30 research outputs found

    A new method to determine the elastopalstic properties of ductile materials by conical indentation

    Get PDF
    Based on load-displacement curves, indentation is widely used to extract the elastoplastic properties of materials. It is generally believed that such a measure is non-unique and a full stress-strain curve cannot be obtained using plural sharp and deep spherical indenters. In this paper we show that by introducing an additional dimensionless function of DA / A (the ratio of residual area to the area of an indenter profile) in the reverse analysis, the elastoplastic properties of several unknown materials that exhibit visually indistinguishable load-displacement curves can be uniquely determined with a sharp indentation

    A New Mathematical Numerical Model to Evaluate the Risk of Thrombosis in Three Clinical Ventricular Assist Devices

    No full text
    (1) Background: Thrombosis is the main complication in patients supported with ventricular assist devices (VAD). Models that accurately predict the risk of thrombus formation in VADs are still lacking. When VADs are clinically assisted, their complex geometric configuration and high rotating speed inevitably generate complex flow fields and high shear stress. These non-physiological factors can damage blood cells and proteins, release coagulant factors and trigger thrombosis. In this study, a more accurate model for thrombus assessment was constructed by integrating parameters such as shear stress, residence time and coagulant factors, so as to accurately assess the probability of thrombosis in three clinical VADs. (2) Methods: A mathematical model was constructed to assess platelet activation and thrombosis within VADs. By solving the transport equation, the influence of various factors such as shear stress, residence time and coagulation factors on platelet activation was considered. The diffusion equation was applied to determine the role of activated platelets and substance deposition on thrombus formation. The momentum equation was introduced to describe the obstruction to blood flow when thrombus is formed, and finally a more comprehensive and accurate model for thrombus assessment in patients with VAD was obtained. Numerical simulations of three clinically VADs (CH-VAD, HVAD and HMII) were performed using this model. The simulation results were compared with experimental data on platelet activation caused by the three VADs. The simulated thrombogenic potential in different regions of MHII was compared with the frequency of thrombosis occurring in the regions in clinic. The regions of high thrombotic risk for HVAD and HMII observed in experiments were compared with the regions predicted by simulation. (3) Results: It was found that the percentage of activated platelets within the VAD obtained by solving the thrombosis model developed in this study was in high agreement with the experimental data (r² = 0.984), the likelihood of thrombosis in the regions of the simulation showed excellent correlation with the clinical statistics (r² = 0.994), and the regions of high thrombotic risk predicted by the simulation were consistent with the experimental results. Further study revealed that the three clinical VADs (CH-VAD, HVAD and HMII) were prone to thrombus formation in the inner side of the secondary flow passage, the clearance between cone and impeller, and the corner region of the inlet pipe, respectively. The risk of platelet activation and thrombus formation for the three VADs was low to high for CH-VAD, HVAD, and HM II, respectively. (4) Conclusions: In this study, a more comprehensive and accurate thrombosis model was constructed by combining parameters such as shear stress, residence time, and coagulation factors. Simulation results of thrombotic risk received with this model showed excellent correlation with experimental and clinical data. It is important for determining the degree of platelet activation in VAD and identifying regions prone to thrombus formation, as well as guiding the optimal design of VAD and clinical treatment

    ISpliter: an intelligent and automatic surface mesh generator using neural networks and splitting lines

    No full text
    Abstract In this paper, we present a novel surface mesh generation approach that splits B-rep geometry models into isotropic triangular meshes based on neural networks and splitting lines. In the first stage, a recursive method is designed to generate plentiful data to train the neural network model offline. In the second stage, the implemented mesh generator, ISpliter, maps each surface patch into the parameter plane, and then the trained neural network model is applied to select the optimal splitting line to divide the patch into subdomains continuously until they are all triangles. In the third stage, ISpliter remaps the 2D mesh back to the physical space and further optimizes it. Several typical cases are evaluated to compare the mesh quality generated by ISpliter and two baselines, Gmsh and NNW-GridStar. The results show that ISpliter can generate isotropic triangular meshes with high average quality, and the generated meshes are comparable to those generated by the other two software under the same configuration

    The Impact of a New Arterial Intravascular Pump on Aorta Hemodynamic Surrounding: A Numerical Study

