    Smart Textile Based on Fiber Bragg Grating Sensors for Respiratory Monitoring: Design and Preliminary Trials.

    Get PDF
    Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations.Continuous respiratory monitoring is important to assess adequate ventilation. We present a fiber optic-based smart textile for respiratory monitoring able to work during Magnetic Resonance (MR) examinations. The system is based on the conversion of chest wall movements into strain of two fiber Bragg grating (FBG) sensors, placed on the upper thorax (UT). FBGs are glued on the textile by an adhesive silicon rubber. To increase the system sensitivity, the FBGs positioning was led by preliminary experiments performed using an optoelectronic system: FBGs placed on the chest surface experienced the largest strain during breathing. System performances, in terms of respiratory period (TR), duration of inspiratory (TI) and expiratory (TE) phases, as well as left and right UT volumes, were assessed on four healthy volunteers. The comparison of results obtained by the proposed system and an optoelectronic plethysmography highlights the high accuracy in the estimation of TR, TI, and TE: Bland-Altman analysis shows mean of difference values lower than 0.045 s, 0.33 s, and 0.35 s for TR, TI, and TE, respectively. The mean difference of UT volumes between the two systems is about 8.3%. The promising results foster further development of the system to allow routine use during MR examinations

    Sugli esordi di Alberto Moravia, romanziere e saggista (1926-1927)

    No full text
    Il contributo ricostruisce - sulla base di documenti in buona parte inediti - la genesi dei primi due saggi critici di Alberto Moravia, composti entrambi nell'ottobre del 1926. Il primo saggio, dedicato all'opera di James Joyce, si riteneva perduto ed è invece stato individuato su « Il Quarto Stato », il settimanale milanese diretto da Pietro Nenni e Carlo Rosselli ; il secondo, dedicato alla “crisi" del Romanzo, fu spedito al direttore de « La Fiera letteraria » Umberto Fracchia nell'autunno del 1926 ma pubblicato su quella rivista - per ragioni che qui si tenta di comprendere - solo nell'ottobre del 1927. In appendice vengono trascritti nella loro integrità i testi dei due saggi

    Physycal Exercise And Multiple Sclerosis: Effects On Inflammatory Index

    No full text

    Double-pion production by high-energy neutrinos

    No full text
    • …
    corecore