318 research outputs found
Recommended from our members
Arthritis imaging using a near-infrared fluorescence folate-targeted probe
A recently developed near-infrared fluorescence-labeled folate probe (NIR2-folate) was tested for in vivo imaging of arthritis using a lipopolysaccharide intra-articular injection model and a KRN transgenic mice serum induction mouse model. In the lipopolysaccharide injection model, the fluorescence signal intensity of NIR2-folate (n = 12) and of free NIR2 (n = 5) was compared between lipopolysaccharide-treated and control joints. The fluorescence signal intensity of the NIR2-folate probe at the inflammatory joints was found to be significantly higher than the control normal joints (up to 2.3-fold, P < 0.001). The NIR2-free dye injection group showed a persistent lower enhancement ratio than the NIR2-folate probe injection group. Excessive folic acid was also given to demonstrate a competitive effect with the NIR2-folate. In the KRN serum transfer model (n = 4), NIR2-folate was applied at different time points after serum transfer, and the inflamed joints could be detected as early as 30 hours after arthritogenic antibody transfer (1.8-fold increase in signal intensity). Fluorescence microscopy, histology, and immunohistochemistry validated the optical imaging results. We conclude that in vivo arthritis detection was feasible using a folate-targeted near-infrared fluorescence probe. This receptor-targeted imaging method may facilitate improved arthritis diagnosis and early assessment of the disease progress by providing an in vivo characterization of active macrophage status in inflammatory joint diseases
Recommended from our members
An authentic imaging probe to track cell fate from beginning to end
Accurate tracing of cell viability is critical for optimizing delivery methods, and evaluating the efficacy and safety of cell therapeutics. A nanoparticle-based cell tracker is developed to image cell fate from live to dead. The particle is fabricated from two types of optically quenched polyelectrolytes, a life indicator and a death indicator, through electrostatic interactions. Upon incubation with cells, the fabricated bifunctional nanoprobes are taken up efficiently, and the first color is produced by normal intracellular proteolysis, reflecting the healthy status of the cells. Depending on the number of coated layers, the signal can persist for several replication cycles. However, as the cells begin dying, the second color appears quickly to reflect the new cell status. Using this chameleon-like cell tracker, live cells can be distinguished from apoptotic and necrotic cells instantly and definitively
Detection of pancreatic cancer tumours and precursor lesions by cathepsin E activity in mouse models.
ABSTRACT Background and Aims Pancreatic ductal adenocarcinoma (PDAC) is the fourth leading cause of cancer death in the USA. Surgical resection is the only effective treatment; however, only 20% of patients are candidates for surgery. The ability to detect early PDAC would increase the availability of surgery and improve patient survival. This study assessed the feasibility of using the enzymatic activity of cathepsin E (Cath E), a protease highly and specifically expressed in PDAC, as a novel biomarker for the detection of pancreas-bearing pancreatic intraepithelial neoplasia (PanIN) lesions and PDAC. Methods Pancreas from normal, chronic pancreatitis and PDAC patients was assessed for Cath E expression by quantitative real-time PCR and immunohistochemistry. Human PDAC xenografts and genetically engineered mouse models (GEMM) of PDAC were injected with a Cath E activity selective fluorescent probe and imaged using an optical imaging system. Results The specificity of Cath E expression in PDAC patients and GEMM of pancreatic cancer was confirmed by quantitative real-time PCR and immunohistochemistry. The novel probe for Cath E activity specifically detected PDAC in both human xenografts and GEMM in vivo. The Cath E sensitive probe was also able to detect pancreas with PanIN lesions in GEMM before tumour formation. Conclusions The elevated Cath E expression in PanIN and pancreatic tumours allowed in-vivo detection of human PDAC xenografts and imaging of pancreas with PanIN and PDAC tumours in GEMM. Our results support the usefulness of Cath E activity as a potential molecular target for PDAC and early detection imaging. Despite great efforts to help patients with pancreatic ductal adenocarcinoma (PDAC) in the past few years, this disease remains devastating with the worst outcome of all major cancers. In the USA, PDAC ranks 10th in terms of incidence, but for both men and women, it is fourth in terms of cancer deaths. Although many molecular biomarker candidates of PDAC have been identified, 3 biomarkers with the necessary sensitivity and specificity for early detection are still lacking. 