4 research outputs found
Assessing full thickness oral mucosal grafting: complications and postoperative outcomes in a broad collective of patients
Background:
Conjunctival defects can be repaired with several mucosal tissues. The simplicity of harvesting oral mucosa and its wide availability makes it the preferred graft tissue for all indications requiring mucosal grafting. Through analysing the postsurgical outcomes and rate of revisions, this study explores the suitability of oral mucosa grafts, depending on the initial diagnosis.
Methods:
We reviewed all the files of patients with a history of oral mucosal graft surgery, performed at our clinic between 2012 and 2018, focusing on complications and revision rates.
Results:
In total, we analysed 173 oral mucosa grafts in 131 patients. The most common initial diagnosis was tumour resection, followed by surgical complications, postenucleation socket syndrome, trauma and ocular surface disorders. Complication and revision rates depended highly on the initial diagnosis. Revision rates were highest if the initial diagnosis included ocular surface disorders or chemical trauma.
Conclusions:
Oral mucosa grafting (OMG) is the most effective treatment for a wide range of ocular conditions involving conjunctival defects. Conjunctival defects that result from trauma or cicatricial surface diseases seem less suitable for OMG and may benefit from alternative graft tissue or treatment options
Exploring the precision of femtosecond laser-assisted descemetorhexis in Descemet membrane endothelial keratoplasty
Objective Descemet membrane endothelial keratoplasty (DMEK) remains a challenging technique. We compare the precision of femtosecond laser-assisted DMEK to manual DMEK. Methods and Analysis A manual descemetorhexis (DR) of 8 mm diameter was compared with a femtosecond laser-assisted DR of the same diameter (femto-DR) in 22 pseudophakic patients requiring DMEK. We used OCT images with a centred xy-diagram to measure the postoperative precision of the DR and the amount of endothelial denuded area. Endothelial cell loss (ECL) and best corrected visual acuity were measured 3 months after surgery. Results In the manual group, the median error of the DR was 7% (range 3%-16%) in the x-diameter and 8% (range 2%-17%) in the y-diameter. In the femto group, the median error in the respective x and y-diameters was 1% (range 0.4%-3%) and 1% (range 0.006%-2.5%), smaller than in the manual group (p=0.001). Endothelial denuded areas were larger in the manual group (11.6 mm(2), range 7.6-18 mm(2)) than in the femto group (2.5 mm(2), range 1.25.9 mm(2)) (p<0.001). The ECL was 21% (range 5%-78%) in the manual DR and 17% (range 6%-38%) in the femto-DR group (p=0.351). The median visual acuity increased from 0.4 logMAR (range 0.6-0.4 logMAR) in both groups to 0.1 logMAR (range 0.4-0 logMAR) in the manual group and to 0.1 logMAR (range 0.3-0 logMAR) in the femto group (p=0.461). Three rebubblings were required in the manual group, whereas the femto group required only one. Conclusion The higher precision of the femto-DR bears the potential to improve DMEK surgery