24 research outputs found

    Long-term glycine propionyl-l-carnitine supplemention and paradoxical effects on repeated anaerobic sprint performance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>It has been demonstrated that acute GPLC supplementation produces enhanced anaerobic work capacity with reduced lactate production in resistance trained males. However, it is not known what effects chronic GPLC supplementation has on anaerobic performances or lactate clearance.</p> <p>Purpose</p> <p>The purpose of this study was to examine the long-term effects of different dosages of GPLC supplementation on repeated high intensity stationary cycle sprint performance.</p> <p>Methods</p> <p>Forty-five resistance trained men participated in a double-blind, controlled research study. All subjects completed two testing sessions, seven days apart, 90 minutes following oral ingestion of either 4.5 grams GPLC or 4.5 grams cellulose (PL), in randomized order. The exercise testing protocol consisted of five 10-second Wingate cycle sprints separated by 1-minute active recovery periods. Following completion of the second test session, the 45 subjects were randomly assigned to receive 1.5 g, 3.0 g, or 4.5 g GPLC per day for a 28 day period. Subjects completed a third test session following the four weeks of GPLC supplementation using the same testing protocol. Values of peak power (PP), mean power (MP) and percent decrement of power (DEC) were determined per bout and standardized relative to body mass. Heart rate (HR) and blood lactate (LAC) were measured prior to, during and following the five sprint bouts.</p> <p>Results</p> <p>There were no significant effects of condition or significant interaction effects detected for PP and MP. However, results indicated that sprint bouts three, four and five produced 2 - 5% lower values of PP and 3 - 7% lower values of MP with GPLC at 3.0 or 4.5 g per day as compared to baseline values. Conversely, 1.5 g GPLC produced 3 - 6% higher values of PP and 2 -5% higher values of MP compared with PL baseline values. Values of DEC were significantly greater (15-20%) greater across the five sprint bouts with 3.0 g or 4.5 g GPLC, but the 1.5 g GPLC supplementation produced DEC values -5%, -3%, +4%, +5%, and +2% different from the baseline PL values. The 1.5 g group displayed a statistically significant 24% reduction in net lactate accumulation per unit power output (p < 0.05).</p> <p>Conclusions</p> <p>The effects of GPLC supplementation on anaerobic work capacity and lactate accumulation appear to be dosage dependent. Four weeks of GPLC supplementation at 3.0 and 4.5 g/day resulted in reduced mean values of power output with greater rates of DEC compared with baseline while 1.5 g/day produced higher mean values of MP and PP with modest increases of DEC. Supplementation of 1.5 g/day also produced a significantly lower rate of lactate accumulation per unit power output compared with 3.0 and 4.5 g/day. In conclusion, GPLC appears to be a useful dietary supplement to enhance anaerobic work capacity and potentially sport performance, but apparently the dosage must be determined specific to the intensity and duration of exercise.</p

    Algorithm for identifying and separating beats from arterial pulse records

    Get PDF
    BACKGROUND: This project was designed as an epidemiological aid-selecting tool for a small country health center with the general objective of screening out possible coronary patients. Peripheral artery function can be non-invasively evaluated by impedance plethysmography. Changes in these vessels appear as good predictors of future coronary behavior. Impedance plethysmography detects volume variations after simple occlusive maneuvers that may show indicative modifications in arterial/venous responses. Averaging of a series of pulses is needed and this, in turn, requires proper determination of the beginning and end of each beat. Thus, the objective here is to describe an algorithm to identify and separate out beats from a plethysmographic record. A secondary objective was to compare the output given by human operators against the algorithm. METHODS: The identification algorithm detected the beat's onset and end on the basis of the maximum rising phase, the choice of possible ventricular systolic starting points considering cardiac frequency, and the adjustment of some tolerance values to optimize the behavior. Out of 800 patients in the study, 40 occlusive records (supradiastolic- subsystolic) were randomly selected without any preliminary diagnosis. Radial impedance plethysmographic pulse and standard ECG were recorded digitizing and storing the data. Cardiac frequency was estimated with the Power Density Function and, thereafter, the signal was derived twice, followed by binarization of the first derivative and rectification of the second derivative. The product of the two latter results led to a weighing signal from which the cycles' onsets and ends were established. Weighed and frequency filters are needed along with the pre-establishment of their respective tolerances. Out of the 40 records, 30 seconds strands were randomly chosen to be analyzed by the algorithm and by two operators. Sensitivity and accuracy were calculated by means of the true/false and positive/negative criteria. Synchronization ability was measured through the coefficient of variation and the median value of correlation for each patient. These parameters were assessed by means of Friedman's ANOVA and Kendall Concordance test. RESULTS: Sensitivity was 97% and 91% for the two operators, respectively, while accuracy was cero for both of them. The synchronism variability analysis was significant (p < 0.01) for the two statistics, showing that the algorithm produced the best result. CONCLUSION: The proposed algorithm showed good performance as expressed by its high sensitivity. The correlation analysis demonstrated that, from the synchronism point of view, the algorithm performed the best detection. Patients with marked arrhythmic processes are not good candidates for this kind of analysis. At most, they would be singled out by the algorithm and, thereafter, to be checked by an operator
    corecore