    Radiation doses in complex diagnostic procedures

    No full text
    EThOS - Electronic Theses Online ServiceGBUnited Kingdo

    Dose optimization for assessment of periodontal structures in cone beam CT examinations

    No full text
    OBJECTIVES: To investigate the relationship between dose and image quality for a dedicated dental CBCT scanner using different scanning protocols and to set up an optimal imaging protocol for assessment of periodontal structures. METHODS: Radiation dose and image quality measurements were made using 3D Accuitomo 170 (J. Morita, Kyoto, Japan) dental CBCT scanner. The SedentexCT IQ phantom was used to investigate the relationship between contrast-to-noise ratio (CNR) and dose-area product. Subjective image quality assessment was achieved using a small adult skull phantom for the same range of exposure settings. Five independent observers assessed the images for three anatomical landmarks using a three-point visual grade analysis. RESULTS: When correlating the CNR of each scanning protocol to the exposure parameters used to obtain it, CNR decreased as these parameters decreased, especially current-exposure time product. When correlating to subjective image quality, the CNR level remained acceptable when 5 mA and 17.5 s or greater was selected and 80 kV could be used without compromising the CNR. CONCLUSIONS: For a dedicated CBCT unit, changing the rotation angle from 360 degrees to 180 degrees degrades image quality. By altering tube potential and current for the 360 degrees rotation protocol, assessment of periodontal structures can be performed with a smaller dose without substantially affecting visualization

    Development of a low-dose protocol for cone beam CT examinations of the anterior maxilla in children.

    No full text
    OBJECTIVE: The aim of this study was to develop a low-dose protocol suitable for cone beam CT (CBCT) examination of an impacted maxillary canine in children by using a combination of dosimetry with subjective and objective image quality assessment. METHODS: Radiation dose and image quality measurements were made using a dental CBCT machine. An image quality phantom was used to investigate the relationship between objective image quality and dose–area product (DAP) for a broad range of exposure settings. Subjective image quality assessment was achieved using a paediatric skull phantom submerged in a water bath for the same range of exposure settings. Eight clinicians assessed each CBCT data set for nine aspects of image quality using a five-point rating scale of agreement. RESULTS: Acceptable image quality, defined using subjective judgements by the clinicians of the skull phantom images, was achievable with DAP values of 127 mGy cm(2) or greater and a polytetrafluoroethylene (PTFE) contrast-to-noise ratio (CNR) of 4.8 or greater. A cautious choice was made to recommend a low-dose protocol of 80 kV and 3 mA for implementation into clinical practice, corresponding to a DAP value of 146 mGy cm(2) and a PTFE CNR of 5.0. CONCLUSION: A low-dose protocol for this particular CBCT machine was established which represents as much as a 50% reduction compared with manufacturer's recommendations. ADVANCES IN KNOWLEDGE: To the authors' best knowledge, this is the first study that addresses dose optimization in paediatric clinical protocols in dental CBCT. Furthermore, this study explores the relationship between radiation dose, objective and subjective image quality

    Use of out-of-field contact shielding on patients in medical imaging: A review of current guidelines, recommendations and legislative documents

    No full text
    The use of patient contact-shielding has become a topic of intensive scientific debate. While it has been common practice during the last decades, some studies have questioned the efficiency of using such shielding while others have highlighted the inconsistencies in its application. The objective of this work is to review current recommendations and legislative documents on the use of out-of-field shielding in X-ray imaging, including those from national authorities and from international and national organisations and professional bodies. The review, performed within the framework of the activities of EURADOS Working Group 12, covers available recommendations on use of contact shielding in adult, pregnant and paediatric patients in general radiography, fluoroscopy, computed tomography, mammography and dental radiology. It includes a comprehensive search of 83 documents from 32 countries and 6 international organisations over the last 39 years. In general, using shielding is recommended only under two conditions: if it does not compromise the diagnostic task and the performance of the procedure and/or if it reassures the patient and comforters that they are appropriately protected against potentially harmful effects of radiation. There are very few specific regulatory requirements to use shielding in a particular imaging modality, although they may consider use of shielding either as part of good radiological practice or as requirements for availability of protective or ancillary tools, without further specification of their use. There is a wide variety of positions among documents that recommend out-offield shielding, those that do not recommend it and those that are not specific. Therefore, evidence-based consensus is still needed to ensure best and consistent practice