24 research outputs found

    Influence of slope angle on pore pressure generation and kinematics of pyroclastic flows : insights from laboratory experiments

    Full text link
    The influence of slope angle on pore pressure generation and kinematics of fines-rich pyroclastic flows was investigated through laboratory experiments. Granular flows were generated by the release of a column of fine glass beads (d=0.08 mm) in an inclined channel (0-30 degrees). The granular column could be fluidized while the channel base was either smooth or made rough by glued beads of 3 mm diameter. Pore pressure measurements reveal that the degree of autofluidization, caused by air escaping from the substrate interstices into which flow particles settled, was high at all slope angles. Flow runout increase due to autofluidization, however, was reduced at slope angle higher than similar to 12 degrees because of the occurrence of a strong deceleration phase that limited the flow duration. This is probably caused by the combination of flow head thinning at increased slope angle and settling of particles into the substrate interstices until the flow ran out of mass. Analysis of high-speed videos suggests that ingestion of ambient air at the flow front did not occur, even on steep slopes of 30 degrees. Experiments at inclinations close to (25 degrees) or slightly higher (30 degrees) than the repose angle of the granular material (28.5 degrees) revealed the formation of a thin basal deposit that was then eroded as the flow thickness and velocity gradually decreased. Our study suggests that air escape from substrate interstices in nature can be a significant external cause of pore pressure generation that favors low energy dissipation and long runout distances of pyroclastic flows on moderate topographies

    Traitement d'eaux résiduaires industrielles par oxydation avancée combinée avec un éjecteur

    Full text link
    National audienceL’eau, grĂące Ă  ses propriĂ©tĂ©s physicochimiques intĂ©ressantes, est utilisĂ©e dans de nombreux procĂ©dĂ©s en tant que solvant, fluide caloporteur ou fluide de lavage. Or, les normes concernant les rejets aqueux sont de plus en plus strictes, ce qui impose aux industriels une amĂ©lioration constante de leurs outils de traitement.Ce projet a pour objectif la mise en place et l’étude d’une mĂ©thode de traitement par un procĂ©dĂ© d’oxydation avancĂ©e couplĂ© avec un Ă©jecteur tubulaire. Les procĂ©dĂ©s d’oxydation avancĂ©e regroupent l’ensemble des techniques basĂ©es sur la gĂ©nĂ©ration de radicaux hydroxyles. Ces radicaux, trĂšs rĂ©actifs et peu sĂ©lectifs, permettent de dĂ©grader un trĂšs grand nombre de polluants organiques. Les radicaux sont ici gĂ©nĂ©rĂ©s par interaction entre l’ozone et du peroxyde d’hydrogĂšne.L’éjecteur est un contacteur gaz / liquide permettant d’obtenir une surface de contact trĂšs Ă©levĂ©e entre les deux phases. Ce contacteur est indiquĂ© dans le cas de rĂ©actions rapides oĂč le transfert de matiĂšre est le phĂ©nomĂšne limitant. Ici, les cinĂ©tiques rĂ©actionnelles importantes induisent une forte demande en ozone. Le calcul du nombre de Hatta montre que l’éjecteur semble ĂȘtre le contacteur permettant une efficacitĂ© de transfert maximale.Dans un premier temps, une Ă©tape de mise en place de l’installation et de comprĂ©hension des phĂ©nomĂšnes a Ă©tĂ© rĂ©alisĂ©e. Le phĂ©nol a Ă©tĂ© utilisĂ© comme polluant modĂšle. Ces expĂ©riences ont montrĂ© que les Ă©volutions du transfert d’ozone et de la minĂ©ralisation du phĂ©nol sont expliquĂ©es notamment par l’évolution de la composition de la solution et les Ă©quilibres acido-basiques des espĂšces prĂ©sentes. Ces premiers rĂ©sultats ont aussi montrĂ© l’efficacitĂ© de la mĂ©thode, tant au point de vue de l’élimination du polluant (phĂ©nol entiĂšrement dĂ©gradĂ©) qu’au point de vue du transfert d’ozone ( > 90 % tant qu’il y a du phĂ©nol en solution).Dans un deuxiĂšme temps, l’influence de paramĂštres opĂ©ratoires tels que le pH, la tempĂ©rature, le dĂ©bit gazeux et les concentrations en rĂ©actifs (ozone, phĂ©nol, peroxyde d’hydrogĂšne) a Ă©tĂ© Ă©tudiĂ©e avec pour objectif de trouver les conditions optimales afin de dĂ©grader rapidement le polluant en ayant un taux de transfert d’ozone maximum. Il est ainsi apparu qu’une tempĂ©rature et un pH plus Ă©levĂ©s permettent d’obtenir un traitement plus rapide avec une consommation en ozone moindre

