODUCTION: Total hip arthroplasty (THA) is one of the most frequently performed procedures in orthopaedics and weakness of external rotators is often recognized thereafter. However, the etiology of lateral hip pain is multifaceted. For the diagnosis of abductor tendon rupture, magnetic resonance imaging (MRI) is the gold standard. As not every patient can be subjected to MRI, a clinical diagnostic test for easy detection of lesions of the abductor tendon is missing. Here, we present the internal rotation lack sign indicating abductor tendon pathology. METHODS: The patient is placed in lateral position on a stretcher with hips and knees in neutral position. The knee is flexed to 45° and the hip passively abducted and elevated by the investigator. With the foot passively abducted, the patient is then asked to bring his knee in direction to the examination table. This motion is also tested passively. The test is regarded positive, if no internal rotation is possible and/or if this is painful. If groin pain is elicited during either of the exercises, the test is also rated positive. RESULTS: We evaluated this test in 20 patients clinically and by magnetic resonance imaging (MRI). All patients demonstrated a positive internal rotation lag sign. Twelve of them lag of internal rotation and evidence of anterior abductor tendon rupture on MRI, 8 with lag of internal rotation and no evidence of abductor tendon rupture. CONCLUSION: The new clinical diagnostic sign presented here may improve the diagnosis of abductor tendon rupture in the future.Level of Evidence: Diagnostic study, level I

    Mechanical testing of a device for subcutaneous internal anterior pelvic ring fixation versus external pelvic ring fixation

    Get PDF
    BACKGROUND: Although useful in the emergency treatment of pelvic ring injuries, external fixation is associated with pin tract infections, the patient’s limited mobility and a restricted surgical accessibility to the lower abdomen. In this study, the mechanical stability of a subcutaneous internal anterior fixation (SIAF) system is investigated. METHODS: A standard external fixation and a SIAF system were tested on pairs of Polyoxymethylene testing cylinders using a universal testing machine. Each specimen was subjected to a total of 2000 consecutive cyclic loadings at 1 Hz with sinusoidal lateral compression/distraction (+/−50 N) and torque (+/− 0.5 Nm) loading alternating every 200 cycles. Translational and rotational stiffness were determined at 100, 300, 500, 700 and 900 cycles. RESULTS: There was no significant difference in translational stiffness between the SIAF and the standard external fixation when compared at 500 (p = .089), 700 (p = .081), and 900 (p = .266) cycles. Rotational stiffness observed for the SIAF was about 50 percent higher than the standard external fixation at 300 (p = .005), 500 (p = .020), and 900 (p = .005) cycles. No loosening or failure of the rod-pin/rod-screw interfaces was seen. CONCLUSIONS: In comparison with the standard external fixation system, the tested device for subcutaneous internal anterior fixation (SIAF) in vitro has similar translational and superior rotational stiffness

    Correlation of psychomotor findings and the ability to partially weight bear

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Partial weight bearing is thought to avoid excessive loading that may interfere with the healing process after surgery of the pelvis or the lower extremity. The object of this study was to investigate the relationship between the ability to partially weight bear and the patient's psychomotor skills and an additional evaluation of the possibility to predict this ability with a standardized psychomotor test.</p> <p>Methods</p> <p>50 patients with a prescribed partial weight bearing at a target load of 15 kg following surgery were verbally instructed by a physical therapist. After the instruction and sufficient training with the physical therapist vertical ground reaction forces using matrix insoles were measured while walking with forearm crutches. Additionally, psychomotor skills were tested with the Motorische Leistungsserie (MLS). To test for correlations Spearman's Rank correlation was used. For further comparison of the two groups a Mann-Withney test was performed using Bonferroni correction.</p> <p>Results</p> <p>The patient's age and body weight significantly correlated with the ability to partially weight bear at a 15 kg target load. There were significant correlations between several subtests of the MLS and ground reaction forces measured while walking with crutches. Patients that were able to correctly perform partial weight bearing showed significant better psychomotor skills especially for those subtests where both hands had to be coordinated simultaneously.</p> <p>Conclusions</p> <p>The ability to partially weight bear is associated with psychomotor skills. The MLS seems to be a tool that helps predicting the ability to keep within the prescribed load limits.</p

    Traumatic atlantoaxial rotatory subluxation in an adolescent: a case report

    Get PDF
    Atlantoaxial rotatory subluxation is rarely caused by trauma in adults. Usually, the treatment of choice is traction using Halo/Gardner-Wells fixation devices for up to six weeks. CASE PRESENTATION: We present the case of a 19-year-old Caucasian woman with traumatic atlantoaxial subluxation. Early reduction three hours after trauma and immobilization using only a soft collar were performed and yielded very good clinical results. CONCLUSION: In the adult population, atlantoaxial subluxation is a rare condition but is severe if untreated. Early treatment implies a non-surgical approach and a good outcome. Conservative treatment is the recommended first step for this condition
    corecore