44 research outputs found

    Calibratin of Jaguar Aircraft structure retering rig

    Get PDF
    This document descries the - cali brati'on tests carried out on the fuel flow metering 4• used in fuelling and de-fuelling of. the Jaguar aircraft/Structures 'shop of HAL, Bangalore . The-results of the calibration tests are tabulated and are also shown graphically

    Calibration of Jaguar Aircraft Fuel Metering Rig , 1990

    Get PDF
    This document describes the calibration tests carried out on. The Fuel flo7i metering rig used iii fuelling and de-fuelling of the jag Aircraft of HAL, Bangalore. The results of the calibration tests Are tabulated add are also shown graphicall

    Design and Development of an Airblast Atomiser for the KAVERI engine and the sectoral combustor tests

    Get PDF
    This report deals with the design and development of an airblast atomiser for application in the KAVERI engine. Five atomisers of the chosen design were fabricated and tested at ambient conditions to determine the fuel spray SMD, patternation, cone angle and atomiser flow number. The atomiser performance parameters specified were achieved and hot tests carried out in the 90° combustor sector. The combustor pressure loss, exit temperature distribution, ignition and stability limits were evaluate

    Calibration of Pitot static probes for HAL, Koraput

    Get PDF
    This document explains the calibration procedure adopted to test the pitot-static probes, as required by HAL, Koraput . These probes (16 n.o)s were calibrated in the 254 min x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory . The probe calibration factor were determined and tabulated as show

    An isobar contour plot progrz

    Get PDF
    A computer program was developed to obtain ; isobar contours from the total pressure measurements at the engine face of an 1/3 scale model of an aircraft intake duct provided by ADA . A cubic spline method was used to interpolate the total pressure value between the measuring stations . The isobar contour plots were obtained for engine face Mach numbers\ud varying from 0.17 to 0 .43

    Calibration of Piston engine fuel rotameters- HAL-89

    Get PDF
    This-report provides details of calibration of fuel flow rotameters carried. out in the piston engine overhaul section of the Hindustan Aeronautics Limited, Bangalore - 560 017, The calibrated results have been tabulated and are also graphically shown

    Calibration of fuel totalizer of fuel accessories dept. HAL

    Get PDF
    This report provides details of calibration of Fuel Totalizer, carried out in the Fuel Accessories Department of Hindustan Aeronautics Ltd ., Bangalore. The calibrated result has been tabulated and is also shown graphically

    Calibration of Jaguar Aircraft Metering RIG

    Get PDF
    This document describes the calibration tests carried out on The fuel flow metering rig used in fuelling and de-fuelling Of the jaguar aircraft of HAL, Bangalore . The results of the Calibration tests are tabulated and are also shown graphicall

    Calibration of piston engine fuel rotameters HAL-92

    Get PDF
    This report provides details of calibration of fuel flow rotameters carried out in the piston engine overhaul section of the Hindustan Aeronautics Limited, Bangalore - 560 017. The calibrated results have tabulated and are also shown graphically

    Calibration of Fuel flow meter situated at Prototype Equipment HAL, Bangalore

    Get PDF
    This report provides details of calibration of the fuel flow meter (Totalizer) which was carried out in the prototype Equipment & Erection department of HAL (Main) Bangalore . The calibrated results are tahulatec and also shown graphicall