32 research outputs found

    Polyethylene thickness is a risk factor for wear necessitating insert exchange

    Get PDF
    PURPOSE: The aim of this observational study was to investigate the optimal minimal polyethylene (PE) thickness in total knee arthroplasty (TKA) and identify other risk factors associated with revision of the insert due to wear. METHODS: A total of 84 TKA were followed for 11-16 years. All patients received the same prosthesis design (Interax; Howmedica/ Stryker) with halfbearings: separate PE-inserts medially and laterally. Statistical analysis comprised Cox-regression to correct for confounding. RESULTS: Eight knees (9.5%) had been revised due to thinning inserts and an additional patient is scheduled for revision. PE thickness, diagnosis, BMI and weight are risk factors for insert exchange. For each millimetre decrease in PE thickness, the risk of insert exchange increases 3.0 times, which remains after correction for age, gender, weight, diagnosis and femoral-tibial angle. Insert exchange was 4.73 times more likely in OA-patients compared to RA-patients. For every unit increase in BMI and weight the risk for insert exchange increases 1.40 times and 1.14 times, respectively. CONCLUSIONS: In conclusion we therefore advise against the use of thin PE inserts in modular TKA and recommend PE inserts with a minimal 8-mm thickness.Optimising joint reconstruction management in arthritis and bone tumour patient

    A taxonomy for community-based care programs focused on HIV/AIDS prevention, treatment, and care in resource-poor settings

    Get PDF
    Community-based care (CBC) can increase access to key services for people affected by HIV/AIDS through the mobilization of community interests and resources and their integration with formal health structures. Yet, the lack of a systematic framework for analysis of CBC focused on HIV/AIDS impedes our ability to understand and study CBC programs. We sought to develop taxonomy of CBC programs focused on HIV/AIDS in resource-limited settings in an effort to understand their key characteristics, uncover any gaps in programming, and highlight the potential roles they play. Our review aimed to systematically identify key CBC programs focused on HIV/AIDS in resource-limited settings. We used both bibliographic database searches (Medline, CINAHL, and EMBASE) for peer-reviewed literature and internet-based searches for gray literature. Our search terms were ‘HIV’ or ‘AIDS’ and ‘community-based care’ or ‘CBC’. Two co-authors developed a descriptive taxonomy through an iterative, inductive process using the retrieved program information. We identified 21 CBC programs useful for developing taxonomy. Extensive variation was observed within each of the nine categories identified: region, vision, characteristics of target populations, program scope, program operations, funding models, human resources, sustainability, and monitoring and evaluation strategies. While additional research may still be needed to identify the conditions that lead to overall program success, our findings can help to inform our understanding of the various aspects of CBC programs and inform potential logic models for CBC programming in the context of HIV/AIDS in resource-limited settings. Importantly, the findings of the present study can be used to develop sustainable HIV/AIDS-service delivery programs in regions with health resource shortages

    The effect of polyethylene thickness in fixed- and mobile-bearing total knee replacements

    No full text
    In this paper fixed- and mobile-bearing implants were simulated using a multibody dynamic model and a finite element model to investigate the contact pressure distribution in the ultra high molecular weight polyethylene tibial bearing component. The thickness of polyethylene varied from 6.8 to 12.3 mm and the polyethylene was modelled as a non-linear material. It was found that the contact pressure on the polyethylene decreased in the fixed-bearing implant when the thickness of polyethylene increased from 6.8 to 8 and 9.6 mm, but there was little further decrease in pressure with the increase of polyethylene thickness from 9.6 to 11.0 and 12.3 mm. In the mobile-bearing implant, no increase in contact pressure on the superior surface was found with the increase in the thickness of the polyethylene; however, the contact pressures on the inferior contact surface of the thicker designs were higher than those in the 6.8 mm design. The numerical results obtained in this paper are in good agreement with published experimental test results. Moreover, the paper presents a detailed pressure distribution on the tibial bearing component during a full gait cycle
    corecore