395 research outputs found

    Electrodeposition of High-Functional Metal Oxide on Noble Metal for MEMS Devices

    Get PDF
    MEMS gas sensors could exert a significant impact on the automotive sector since future legislation is expected to stipulate the monitoring of NOx and unburned fuel gases in vehicle exhausts. Among the materials, zinc oxide and TiO2 are the most promising and extensively used materials for monitoring of NOx gas since zinc oxide and TiO2 show the high sensitivity, good stability, and fast response. Electrochemistry is a potential method to fabricate zinc oxide and TiO2 for the applications since it is carried out at relatively low temperature and can cooperate with photolithography, which is an important process in MEMS. This study integrated zinc oxide/gold-layered structure and TiO2/NiP hybrid structure on elastic fabrics, respectively, to realize an elastic gas sensor. Electroless plating (EP) and cathodic deposition were used to metallize and deposit metal oxides on elastic fabrics. Supercritical carbon dioxide (scCO2) was further introduced into the electrochemical process to enhance the composite reliability

    Factors for poor prognosis of neonatal bacterial meningitis in a medical center in Northern Taiwan

    Get PDF
    BackgroundBacterial meningitis has long been a severe infectious disease in neonates, as well as a leading cause of adverse outcomes. We designed this study to know the factors for poor prognosis in neonatal bacterial meningitis.MethodsWe enrolled children aged less than 1 month who were admitted to Mackay Memorial Hospital from 1984 to 2008 and had culture-proven bacterial meningitis. The laboratory data and children’s clinical features were recorded. The patients’ outcomes were divided into four groups: death, having sequelae, complete recovery, and loss to follow-up. Patients with the outcomes of death and having sequelae were regarded as having a poor prognosis. Those who were lost to follow-up were excluded from the analysis of outcome. Multivariate analyses were performed to find the risk factors for poor prognosis.ResultsOne hundred fifty-six neonates fulfilled the inclusion criteria. Among these, 96 were boys (61.5%) and 102 (65.4%) had concomitant bacteremia. Group B streptococci (39.1%) and Escherichia coli (20.1%) were the two leading pathogens. Excluding those who were lost to follow-up (4.5%), 22 of 149 patients (14.8%) died, 36 (24.2%) had sequelae, and 91 (61.1%) recovered completely. Cerebrospinal fluid (CSF) protein more than 500 mg/dL at admission {odds ratio (OR): 171.18 [95% confidence interval (CI): 25.6–1000]}, predisposition to congenital heart disease [OR: 48.96 (95% CI: 6.06–395.64)], hearing impairment found during hospitalization [OR: 23.40 (95% CI: 3.62–151.25)], and seizure at admission or during hospitalization [OR: 10.10 (95% CI: 2.11–48.32)] were the factors predicting poor prognosis.ConclusionIn this 25-year study of newborns with bacterial meningitis, approximately one-seventh of the patients died, while two-fifths had sequelae. Nearly two-thirds of these had concomitant bacteremia. Group B streptococci and E. coli remained the two leading pathogens throughout the study period. Several factors for poor prognosis in newborns with culture-proven bacterial meningitis were found: high CSF protein concentration, congenital heart disease, hearing impairment, and seizure

    Managing cardiac arrest with refractory ventricular fibrillation in the emergency department: Conventional cardiopulmonary resuscitation versus extracorporeal cardiopulmonary resuscitation

    Get PDF
    AbstractAimRefractory ventricular fibrillation, resistant to conventional cardiopulmonary resuscitation (CPR), is a life threatening rhythm encountered in the emergency department. Although previous reports suggest the use of extracorporeal CPR can improve the clinical outcomes in patients with prolonged cardiac arrest, the effectiveness of this novel strategy for refractory ventricular fibrillation is not known. We aimed to compare the clinical outcomes of patients with refractory ventricular fibrillation managed with conventional CPR or extracorporeal CPR in our institution.MethodThis is a retrospective chart review study from an emergency department in a tertiary referral medical center. We identified 209 patients presenting with cardiac arrest due to ventricular fibrillation between September 2011 and September 2013. Of these, 60 patients were enrolled with ventricular fibrillation refractory to resuscitation for more than 10min. The clinical outcome of patients with ventricular fibrillation received either conventional CPR, including defibrillation, chest compression, and resuscitative medication (C-CPR, n=40) or CPR plus extracorporeal CPR (E-CPR, n=20) were compared.ResultsThe overall survival rate was 35%, and 18.3% of patients were discharged with good neurological function. The mean duration of CPR was longer in the E-CPR group than in the C-CPR group (69.90±49.6min vs 34.3±17.7min, p=0.0001). Patients receiving E-CPR had significantly higher rates of sustained return of spontaneous circulation (95.0% vs 47.5%, p=0.0009), and good neurological function at discharge (40.0% vs 7.5%, p=0.0067). The survival rate in the E-CPR group was higher (50% vs 27.5%, p=0.1512) at discharge and (50% vs 20%, p=0. 0998) at 1 year after discharge.ConclusionsThe management of refractory ventricular fibrillation in the emergency department remains challenging, as evidenced by an overall survival rate of 35% in this study. Patients with refractory ventricular fibrillation receiving E-CPR had a trend toward higher survival rates and significantly improved neurological outcomes than those receiving C-CPR

    Prophylactic Cavotricuspid Isthmus Ablation in Atrial Fibrillation without Documented Typical Atrial Flutter: A Systematic Review and Meta-analysis

    Get PDF
    Background: The advantage of prophylactic cavotricuspid isthmus (CTI) ablation for AF patients without documented atrial flutter is still unclear. The present study aimed to evaluate the role of prophylactic CTI ablation in this population. Methods: A systematic review and meta-analysis study was conducted. The overall effects estimation was conducted using random effects models. The pooled effects were presented as the risk difference and standardised mean difference for dichotomous and continuous outcomes, respectively. Results: A total of 1,476 patients from four studies were included. The risk of atrial tachyarrhythmias following a successful catheter ablation procedure was greater in the pulmonary vein isolation + CTI ablation group than pulmonary vein isolation alone group (34.8% versus 28.2%; risk difference 0.08; 95% CI [0.00–0.17]; p=0.04). Prophylactic CTI ablation was associated with a higher recurrent AF rate (33.8% versus 27.1%; risk difference 0.07; 95% CI [0.01–0.13]; p=0.02). Additional prophylactic CTI ablation to pulmonary vein isolation significantly increased the radio frequency application time (standardised mean difference 0.52; 95% CI [0.04–1.01]; p=0.03). Conclusion: This study suggested that prophylactic CTI ablation was an ineffective and inefficient approach in AF without documented typical atrial flutter patients
    • …
    corecore