    No full text
    Purpose: The purpose of this study was to investigate the impact of a new arterial intravascular pump on the hemodynamic surroundings within the aorta. Methods: A new arterial intravascular pump was placed in the descending aorta, and the effects of three positions within the aorta, as well as the number (n = 1 to 3) of pumps, on arterial flow features, organ perfusion, and blood trauma were investigated using a computational fluid dynamics (CFD) method. Results: It was found that as the pump position was moved backward, the perfusion in the three bifurcated vessels of the aorta arch increased and the pump suction flow decreased, resulting in a reduced high shear stress and decreased residence time in the three branches of the aortic arch. The further posterior the location of the pump, the better the blood flow perfusion to the kidneys, while the perfusion at the bifurcation of the abdominal aorta was reduced, due to the pump suction effect. Compared to the condition with single pump support, the multi-pump assist model can significantly reduce the pump rotating speed, while keeping the same flow patterns, leading to a decreased volume of high shear stress and flow loss. When increasing the number of pumps, the perfusion to the three branches of the aortic arch increased, accompanied by a diminished residence time, and the perfusion to the other aortic branches was decreased. However, the perfusion to the other aortic branches, especially for the renal arteries and even under a three-pump condition, was close to that without pump assistance. Conclusion: The placement of an intravascular pump near the beginning of the suprarenal abdominal aorta was considered the optimal location, in order to improve the hemodynamic surroundings. Increasing the number of pumps can significantly reduce the rotational speed, while maintaining the same flowrate, with a decreased fluid energy loss and a reduced high shear stress. This arterial intravascular pump can effectively improve renal blood flow

    Green synthesis of graphene with the assistance of modified lignin and its application in anticorrosive waterborne epoxy coatings

    No full text
    In this work, the lignin, undervalued sustainable biomaterials, was modified and utilized to produce low-defect graphene from pristine graphite by exfoliation in water. The non-covalently interactions between modified lignin (lignin-OH) and graphene were confirmed to improve the dispersion and stability of the nanocomposites. As an additive, the lignin-OH/graphene dispersion was added into waterborne epoxy resin to enhance anticorrosion of the nanocomposites. By the analysis of the electrochemical impedance spectroscopy (EIS), the nanocomposite coatings displayed higher impedance value at low frequency and bigger phase angle at high frequency with respect to the pure epoxy coatings. By fitting with equivalent circuits, the coating resistance (R-c) and charge-transfer resistance (R-ct) of 0.5% lignin-OH/graphene/WEP coatings are one or two orders of magnitude higher than that of pure epoxy coatings. The better anticorrosion effect should be attributed to well-dispersed graphene with the assistance of lignin-OH which generated the "labyrinth effect" of corrosive route. Therefore, this work provides a new way to enhance anticorrosive ability of waterborne epoxy resin, and it also gives a noteworthy strategy for development of biomaterial lignin's high value-added applications

    High shear induces platelet dysfunction leading to enhanced thrombotic propensity and diminished hemostatic capacity

    No full text
    Thrombosis and bleeding are devastating adverse events in patients supported with blood-contacting medical devices (BCMDs). In this study, we delineated that high non-physiological shear stress (NPSS) caused platelet dysfunction that may contribute to both thrombosis and bleeding. Human blood was subjected to NPSS with short exposure time. Levels of platelet surface GPIbα and GPVI receptors as well as activation level of GPIIb/IIIa in NPSS-sheared blood were examined with flow cytometry. Adhesion of sheared platelets on fibrinogen, von Willibrand factor (VWF), and collagen was quantified with fluorescent microscopy. Ristocetin- and collagen-induced platelet aggregation was characterized by aggregometry. NPSS activated platelets in a shear and exposure time-dependent manner. The number of activated platelets increased with increasing levels of NPSS and exposure time, which corresponded well with increased adhesion of sheared platelets on fibrinogen. Concurrently, NPSS caused shedding of GPIbα and GPVI in a manner dependent on shear and exposure time. The loss of intact GPIbα and GPVI increased with increasing levels of NPSS and exposure time. The number of platelets adhered on VWF and collagen decreased with increasing levels of NPSS and exposure time, respectively. The decrease in the number of platelets adhered on VWF and collagen corresponded well with the loss in GPIbα and GPVI on platelet surface. Both ristocetin- and collagen-induced platelet aggregation in sheared blood decreased with increasing levels of NPSS and exposure time. The study clearly demonstrated that high NPSS causes simultaneous platelet activation and receptor shedding, resulting in a paradoxical effect on platelet function via two distinct mechanisms. The results from the study suggested that the NPSS could induce the concurrent propensity for both thrombosis and bleeding in patients
    corecore