44 research outputs found
Calibratin of Jaguar Aircraft structure retering rig
This document descries the - cali brati'on tests carried out on the fuel flow metering 4• used in fuelling and de-fuelling of. the Jaguar aircraft/Structures 'shop of HAL, Bangalore .
The-results of the calibration tests are tabulated and are also shown graphically
Calibration of Jaguar Aircraft Fuel Metering Rig , 1990
This document describes the calibration tests carried out on. The Fuel flo7i metering rig used iii fuelling and de-fuelling of the jag Aircraft of HAL, Bangalore. The results of the calibration tests Are tabulated add are also shown graphicall
Design and Development of an Airblast Atomiser for the KAVERI engine and the sectoral combustor tests
This report deals with the design and development
of an airblast atomiser for application in the KAVERI
engine. Five atomisers of the chosen design were
fabricated and tested at ambient conditions to determine
the fuel spray SMD, patternation, cone angle
and atomiser flow number. The atomiser performance
parameters specified were achieved and hot tests
carried out in the 90° combustor sector. The combustor
pressure loss, exit temperature distribution, ignition
and stability limits were evaluate
Calibration of Pitot static probes for HAL, Koraput
This document explains the calibration procedure adopted to test the pitot-static probes, as required by HAL, Koraput . These probes (16 n.o)s were calibrated in the 254 min x 102 mm induction tunnel of the Aerodynamics Division of the Laboratory . The probe calibration factor were determined and tabulated as show
An isobar contour plot progrz
A computer program was developed to obtain ; isobar contours from the total pressure measurements at the engine face of an 1/3 scale model of an aircraft intake duct provided by ADA . A cubic spline method was used to interpolate the total pressure value between the measuring stations . The isobar contour plots were obtained for engine face Mach numbers\ud
varying from 0.17 to 0 .43
Calibration of Piston engine fuel rotameters- HAL-89
This-report provides details of calibration of fuel
flow rotameters carried. out in the piston engine overhaul
section of the Hindustan Aeronautics Limited,
Bangalore - 560 017, The calibrated results have been
tabulated and are also graphically shown
Calibration of fuel totalizer of fuel accessories dept. HAL
This report provides details of calibration of Fuel Totalizer, carried out in the Fuel Accessories Department of Hindustan Aeronautics Ltd ., Bangalore. The calibrated result has been tabulated and is also shown graphically
Calibration of Jaguar Aircraft Metering RIG
This document describes the calibration tests carried out on
The fuel flow metering rig used in fuelling and de-fuelling
Of the jaguar aircraft of HAL, Bangalore . The results of the
Calibration tests are tabulated and are also shown graphicall
Calibration of piston engine fuel rotameters HAL-92
This report provides details of calibration of fuel flow rotameters carried out in the piston engine overhaul section of the Hindustan Aeronautics Limited, Bangalore - 560 017. The calibrated results have tabulated and are also shown graphically
Calibration of Fuel flow meter situated at Prototype Equipment HAL, Bangalore
This report provides details of calibration of the fuel flow meter (Totalizer) which was carried out in the prototype Equipment & Erection department of HAL (Main) Bangalore . The calibrated results are tahulatec and also shown graphicall