352 research outputs found

    Statistical analysis of IMRT dosimetry quality assurance measurements for local delivery guideline

    Get PDF
    <p>Abstract</p> <p>Purpose</p> <p>To establish our institutional guideline for IMRT delivery, we statistically evaluated the results of dosimetry quality assurance (DQA) measurements and derived local confidence limits using the concept confidence limit of |mean|+1.96Ļƒ.</p> <p>Materials and methods</p> <p>From June 2006 to March 2009, 206 patients with head and neck cancer, prostate cancer, liver cancer, or brain tumor were treated using LINAC-based IMRT technique. In order to determine site specific DQA tolerances at a later stage, a hybrid plan with the same fluence maps as in the treatment plan was generated on CT images of a cylindrical phantom of acryl. Points of measurement using a 0.125 cm<sup>3 </sup>ion-chamber were typically located in the region of high and uniform doses. The planar dose distributions perpendicular to the central axis were measured by using a diode array in solid water with all fields delivered, and assessed using gamma criteria of 3%/3 mm. The mean values and standard deviations were used to develop the local confidence and tolerance limits. The dose differences and gamma pass rates for the different treatment sites were also evaluated in terms of total monitor uints (MU), MU/cGy, and the number of PTV's pieces.</p> <p>Results</p> <p>The mean values and standard deviations of ion-chamber dosimetry differences between calculated and measured doses were -1.6 Ā± 1.2% for H&N cancer, -0.4 Ā± 1.2% for prostate and abdominal cancer, and -0.6 Ā± 1.5% for brain tumor. Most of measured doses (92.2%) agreed with the calculated doses within a tolerance limit of Ā±3% recommended in the literature. However, we found some systematic under-dosage for all treatment sites. The percentage of points passing the gamma criteria, averaged over all treatment sites was 97.3 Ā± 3.7%. The gamma pass rate and the agreement of ion-chamber dosimetry generally decreased with increasing the number of PTV's pieces, the degree of modulation (MU/cGy), and the total MU beyond 700. Our local confidence limits were comparable to those of AAPM TG 119 and ESTRO guidelines that were provided as a practical baseline for center-to-center commissioning comparison. Thus, our institutional confidence and action limits for IMRT delivery were set into the same levels of those guidelines.</p> <p>Discussion and Conclusions</p> <p>The systematic under-dosage were corrected by tuning up the MLC-related factors (dosimetric gap and transmission) in treatment planning system (TPS) and further by incorporating the tongue-and groove effect into TPS. Institutions that have performed IMRT DQA measurements over a certain period of time need to analyze their accrued DQA data. We confirmed the overall integrity of our IMRT system and established the IMRT delivery guideline during this procedure. Dosimetric corrections for the treatment plans outside of the action level can be suggested only with such rigorous DQA and statistical analysis.</p

    Wall-Eyed Monocular Internuclear Ophthalmoplegia (WEMINO) with Contraversive Ocular Tilt Reaction

    Get PDF
    Wall-eyed monocular internuclear ophthalmoplegia (WEMINO) with contraversive ocular tilt reaction has not been previously reported. A 71-year-old woman suddenly developed blurred vision. Examination revealed left internuclear ophthalmoplegia, left exotropia, right hypotropia, and rightward head tilt. Magnetic resonance imaging showed a tiny infarction at the area of the left medial longitudinal fasciculus in the upper pons. WEMINO with contraversive ocular tilt reaction may be caused by a paramedian pontine tegmental infarction that selectively involves the medial longitudinal fasciculus

    Assessment of dose perturbations for metal stent in photon and proton radiotherapy plans for hepatocellular carcinoma