    Utilisation d'un contacteur gaz/liquide type éjecteur tubulaire pour l'ozonation de dérivés de l'acide cinnamique

    Full text link
    National audienceLa teneur Ă©levĂ©e en composĂ©s phĂ©noliques de certains effluents d’origine agro-alimentaire, tels que les margines, pose un problĂšme environnemental. Du fait de leur toxicitĂ© et de leur activitĂ© bactĂ©ricide, ces composĂ©s ne peuvent ĂȘtre rejetĂ©s dans le milieu naturel, et leur traitement par voie classique, comportant une Ă©tape de dĂ©gradation biologique est impossible. L’objectif de cette Ă©tude est de proposer un procĂ©dĂ© de prĂ©traitement de ces composĂ©s basĂ© sur l’ozonation. Le but est d’obtenir un procĂ©dĂ© efficace en termes d’élimination du polluant, de transfert d’ozone dans l’eau et de capacitĂ© de traitement (dĂ©bit de l’effluent et temps de traitement). Pour cela, un composĂ© modĂšle, l’acide p-coumarique, a Ă©tĂ© utilisĂ©. Dans un premier temps, la constante de vitesse de l’ozonation de ce composĂ© a Ă©tĂ© dĂ©terminĂ©e en fonction du pH grĂące Ă  la mĂ©thode des rĂ©actions compĂ©titives. Il est apparu que la rĂ©action est rapide et dĂ©pend fortement du pH : la constante de vitesse varie entre 4,6.10^3 L mol-1 s-1 (Ă  pH 2) et 5,5.10^9 L mol-1 s-1 (Ă  pH 10). Puis, un contacteur gaz/liquide adaptĂ© Ă  un rĂ©gime rĂ©actionnel de type diffusionnel (Ha > 3), l’éjecteur tubulaire, a Ă©tĂ© utilisĂ© pour rĂ©aliser le transfert de matiĂšre lors de l’ozonation. Le procĂ©dĂ© mis en place a alors permis d’éliminer plus de 57 % du polluant, avec un taux de transfert d’ozone supĂ©rieur Ă  98 %, pour un temps de contact entre les phases de l’ordre de la seconde et un dĂ©bit d’effluent liquide de 0,8 m3 h-1

    Developing a new advanced treatment technique for micropollutants removal from water and wastewater

    Full text link
    This is the final version of the following article : Developing a new advanced treatment technique for micropollutants removal from water and wastewater, which has been published in final form at http://www.lestudium-ias.com/content/developing-new-advanced-treatment-technique-micropollutants-removal-water-and-wastewaterInternational audienceNovel cost-efficient Fenton-like catalysts were prepared for the degradation of organic molecules in aqueous solutions. Porous activated carbons (ACs) were directly impregnated with Fe2+ solutions of different concentrations using the wet impregnation method. Their efficiency, as Fenton-like catalysts, was studied. Photo-Fenton tests were performed to establish the performance of the prepared Fe-impregnated ACs in relation to the degradation of organic micropollutants in aqueous solution, under different conditions. Photo-catalytic tests were carried out by means of a laboratory photo-reactor. The influence of several parameters such as solution pH value, initial concentration of the model pollutant, and hydrogen peroxide dose on the process performance was investigated. The ACs and prepared catalysts were characterized by nitrogen adsorption-desorption isotherms at 77K, FTIR, SEM, and thermogravimetric analyses. The total Fe content of the synthesized composites was estimated by the phenanthroline method using UV-Vis spectrophotometry. Photo-catalytic tests were performed in monosolute or mix solutions of MPs in order to compare the efficiency of various conventional AOPs with that of photo-Fenton-peroxone process. The results show an increase in the degradation rate in case of the heterogeneous photo-Fenton-peroxone process

    Couplage de procédés d'oxydation avancée et d'un éjecteur tubulaire pour le traitement d'eaux résiduaires industrielles