4e6 The most widely utilised blood-based biomarker is CA 19-9, which is not expressed in all patients, is not highly specific as it is elevated in other gastrointestinal cancers, and is not useful for the detection of early disease. 7 8 Furthermore, CA 19-9 levels do not provide information about the localisation of the disease nor the existence of metastases. The most sensitive diagnosis of PDAC currently requires invasive imaging procedures such as endoscopic ultrasonography, which Significance of this study What is already known about this subject? < No highly specific and sensitive biomarkers are clinically available for the detection of PDAC at an early stage. < Cath E is highly overexpressed in many cancers including PDAC. < A Cath E selective peptide was recently identified that specifically detects its enzymatic activity. What are the new findings? < We demonstrate that the elevated levels of Cath E expression in early pancreatic cancer lesions and pancreatic tumours could be exploited for PDAC detection. < We illustrate that the detection and localisation of PDAC in mouse xenografts and GEMM was possible utilising the outstanding specificity of a novel Cath E-activatable imaging probe. How might it impact on clinical practice in the foreseeable future? < The ability to detect and visualise pancreatic tumours and PanIN in PDAC by virtue of Cath E activity sensitive probes in preclinical mouse models suggests that modifications of this approach will be useful for the early detection and management of this deadly cancer in patients. < The specificity of Cath E activity for PDAC suggests that this enzymatic activity will be useful in the future for the development of novel therapeutics or theranostics. Cruz-Monserrate Z, Abd-Elgaliel WR, Grote T, et al. Gut (2011)
Assessment of Cardiovascular Fibrosis Using Novel Fluorescent Probes
Cardiovascular fibrosis resulted from pressure overload or ischemia could alter myocardial stiffness and lead to ventricular dysfunction. Fluorescently labeled collagen-binding protein CNA 35, derived from the surface component of Staphylococcus aureus, and a novel synthetic biphenylalanine containing peptide are applied to stain fibrosis associated collagen and myocytes, respectively. Detailed pathological characteristics of cardiovascular fibrosis could be identified clearly in 2 hours. This staining pair requires only simple staining and brief washing, generating less than 10 ml of waste. The image information collected by this novel fluorescent staining pair is compatible with it collected by the traditional Masson's Trichrome and Picrosirius Red staining which are widely used to stain cardiovascular fibrosis and isolated cells
Distinct DNA methylation epigenotypes in bladder cancer from different Chinese sub-populations and its implication in cancer detection using voided urine
<p>Abstract</p> <p>Background</p> <p>Bladder cancer is the sixth most common cancer in the world and the incidence is particularly high in southwestern Taiwan. Previous studies have identified several tumor-related genes that are hypermethylated in bladder cancer; however the DNA methylation profile of bladder cancer in Taiwan is not fully understood.</p> <p>Methods</p> <p>In this study, we compared the DNA methylation profile of multiple tumor suppressor genes (<it>APC</it>, <it>DAPK</it>, <it>E-cadherin</it>, <it>hMLH1</it>, <it>IRF8</it>, <it>p14</it>, <it>p15</it>, <it>RASSF1A</it>, <it>SFRP1 </it>and <it>SOCS-1</it>) in bladder cancer patients from different Chinese sub-populations including Taiwan (104 cases), Hong Kong (82 cases) and China (24 cases) by MSP. Two normal human urothelium were also included as control. To investigate the diagnostic potential of using DNA methylation in non-invasive detection of bladder cancer, degree of methylation of <it>DAPK</it>, <it>IRF8</it>, <it>p14</it>, <it>RASSF1A </it>and <it>SFRP1 </it>was also accessed by quantitative MSP in urine samples from thirty bladder cancer patients and nineteen non-cancer controls.</p> <p>Results</p> <p>There were distinct DNA methylation epigenotypes among the different sub-populations. Further, samples from Taiwan and China demonstrated a bimodal distribution suggesting that CpG island methylator phentotype (CIMP) is presented in bladder cancer. Moreover, the number of methylated genes in samples from Taiwan and Hong Kong were significantly correlated with histological grade (P < 0.01) and pathological stage (P < 0.01). Regarding the samples from Taiwan, methylation of <it>SFRP1</it>, <it>IRF8</it>, <it>APC </it>and <it>RASSF1A </it>were significantly associated with increased tumor grade, stage. Methylation of <it>RASSF1A </it>was associated with tumor recurrence. Patients with methylation of <it>APC </it>or <it>RASSF1A </it>were also significantly associated with shorter recurrence-free survival. For methylation detection in voided urine samples of cancer patients, the sensitivity and specificity of using any of the methylated genes (<it>IRF8</it>, <it>p14 </it>or <it>sFRP1</it>) by qMSP was 86.7% and 94.7%.