    Get PDF
    Background : The present study aimed to investigate the dosimetric impact of metal stent for photon and proton treatment plans in hepatocellular carcinoma. Methods : With computed tomography data of a water-equivalent solid phantom, dose perturbation caused by a metal stent included in the photon and proton treatment of hepatocellular carcinoma was evaluated by comparing Eclipse and RayStation treatment planning system (TPS) to a Monte Carlo (MC) based dose calculator. Photon and proton plans were created with anteriorā€“posterior/posterior-anterior (AP/PA) fields using a 6 MV beam and AP/PA fields of a wobbling beam using 150Ā MeV and a 10Ā cm ridge filter. The difference in dose distributions and dosimetric parameters were compared depending on the stent's positions (the bile duct (GB) and intestinal tract (GI)) and angles (0Ā°, 45Ā°, and 90Ā°). Additionally, the dose variation in the target volume including the stent was comparatively evaluated through dose volume histogram (DVH) analysis. And the comparison of clinical cases was carried out in the same way. Results : Percentage differences in the dosimetric parameters calculated by MC ranged fromā€‰āˆ’ā€‰7.0 to 3.9% for the photon plan andā€‰āˆ’ā€‰33.7 to 4.3% for the proton plan, depending on the angle at which the GB and GI stents were placed, compared to those without the stent. The maximum difference was observed at the minimum dose (Dmin), which was observed in both photon and proton plans in the GB and GI stents deployed at a 90Ā° incidence angle. The parameter differences were greater in the proton plan than in photon plan. The target volume showed various dose variations depending on positions and angles of stent for both beams. Compared with no-stent, the doses within the target volume containing the GI and GB stents for the photon beam were overestimated in the high-dose area at 0Ā°, nearly equal within 1% at 45Ā°, and underestimated at 90Ā°. These doses to the proton beam were underestimated at all angles, and the amount of underdose to the target volume increased with an increase in the stent angle. However, the difference was significantly greater with the proton plan than the photon plan. Conclusions : Dose perturbations within the target volume due to the presence of the metal stent were not observed in the TPS calculations for photon and proton beams, but MC was used to confirm that there are dose variations within the target volume. The MC results found that delivery of the treatment beam avoiding the stent was the best method to prevent target volume underdose.This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (No. 2022R1C1C1006840 and No.2022R1F1A1072199)

    A Family Harboring CMT1A Duplication and HNPP Deletion

    Get PDF
    Charcot-Marie-Tooth disease type 1A (CMT1A) is associated with duplication of chromosome 17p11.2-p12, whereas hereditary neuropathy with liability to pressure palsies (HNPP), which is an autosomal dominant neuropathy showing characteristics of recurrent pressure palsies, is associated with 17p11.2-p12 deletion. An altered gene dosage of PMP22 is believed to the main cause underlying the CMT1A and HNPP phenotypes. Although CMT1A and HNPP are associated with the same locus, there has been no report of these two mutations within a single family. We report a rare family harboring CMT1A duplication and HNPP deletion

    Genome-Scale Profiling and High-Throughput Analyses Unravel the Genetic Basis of Arsenic Content Variation in Rice

    Get PDF
    Ionomics, the study of the composition of mineral nutrients and trace elements in organisms that represent the inorganic component of cells and tissues, has been widely studied to explore to unravel the molecular mechanism regulating the elemental composition of plants. However, the genetic factors of rice subspecies in the interaction between arsenic and functional ions have not yet been explained. Here, the correlation between As and eight essential ions in a rice core collection was analyzed, taking into account growing condition and genetic factors. The results demonstrated that the correlation between As and essential ions was affected by genetic factors and growing condition, but it was confirmed that the genetic factor was slightly larger with the heritability for arsenic content at 53%. In particular, the cluster coefficient of japonica (0.428) was larger than that of indica (0.414) in the co-expression network analysis for 23 arsenic genes, and it was confirmed that the distance between genes involved in As induction and detoxification of japonica was far than that of indica. These findings provide evidence that japonica populations could accumulate more As than indica populations. In addition, the cis-eQTLs of AIR2 (arsenic-induced RING finger protein) were isolated through transcriptome-wide association studies, and it was confirmed that AIR2 expression levels of indica were lower than those of japonica. This was consistent with the functional haplotype results for the genome sequence of AIR2, and finally, eight rice varieties with low AIR2 expression and arsenic content were selected. In addition, As-related QTLs were identified on chromosomes 5 and 6 under flooded and intermittently flooded conditions through genome-scale profiling. Taken together, these results might assist in developing markers and breeding plans to reduce toxic element content and breeding high-quality rice varieties in future

    Extensive Systemic Sarcoidosis with Testicular Involvement Mimicking Metastatic Testicular Cancer

    Get PDF
    Sarcoidosis is an idiopathic, multisystem disease that rarely involves the genitourinary tract. Here we present an unusual case of testicular sarcoidosis with extensive lymphadenopathy that mimicked a metastatic testicular tumor. A 27-year-old male presented with a palpable right testicular mass accompanied by multiple palpable inguinal lymph nodes. The scrotal ultrasound showed a hypoechoic lesion at the inferior portion of the right testis. Extensive enlarged lymph nodes were noted in multiple areas on the abdominal computed tomography. Preoperative testicular tumor markers were within the normal range. Exploration of the right testis with a frozen section analysis of the right testicular mass and of a palpable right inguinal lymph node showed granulomatous inflammation. The testis was salvaged and the final pathological diagnosis was sarcoidosis. Treatment with high-dose corticosteroids resulted in complete resolution of the intratesticular mass and a significant decrease in the extent of the lymphadenopathy
    • ā€¦
    corecore