3,657 research outputs found

    Evolution and dimensional crossover from the bulk subbands in ABC-stacked graphene to a three-dimensional Dirac cone structure in rhombohedral graphite

    Full text link
    The band structure of ABC-stacked N-layer graphene comprises topologically corresponding flat surface and gapped bulk subbands, as a consequence of the unique stacking configuration. In this paper, the bulk subbands are for the first times ever obtained for arbitrary N. A non-perturbative effective Hamiltonian closed in the bulk subspace is derived and used. The gapped bulk subbands are shown to evolve towards the zero energy with increasing N and in the infinite limit, they touch linearly along a circle. This outcome is a manifestation of the dimensional crossover to a three-dimensional Dirac cone structure known to exist in the bulk of rhombohedral graphite. The Dirac points, forming continuous nodal lines in a spiraling fashion, are projected onto the circle, within which the surface subbands are confined and flatten.Comment: 23 pages, 4 figure

    Poecilostomatoid Copepods Parasitic in Bivalve Mollusks of Taiwan

    Get PDF
    Three species of poecilostomatoid copepods parasitic in bivalve mollusks of Taiwan were described. They are: Ostrincola simi/is sp. nov. from the cultured oyster, Crassostrea gigas (Thunberg), and green mussel, Perna viridis (Linnaeus), attached to this species of oyster; Myicola formosanus sp. nov. from the circular clam, Cyclina sinensis (Gmelin); and Anthessius mytilicolus Reddiah, 1966 from the green mussels attached to the cultured C. gigas. This is the first report of parasitic copepods from the bivalve mollusks of Taiwan

    The Taiwan ECDFS Near-Infrared Survey: Ultra-deep J and Ks Imaging in the Extended Chandra Deep Field-South

    Get PDF
    We present ultra-deep J and Ks imaging observations covering a 30' * 30' area of the Extended Chandra Deep Field-South (ECDFS) carried out by our Taiwan ECDFS Near-Infrared Survey (TENIS). The median 5-sigma limiting magnitudes for all detected objects in the ECDFS reach 24.5 and 23.9 mag (AB) for J and Ks, respectively. In the inner 400 arcmin^2 region where the sensitivity is more uniform, objects as faint as 25.6 and 25.0 mag are detected at 5-sigma. So this is by far the deepest J and Ks datasets available for the ECDFS. To combine the TENIS with the Spitzer IRAC data for obtaining better spectral energy distributions of high-redshift objects, we developed a novel deconvolution technique (IRACLEAN) to accurately estimate the IRAC fluxes. IRACLEAN can minimize the effect of blending in the IRAC images caused by the large point-spread functions and reduce the confusion noise. We applied IRACLEAN to the images from the Spitzer IRAC/MUSYC Public Legacy in the ECDFS survey (SIMPLE) and generated a J+Ks selected multi-wavelength catalog including the photometry of both the TENIS near-infrared and the SIMPLE IRAC data. We publicly release the data products derived from this work, including the J and Ks images and the J+Ks selected multiwavelength catalog.Comment: 25 pages, 25 figures, ApJS in pres

    Improving interface bonding of double-skinned CFST columns

    Get PDF
    It has been demonstrated that high-strength concrete (HSC) is able to improve the strength-to-weight ratio of reinforced concrete columns and maximise the usable areas of tall buildings. However, closely spaced transverse reinforcement needs to be installed to provide stronger confinement for averting brittle failure of HSC. To resolve the problem, double-skinned concrete-filled-steel-tubular (CFST) columns have been advocated, which eliminates the steel congestion problem for better concrete placing and reduces the concrete arching action thus providing a more uniform confining pressure. Despite these advantages, a major shortcoming of double-skinned CFST columns is that imperfect interface bonding occurs in the elastic stage that reduces elastic strength and stiffness. Thus, the authors proposed to adopt external confinement to restrict the lateral dilation of the outer tube of double-skinned CFST columns. To verify the effectiveness of the proposed external rings, a total of 20 double-skinned normal- and high-strength CFST columns were tested. From the test results, it was observed that the stiffness, axial load-carrying capacity and ductility of ringconfined double-skinned CFST columns were significantly higher than the unconfined columns

    Hyperspectral sensing for turbid water quality monitoring in freshwater rivers: Empirical relationship between reflectance and turbidity and total solids

    Get PDF
    Total suspended solid (TSS) is an important water quality parameter. This study was conducted to test the feasibility of the band combination of hyperspectral sensing for inland turbid water monitoring in Taiwan. The field spectral reflectance in the Wu river basin of Taiwan was measured with a spectroradiometer; the water samples were collected from the different sites of the Wu river basin and some water quality parameters were analyzed on the sites (in situ) as well as brought to the laboratory for further analysis. To obtain the data set for this study, 160 in situ sample observations were carried out during campaigns from August to December, 2005. The water quality results were correlated with the reflectivity to determine the spectral characteristics and their relationship with turbidity and TSS. Furthermore, multiple-regression (MR) and artificial neural network (ANN) were used to model the transformation function between TSS concentration and turbidity levels of stream water, and the radiance measured by the spectroradiometer. The value of the turbidity and TSS correlation coefficient was 0.766, which implies that turbidity is significantly related to TSS in the Wu river basin. The results indicated that TSS and turbidity are positively correlated in a significant way across the entire spectrum, when TSS concentration and turbidity levels were under 800 mg·L(-1) and 600 NTU, respectively. Optimal wavelengths for the measurements of TSS and turbidity are found in the 700 and 900 nm range, respectively. Based on the results, better accuracy was obtained only when the ranges of turbidity and TSS concentration were less than 800 mg·L(-1) and less than 600 NTU, respectively and used rather than using whole dataset (R(2) = 0.93 versus 0.88 for turbidity and R(2) = 0.83 versus 0.58 for TSS). On the other hand, the ANN approach can improve the TSS retrieval using MR. The accuracy of TSS estimation applying ANN (R(2) = 0.66) was better than with the MR approach (R(2) = 0.58), as expected due to the nonlinear nature of the transformation model
    corecore