6,741 research outputs found

    Design, Construction, Operation and Performance of a Hadron Blind Detector for the PHENIX Experiment

    Full text link
    A Hadron Blind Detector (HBD) has been developed, constructed and successfully operated within the PHENIX detector at RHIC. The HBD is a Cherenkov detector operated with pure CF4. It has a 50 cm long radiator directly coupled in a window- less configuration to a readout element consisting of a triple GEM stack, with a CsI photocathode evaporated on the top surface of the top GEM and pad readout at the bottom of the stack. This paper gives a comprehensive account of the construction, operation and in-beam performance of the detector.Comment: 51 pages, 39 Figures, submitted to Nuclear Instruments and Method

    Strong extinction of a far-field laser beam by a single quantum dot

    Full text link
    Through the utilization of index-matched GaAs immersion lens techniques we demonstrate a record extinction (12%) of a far-field focused laser by a single InAs/GaAs quantum dot. This contrast level enables us to report for the first time resonant laser transmission spectroscopy on a single InAs/GaAs quantum dot without the need for phase-sensitive lock-in detection

    Feasibility and Cardiac Safety of Trastuzumab Emtansine After Anthracycline-Based Chemotherapy As (neo) Adjuvant Therapy for Human Epidermal Growth Factor Receptor 2-Positive Early-Stage Breast Cancer

    Get PDF
    Purpose Trastuzumab emtansine (T-DM1), an antibody-drug conjugate comprising the cytotoxic agent DM1, a stable linker, and trastuzumab, has demonstrated substantial activity in human epidermal growth factor receptor 2 (HER2) -positive metastatic breast cancer, raising interest in evaluating the feasibility and cardiac safety of T-DM1 in early-stage breast cancer (EBC). Patients and Methods Patients (N = 153) with HER2-positive EBC and prechemotherapy left ventricular ejection fraction (LVEF) \u3e= 55% received (neo) adjuvant doxorubicin plus cyclophosphamide or fluorouracil plus epirubicin plus cyclophosphamide followed by T-DM1 for four cycles. Patients could then receive three to four cycles of optional docetaxel with or without trastuzumab. T-DM1 was then resumed with optional radiotherapy (sequential or concurrent) for 1 year (planned) of HER2-directed therapy. The coprimary end points were rate of prespecified cardiac events and safety. Results Median follow-up was 24.6 months. No prespecified cardiac events or symptomatic congestive heart failures were reported. Four patients (2.7%) had asymptomatic LVEF declines (\u3e= 10 percentage points from baseline to LVEF\u3c 50%), leading to T-DM1 discontinuation in one patient. Of 148 patients who received \u3e= one cycle of T-DM1, 82.4% completed the planned 1-year duration of HER2-directed therapy. During T-DM1 treatment, 38.5% and 2.7% of patients experienced grade 3 and 4 adverse events, respectively. Approximately 95% of patients receiving T-DM1 plus radiotherapy completed \u3e= 95% of the planned radiation dose with dela

    Power grip, pinch grip, manual muscle testing or thenar atrophy - which should be assessed as a motor outcome after carpal tunnel decompression? A systematic review

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Objective assessment of motor function is frequently used to evaluate outcome after surgical treatment of carpal tunnel syndrome (CTS). However a range of outcome measures are used and there appears to be no consensus on which measure of motor function effectively captures change. The purpose of this systematic review was to identify the methods used to assess motor function in randomized controlled trials of surgical interventions for CTS. A secondary aim was to evaluate which instruments reflect clinical change and are psychometrically robust.</p> <p>Methods</p> <p>The bibliographic databases Medline, AMED and CINAHL were searched for randomized controlled trials of surgical interventions for CTS. Data on instruments used, methods of assessment and results of tests of motor function was extracted by two independent reviewers.</p> <p>Results</p> <p>Twenty-two studies were retrieved which included performance based assessments of motor function. Nineteen studies assessed power grip dynamometry, fourteen studies used both power and pinch grip dynamometry, eight used manual muscle testing and five assessed the presence or absence of thenar atrophy. Several studies used multiple tests of motor function. Two studies included both power and pinch strength and reported descriptive statistics enabling calculation of effect sizes to compare the relative responsiveness of grip and pinch strength within study samples. The study findings suggest that tip pinch is more responsive than lateral pinch or power grip up to 12 weeks following surgery for CTS.</p> <p>Conclusion</p> <p>Although used most frequently and known to be reliable, power and key pinch dynamometry are not the most valid or responsive tools for assessing motor outcome up to 12 weeks following surgery for CTS. Tip pinch dynamometry more specifically targets the thenar musculature and appears to be more responsive. Manual muscle testing, which in theory is most specific to the thenar musculature, may be more sensitive if assessed using a hand held dynamometer – the Rotterdam Intrinsic Handheld Myometer. However further research is needed to evaluate its reliability and responsiveness and establish the most efficient and psychometrically robust method of evaluating motor function following surgery for CTS.</p

    Run 2 Upgrades to the CMS Level-1 Calorimeter Trigger

    Get PDF
    The CMS Level-1 calorimeter trigger is being upgraded in two stages to maintain performance as the LHC increases pile-up and instantaneous luminosity in its second run. In the first stage, improved algorithms including event-by-event pile-up corrections are used. New algorithms for heavy ion running have also been developed. In the second stage, higher granularity inputs and a time-multiplexed approach allow for improved position and energy resolution. Data processing in both stages of the upgrade is performed with new, Xilinx Virtex-7 based AMC cards.Comment: 10 pages, 7 figure
    • …
    corecore