2,312 research outputs found

    Kosp2e: Korean Speech to English Translation Corpus

    Full text link
    Most speech-to-text (S2T) translation studies use English speech as a source, which makes it difficult for non-English speakers to take advantage of the S2T technologies. For some languages, this problem was tackled through corpus construction, but the farther linguistically from English or the more under-resourced, this deficiency and underrepresentedness becomes more significant. In this paper, we introduce kosp2e (read as `kospi'), a corpus that allows Korean speech to be translated into English text in an end-to-end manner. We adopt open license speech recognition corpus, translation corpus, and spoken language corpora to make our dataset freely available to the public, and check the performance through the pipeline and training-based approaches. Using pipeline and various end-to-end schemes, we obtain the highest BLEU of 21.3 and 18.0 for each based on the English hypothesis, validating the feasibility of our data. We plan to supplement annotations for other target languages through community contributions in the future.Comment: Interspeech 2021 Camera-read

    Geometric nonlinear diffusion filter and its application to X-ray imaging

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Denoising with edge preservation is very important in digital x-ray imaging since it may allow us to reduce x-ray dose in human subjects without noticeable degradation of the image quality. In denoising filter design for x-ray imaging, edge preservation as well as noise reduction is of great concern not to lose detailed spatial information for accurate diagnosis. In addition to this, fast computation is also important since digital x-ray images are mostly comprised of large sized matrices.</p> <p>Methods</p> <p>We have developed a new denoising filter based on the nonlinear diffusion filter model. Rather than employing four directional gradients around the pixel of interest, we use geometric parameters derived from the local pixel intensity distribution in calculating the diffusion coefficients in the horizontal and vertical directions. We have tested the filter performance, including edge preservation and noise reduction, using low dose digital radiography and micro-CT images.</p> <p>Results</p> <p>The proposed denoising filter shows performance similar to those of nonlinear anisotropic diffusion filters (ADFs), one Perona-Malik ADF and the other Weickert's ADF in terms of edge preservation and noise reduction. However, the computation time has been greatly reduced.</p> <p>Conclusions</p> <p>We expect the proposed denoising filter can be greatly used for fast noise reduction particularly in low-dose x-ray imaging.</p

    Investigating an Effective Character-level Embedding in Korean Sentence Classification

    Get PDF
    conference pape

    Inter-plane artifact suppression in tomosynthesis using 3D CT image data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Despite its superb lateral resolution, flat-panel-detector (FPD) based tomosynthesis suffers from low contrast and inter-plane artifacts caused by incomplete cancellation of the projection components stemming from outside the focal plane. The incomplete cancellation of the projection components, mostly due to the limited scan angle in the conventional tomosynthesis scan geometry, often makes the image contrast too low to differentiate the malignant tissues from the background tissues with confidence.</p> <p>Methods</p> <p>In this paper, we propose a new method to suppress the inter-plane artifacts in FPD-based tomosynthesis. If 3D whole volume CT images are available before the tomosynthesis scan, the CT image data can be incorporated into the tomosynthesis image reconstruction to suppress the inter-plane artifacts, hence, improving the image contrast. In the proposed technique, the projection components stemming from outside the region-of-interest (ROI) are subtracted from the measured tomosynthesis projection data to suppress the inter-plane artifacts. The projection components stemming from outside the ROI are calculated from the 3D whole volume CT images which usually have lower lateral resolution than the tomosynthesis images. The tomosynthesis images are reconstructed from the subtracted projection data which account for the x-ray attenuation through the ROI. After verifying the proposed method by simulation, we have performed both CT scan and tomosynthesis scan on a phantom and a sacrificed rat using a FPD-based micro-CT.</p> <p>Results</p> <p>We have measured contrast-to-noise ratio (CNR) from the tomosynthesis images which is an indicator of the residual inter-plane artifacts on the focal-plane image. In both cases of the simulation and experimental imaging studies of the contrast evaluating phantom, CNRs have been significantly improved by the proposed method. In the rat imaging also, we have observed better visual contrast from the tomosynthesis images reconstructed by the proposed method.</p> <p>Conclusions</p> <p>The proposed tomosynthesis technique can improve image contrast with aids of 3D whole volume CT images. Even though local tomosynthesis needs extra 3D CT scanning, it may find clinical applications in special situations in which extra 3D CT scan is already available or allowed.</p