    Full text link
    International audienceL’utilisation de l’eau dans de nombreux procĂ©dĂ©s entraĂźne sa pollution par diffĂ©rents composĂ©s. La politique actuelle de prĂ©servation de l’environnement tend Ă  traiter le plus en amont possible ces rejets. De nombreuses industries doivent alors, afin de respecter des normes de rejet de plus en plus sĂ©vĂšres, se munir d’outils de traitement de leurs eaux rĂ©siduaires.Les procĂ©dĂ©s d’oxydation avancĂ©e sont des techniques efficaces pour le traitement de nombreux composĂ©s dissous. Ces procĂ©dĂ©s sont basĂ©s sur la gĂ©nĂ©ration de radicaux hydroxyles HO‱, espĂšce permettant d’oxyder un trĂšs grand nombre de polluants organiques.L’objectif de l’étude est de mettre au point, Ă  l’échelle pilote, un outil de dĂ©pollution basĂ© sur les procĂ©dĂ©s d’oxydation avancĂ©e. Les radicaux HO‱ sont gĂ©nĂ©rĂ©s par dĂ©composition de l’ozone dans l’eau. Dans cette Ă©tude, trois couplages sont utilisĂ©s : ozone/UV, ozone/H2O2 et ozone/UV/H2O2, permettant la formation des HO‱ par une succession de rĂ©actions radicalaires.Le transfert du gaz dans l’effluent, aspect important de l’étude, est effectuĂ© dans un rĂ©acteur, constituĂ© d’un Ă©jecteur tubulaire prolongĂ© par un tube droit (L = 1,07 m ; Ø = 2 cm). Ce contacteur gaz/liquide, encore peu utilisĂ© dans le monde industriel, offre une surface de contact importante entre les deux phases et ainsi un transfert efficace de l’ozone vers l’effluent Ă  traiter. Il permet de rĂ©pondre Ă  la forte demande en ozone des procĂ©dĂ©s d’oxydation avancĂ©e utilisĂ©s.Lors de cette Ă©tude, plusieurs rĂ©ponses du systĂšme sont mesurĂ©es : les Ă©volutions en fonction du temps de la quantitĂ© de polluant cible et de ses sous produits (quantitĂ©s mesurĂ©es par HPLC), de la demande chimique en oxygĂšne (DCO), du carbone organique total (COT), du pH et du ratio de transfert d’ozone.Une sĂ©rie d’expĂ©rience a Ă©tĂ© rĂ©alisĂ©e en utilisant le phĂ©nol comme polluant modĂšle. Les Ă©tudes dĂ©jĂ  rĂ©alisĂ©es Ă  propos de l’élimination de ce composĂ© permettent de juger de l’efficacitĂ© des mĂ©thodes testĂ©es.Les expĂ©riences ont montrĂ© que, quelle que soit la technique utilisĂ©e, l’élimination de ce composĂ© est complĂšte, et que les abattements de DCO et de COT sont supĂ©rieurs Ă  90 %. Il reste en solution des composĂ©s de faible masse molĂ©culaire (acides carboxyliques lĂ©gers), facilement Ă©liminables par traitement biologique. Le ratio de transfert d’ozone est quand Ă  lui trĂšs Ă©levĂ© (> 90 %) tant qu’il reste en solution des polluants en quantitĂ© non nĂ©gligeable.Ainsi, les techniques de traitement Ă©tudiĂ©es semblent efficaces tant pour l’élimination du polluant cible (le phĂ©nol), que pour le rendement de transfert de l’ozone. Par la suite, les effets de diffĂ©rents paramĂštres (tempĂ©rature, pH, dĂ©bits) sur l’efficacitĂ© du procĂ©dĂ© seront Ă©tudiĂ©s, et l’élimination d’autres polluants organiques par ces mĂ©thodes sera testĂ©e

    Use of an ejector for phenol containing water treatment by ozonation

    Full text link
    International audienceMass transfer of ozone in aqueous phase is a major aspect of ozonation and advanced oxidation processes. The aim of this study is to compare the performances of an ejector with those of a more traditional gas/liquid contactor: a bubble column. The hydrodynamic study showed that the volumetric mass transfer coefficient of the ejector (KLa = 7.2 × 10−2 to 1.35 × 10−1 s−1) was greater than that of the bubble column's (KLa = 1.5 × 10−2 to 2.8 × 10−2 s−1). Very important differences in the values of the residence time and gas retention rate were also observed. A study of phenol degradation was performed. Due to its specifications the ejector is very efficient when the kinetics of reaction is fast (diffusion-controlled regime). In both semi-batch and open circuits, the phenol was quickly eliminated and the ozone transfer was very high (up to 98%). It is to be noted that these results were obtained for a processing time of approximately 1 s
    corecore