20 research outputs found

    Dissociative Adsorption of H2 on the H/Si(100) Surface: The Effect of Intradimer pi-Bonding Disruption

    Get PDF
    We have studied dissociative H2 adsorption on the H/Si(100) surface by means of pseudopotential density functional theory calculations. This work is directly motivated by the observations of Biederman et al. [Phys. Rev. Lett., 83, 1810 (1999)]: "H2 adsorption is significantly promoted in an interdimer configuration of two adjacent singly occupied dimers." We find that there is no adsorption barrier on the local site where two quasi-free dangling bonds are available; the adsorption energy is estimated to be 2.6 eV per H2 within the local density approximation. We present maximally localized Wannier functions that clearly illustrate the behavior of dangling orbitals upon the approach of H2. The results suggest that intradimer pi-bonding disruption is crucial for the significant promotion of H2 adsorption on Si(100)

    Modeling the Effect of Cell Variation on the Performance of a Lithium-Ion Battery Module

    No full text
    Owing to the variation between lithium-ion battery (LIB) cells, early discharge termination and overdischarge can occur when cells are coupled in series or parallel, thereby triggering a decrease in LIB module performance and safety. This study provides a modeling approach that considers the effect of cell variation on the performance of LIB modules in energy storage applications for improving the reliability of the power quality of energy storage devices and efficiency of the energy system. Ohm’s law and the law of conservation of charge were employed as the governing equations to estimate the discharge behavior of a single strand composing of two LIB cells connected in parallel based on the polarization properties of the electrode. Using the modeling parameters of a single strand, the particle swarm optimization algorithm was adopted to predict the discharge capacity and internal resistance distribution of 14 strands connected in series. Based on the model of the LIB strand to predict the discharge behavior, the effect of cell variation on the deviation of the discharge termination voltage and depth of discharge imbalance was modeled. The validity of the model was confirmed by comparing the experimental data with the modeling results

    Modeling the Effects of the Cathode Composition of a Lithium Iron Phosphate Battery on the Discharge Behavior

    No full text
    This paper reports a modeling methodology to predict the effects on the discharge behavior of the cathode composition of a lithium iron phosphate (LFP) battery cell comprising a LFP cathode, a lithium metal anode, and an organic electrolyte. A one-dimensional model based on a finite element method is presented to calculate the cell voltage change of a LFP battery cell during galvanostatic discharge. To test the validity of the modeling approach, the modeling results for the variations of the cell voltage of the LFP battery as a function of time are compared with the experimental measurements during galvanostatic discharge at various discharge rates of 0.1C, 0.5C, 1.0C, and 2.0C for three different compositions of the LFP cathode. The discharge curves obtained from the model are in good agreement with the experimental measurements. On the basis of the validated modeling approach, the effects of the cathode composition on the discharge behavior of a LFP battery cell are estimated. The modeling results exhibit highly nonlinear dependencies of the discharge behavior of a LFP battery cell on the discharge C-rate and cathode composition

    Modeling of the Electrical and Thermal Behaviors of an Ultracapacitor

    No full text
    This paper reports a modeling methodology to predict the electrical and thermal behaviors of a 2.7 V/650 F ultracapacitor (UC) cell from LS Mtron Ltd. (Anyang, Korea). The UC cell is subject to the charge/discharge cycling with constant-current between 1.35 V and 2.7 V. The charge/discharge current values examined are 50, 100, 150, and 200 A. A three resistor-capacitor (RC) parallel branch model is employed to calculate the electrical behavior of the UC. The modeling results for the variations of the UC cell voltage as a function of time for various charge/discharge currents are in good agreement with the experimental measurements. A three-dimensional thermal model is presented to predict the thermal behavior of the UC. Both of the irreversible and reversible heat generations inside the UC cell are considered. The validation of the three-dimensional thermal model is provided through the comparison of the modeling results with the experimental infrared (IR) image at various charge/discharge currents. A zero-dimensional thermal model is proposed to reduce the significant computational burden required for the three-dimensional thermal model. The zero-dimensional thermal model appears to generate the numerical results accurate enough to resolve the thermal management issues related to the UC for automotive applications without relying on significant computing resources

    Modeling the Performance of a Zinc/Bromine Flow Battery

    No full text
    The zinc/bromine (Zn/Br2) flow battery is an attractive rechargeable system for grid-scale energy storage because of its inherent chemical simplicity, high degree of electrochemical reversibility at the electrodes, good energy density, and abundant low-cost materials. It is important to develop a mathematical model to calculate the current distributions in a Zn/Br2 flow cell in order to predict such quantities as current, voltage, and energy efficiencies under various charge and discharge conditions. This information can be used to design both of bench and production scale cells and to select the operating conditions for optimum performance. This paper reports a modeling methodology to predict the performance of a Zn/Br2 flow battery. The charge and discharge behaviors of a single cell is calculated based on a simple modeling approach by considering Ohm’s law and charge conservation on the electrodes based on the simplified polarization characteristics of the electrodes. An 8-cell stack performance is predicted based on an equivalent circuit model composed of the single cells and the resistances of the inlet and outlet streams of the positive and negative electrolytes. The model is validated by comparing the modeling results with the experimental measurements
    corecore