</p> <p>Conclusions</p> <p>Our results indicate that there are distinct methylation epigenotypes among different Chinese sub-populations. These profiles demonstrate gradual increases with cancer progression. Finally, detection of gene methylation in voided urine with these distinct DNA methylation markers is more sensitive than urine cytology.</p
Management of ulcerative colitis in Taiwan: consensus guideline of the Taiwan Society of Inflammatory Bowel Disease updated in 2023
Ulcerative colitis (UC) is a chronic inflammation of the gastrointestinal tract and is characterized by alternating periods of inflammation and remission. Although UC incidence is lower in Taiwan than in Western countries, its impact remains considerable, demanding updated guidelines for addressing local healthcare challenges and patient needs. The revised guidelines employ international standards and recent research, emphasizing practical implementation within the Taiwanese healthcare system. Since the inception of the guidelines in 2017, the Taiwan Society of Inflammatory Bowel Disease has acknowledged the need for ongoing revisions to incorporate emerging therapeutic options and evolving disease management practices. This updated guideline aims to align UC management with local contexts, ensuring comprehensive and context-specific recommendations, thereby raising the standard of care for UC patients in Taiwan. By adapting and optimizing international protocols for local relevance, these efforts seek to enhance health outcomes for patients with UC
Management of Crohn’s disease in Taiwan: consensus guideline of the Taiwan Society of Inflammatory Bowel Disease updated in 2023
Crohn’s disease (CD) is a chronic, fluctuating inflammatory condition that primarily affects the gastrointestinal tract. Although the incidence of CD in Taiwan is lower than that in Western countries, the severity of CD presentation appears to be similar between Asia and the West. This observation indicates the urgency for devising revised guidelines tailored to the unique reimbursement system, and patient requirements in Taiwan. The core objectives of these updated guidelines include the updated treatment choices and the integration of the treat-to-target strategy into CD management, promoting the achievement of deep remission to mitigate complications and enhance the overall quality of life. Given the diversity in disease prevalence, severity, insurance policies, and access to medical treatments in Taiwan, a customized approach is imperative for formulating these guidelines. Such tailored strategies ensure that international standards are not only adapted but also optimized to local contexts. Since the inception of its initial guidelines in 2017, the Taiwan Society of Inflammatory Bowel Disease (TSIBD) has acknowledged the importance of continuous revisions for incorporating new therapeutic options and evolving disease management practices. The latest update leverages international standards and recent research findings focused on practical implementation within the Taiwanese healthcare system
Robust estimation of bacterial cell count from optical density
Optical density (OD) is widely used to estimate the density of cells in liquid culture, but cannot be compared between instruments without a standardized calibration protocol and is challenging to relate to actual cell count. We address this with an interlaboratory study comparing three simple, low-cost, and highly accessible OD calibration protocols across 244 laboratories, applied to eight strains of constitutive GFP-expressing E. coli. Based on our results, we recommend calibrating OD to estimated cell count using serial dilution of silica microspheres, which produces highly precise calibration (95.5% of residuals <1.2-fold), is easily assessed for quality control, also assesses instrument effective linear range, and can be combined with fluorescence calibration to obtain units of Molecules of Equivalent Fluorescein (MEFL) per cell, allowing direct comparison and data fusion with flow cytometry measurements: in our study, fluorescence per cell measurements showed only a 1.07-fold mean difference between plate reader and flow cytometry data
- …
