105 research outputs found

    Effect of coronary flow on intracoronary alteplase: a prespecified analysis from a randomised trial

    Get PDF
    Objectives: Persistently impaired culprit artery flow (<TIMI 3) during primary percutaneous coronary intervention is a surrogate for failed myocardial perfusion. We evaluated the effects of intracoronary alteplase according to TIMI flow grade immediately preceding drug administration. Methods: In T-TIME (trial of low-dose adjunctive alTeplase during primary PCI), patients ≤6 hours from onset of ST-elevation myocardial infarction (STEMI) were randomised to placebo, alteplase 10 mg or alteplase 20 mg, administered by infusion into the culprit artery, pre-stenting. In this prespecified, secondary analysis, coronary flow was assessed angiographically at the point immediately before drug administration. Microvascular obstruction, myocardial haemorrhage and infarct size were assessed by cardiovascular magnetic resonance (CMR) at 2–7 days and 3 months. Results: TIMI flow was assessed after first treatment (balloon angioplasty/aspiration thrombectomy), immediately pre-drug administration, in 421 participants (mean age 61±10 years, 85% male) and was 3, 2 or 1 in 267, 134 and 19 participants respectively. In patients with TIMI flow ≤2 pre-drug, there was higher incidence of microvascular obstruction with alteplase (alteplase 20 mg (53.1%) and 10 mg (59.5%) combined versus placebo (34.1%); OR=2.47 (95% CI 1.16 to 5.22, p=0.018) interaction p=0.005) and higher incidence of myocardial haemorrhage (alteplase 20 mg (53.1%) and 10 mg (57.9%) combined vs placebo (27.5%); OR=3.26 (95% CI 1.44 to 7.36, p=0.004) interaction p=0.001). These effects were not observed in participants with TIMI 3 flow pre-drug. There were no interactions between TIMI flow pre-drug, alteplase and 3-month CMR findings. Conclusion: In patients with impaired culprit artery flow (<TIMI 3) after initial balloon angioplasty/thrombus aspiration, intracoronary alteplase was associated with increased presence of microvascular obstruction and myocardial haemorrhage

    Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies

    Get PDF
    Objectives: The purpose of this document is to make the output of the International Working Group for Intravascular Optical Coherence Tomography (IWG-IVOCT) Standardization and Validation available to medical and scientific communities, through a peer-reviewed publication, in the interest of improving the diagnosis and treatment of patients with atherosclerosis, including coronary artery disease. Background: Intravascular optical coherence tomography (IVOCT) is a catheter-based modality that acquires images at a resolution of ∼10 μm, enabling visualization of blood vessel wall microstructure in vivo at an unprecedented level of detail. IVOCT devices are now commercially available worldwide, there is an active user base, and the interest in using this technology is growing. Incorporation of IVOCT in research and daily clinical practice can be facilitated by the development of uniform terminology and consensus-based standards on use of the technology, interpretation of the images, and reporting of IVOCT results. Methods: The IWG-IVOCT, comprising more than 260 academic and industry members from Asia, Europe, and the United States, formed in 2008 and convened on the topic of IVOCT standardization through a series of 9 national and international meetings. Results: Knowledge and recommendations from this group on key areas within the IVOCT field were assembled to generate this consensus document, authored by the Writing Committee, composed of academicians who have participated in meetings and/or writing of the text. Conclusions: This document may be broadly used as a standard reference regarding the current state of the IVOCT imaging modality, intended for researchers and clinicians who use IVOCT and analyze IVOCT data
    • …
    corecore