4 research outputs found

    Left atrial appendage closure with WATCHMAN in Asian patients: 2 year outcomes from the WASP registry

    Get PDF
    Background: Left atrial appendage closure is a non-pharmacological alternative for stroke prevention in high-risk non-valvular atrial fibrillation patients, but has not been widely studied in Asian patients. The prospective WASP registry assessed real-world outcomes for patients undergoing WATCHMAN implant in the Asia-Pacific region. Methods: Data were collected from consecutive patients across 9 centres. Major endpoints included procedural success, safety and long-term outcomes including occurrence of bleeding, stroke/transient ischaemic attack/systemic embolism and all-cause mortality. Results: Subjects (n = 201) had a mean age of 70.8 ± 9.4 years, high stroke risk (CHA2DS2-VASc: 3.9 ± 1.7), elevated bleeding risk (HAS-BLED: 2.1 ± 1.2) with 53% patients from Asian countries. Successful implantation occurred in 98.5% of patients; 7-day device/procedure-related SAE rate was 3.0%. After 2 years of follow-up, the rates of ischaemic stroke/TIA/SE and major bleeding were 1.9 and 2.2 per 100-PY, respectively, representing relative reductions of 77% and 49% versus expected rates per risk scores. The relative risk reductions versus expected rates were more pronounced in Asians vs. Non-Asians (89% vs 62%; 77% vs 14%). Other significant findings included larger mean LAA ostium diameter for Asians vs. Non-Asians (23.4 ± 4.1 mm vs. 21.2 ± 3.2 mm, p < 0.001) and hence requirement for larger median device size (27 mm for Asians, 24 mm for non-Asians [p < 0.0001]). Conclusion: Real-world experience of left atrial appendage closure with WATCHMAN has demonstrated low peri-procedural risk, and long-term efficacy for stroke and bleeding prevention in a primarily Asian cohort.Karen P. Phillips, Teguh Santoso, Prashanthan Sanders, Jeffrey Alison, Jason Leung Kwai Chan, Hui-Nam Pak, Mann Chandavimol, Kenneth M. Stein, Nicole Gordon, Omar Bin Razal

    Percutaneous transvenous mitral annuloplasty - Initial human experience with device implantation in the coronary sinus

    No full text
    Background - Mitral annuloplasty is the most common surgical procedure performed for ischemic mitral regurgitation (MR). Surgical mitral annuloplasty is limited by morbidity, mortality, and MR recurrence. We evaluated the safety and feasibility of a transvenous catheter-delivered implantable device to provide a percutaneous alternative to surgical mitral annuloplasty. Methods and Results - Five patients with chronic ischemic MR underwent percutaneous transvenous implantation of an annuloplasty device in the coronary sinus. Implantation was successful in 4 patients. Baseline MR in the entire group was grade 3.0 +/- 0.7 and was reduced to grade 1.6 +/- 1.1 at the last postimplantation visit when the device was intact or the last postprocedural visit in the patient in whom the device was not successfully implanted. Separation of the bridge section of the device occurred in 3 of 4 implanted devices and was detected at 28 to 81 days after implantation. There were no postprocedural device-related complications. Conclusions - Percutaneous implantation of a device intended to remodel the mitral annulus is feasible. Initial experience suggests a possible favorable effect on MR. Percutaneous transvenous mitral annuloplasty warrants further evaluation as a less invasive alternative to surgical annuloplasty
    corecore