    Fluid-filled Giant Bulla Treated with Percutaneous Drainage and Talc Sclerotherapy: A Modified Brompton Technique

    Get PDF
    A 75-year-old man who was diagnosed as having a fluid-filled giant bulla was treated with a modified Brompton technique due to his poor performance status. Percutaneous drainage, suction, and talc sclerotherapy through a Foley catheter can be good treatment options for patients with conditions that are too poor to allow surgical intervention, especially if there is adhesion between a giant bulla and parietal pleura. Talc can also be used safely when mixed with normal saline as a sclerosant

    Elevated matrix metalloproteinase-9 in patients with systemic sclerosis

    Get PDF
    Matrix metalloproteinase-9 (MMP-9) has been implicated in the pathogenesis of cancer, autoimmune disease, and various pathologic conditions characterized by excessive fibrosis. In this study, we investigated the expression of MMP-9 and its clinical significance in systemic sclerosis (SSc). The patients (n = 42) with SSc had higher concentrations of MMP-9 and of tissue inhibitor of metalloproteinase-1 (TIMP-1) and a higher ratio of MMP-9 to TIMP-1 in sera than healthy controls (n = 32). Serum MMP-9 concentrations were significantly higher in the diffuse type (n = 23) than the limited type of SSc (n = 19). Serum concentrations of MMP-9 correlated well with the degree of skin involvement, as determined by the Rodnan score and with serum concentrations of transforming growth factor β. Moreover, dermal fibroblasts from patients with SSc produced more MMP-9 than those from healthy controls when they were stimulated with IL-1β, tumor necrosis factor α, or transforming growth factor β. Such an increase in MMP-9 production was partially blocked by treatment with cyclosporin A. In summary, the serum MMP-9 concentrations were elevated in SSc patients and correlated well with skin scores. The increased MMP-9 concentrations may be attributable to overproduction by dermal fibroblasts in SSc. These findings suggest that the enhanced production of MMP-9 may contribute to fibrogenic remodeling during the progression of skin sclerosis in SSc

    Carotid Intimal-Medial Thickness Is Not Increased in Women with Previous Gestational Diabetes Mellitus

    Get PDF
    BackgroundGestational diabetes mellitus (GDM) is known to increase the risk of cardiovascular diseases. Measuring the carotid artery intimal-medial thickness (CIMT) is a non-invasive technique used to evaluate early atherosclerosis and to predict future cardiovascular diseases. We examined the association between CIMT and cardiovascular risk factors in young Korean women with previous GDM.MethodsOne hundred one women with previous GDM and 19 women who had normal pregnancies (NP) were recruited between 1999 and 2002. At one year postpartum, CIMT was measured using high-resolution B-mode ultrasonography, and oral glucose tolerance tests were performed. Fasting glucose, glycated hemoglobin A1c (HbA1c), insulin levels and lipid profiles were also measured. CIMTs in the GDM and NP groups were compared, and the associations between CIMT and cardiovascular risk factors were analyzed in the GDM group.ResultsCIMT results of the GDM group were not significantly different from those of the NP group (GDM, 0.435±0.054 mm; NP, 0.460±0.046 mm; P=0.069). In the GDM group, a higher HbA1c was associated with an increase in CIMT after age adjustment (P=0.011). CIMT results in the group with HbA1c >6.0% were higher than those of the normal HbA1c (HbA1c ≤6.0%) (P=0.010). Nine of the patients who are type 2 diabetes mellitus converters within one year postpartum but showed no significant difference in CIMT results compared to NP group.ConclusionHigher HbA1c is associated with an increase in CIMT in women with previous GDM. However, CIMT at one year postpartum was not increased in these women compared to that in NP women
    corecore