35 research outputs found

    Usefulness of computed tomography based three-dimensional reconstructions to assess the critical shoulder angle.

    Full text link
    BACKGROUND: The critical shoulder angle (CSA) is a radiographic measurement that provides an assessment of both glenoid inclination and acromial length. Higher values may correlate with the presence of rotator cuff tears. However, it is difficult to obtain a high-quality true anteroposterior (AP) radiograph of the shoulder, with any excess scapular version or flexion/extension resulting in deviation from the true CSA value. Three-dimensional (3D) bony reconstructions of computed tomography (CT) shoulder scans may be able to be rotated to obtain a similar view to that of true AP radiographs. AIM: To compare CSA measurements performed on 3D bony CT reconstructions, with those on corresponding true AP radiographs. METHODS: CT shoulder scans were matched with true AP radiographs that were classified as either Suter-Henninger type A or C quality. 3D bony reconstructions were segmented from the CT scans, and rotated to replicate an ideal true AP view. Two observers performed CSA measurements using both CT and radiographic images. Measurements were repeated after a one week interval. Reliability was assessed using intraclass correlation coefficients (ICCs) and Bland-Altman plots [bias, limits of agreement (LOA)]. RESULTS: Twenty CT shoulder scans were matched. The mean CSA values were 32.55° (± 4.26°) with radiographs and 29.82° (± 3.49°) with the CT-based method [mean difference 2.73° (± 2.86°); P < 0.001; bias +2.73°; LOA -2.17° to +7.63°]. There was a strong correlation between the two methods (r = 0.748; P < 0.001). Intra-observer reliability was similar, but the best intra-observer values were achieved by the most experienced observer using the CT-based method [ICC: 0.983 (0.958-0.993); bias +0.03°, LOA -1.28° to +1.34°]. Inter-observer reliability was better with the CT-based method [ICC: 0.897 (0.758-0.958), bias +0.24°, LOA -2.93° to +3.41°]. CONCLUSION: The described CT-based method may be a suitable alternative for critical shoulder angle measurement, as it overcomes the difficulty in obtaining a true AP radiographic view

    Is Stand-Alone Anterior Lumbar Interbody Fusion a Safe and Efficacious Treatment for Isthmic Spondylolisthesis of L5-S1?

    Full text link
    STUDY DESIGN: A systematic review. OBJECTIVE: The objective of this study was to determine the safety and efficacy of stand-alone anterior lumbar interbody fusion (sa-ALIF) for the treatment of symptomatic isthmic spondylolisthesis of L5-S1 by assessing the level of available clinical and radiographic evidence. METHODS: A systematic review utilizing Medline, Embase, and Scopus online databases was undertaken. Clinical, radiographic, and adverse outcome data were extracted for the relevant isthmic spondylolisthesis cases with the intention of undertaking a meta-analysis. RESULTS: The database search between January 1980 and December 2015 yielded 23 articles that concerned sa-ALIF for isthmic spondylolisthesis of L5-S1. Only in 9 of the 23 articles data could be extracted specific to sa-ALIF for isthmic spondylolisthesis of L5-S1. There was considerable inconsistency in the standards for reporting outcomes of the surgery due to which meta-analysis could not be undertaken, and hence each article was reviewed. CONCLUSIONS: There was insufficient evidence to support the safety and efficacy of sa-ALIF for the treatment of isthmic spondylolisthesis of L5-S1. Although sa-ALIF is widely documented in the literature, there was insufficient evidence to support its use in treating this specific pathology. The unique pathological and anatomical situation that isthmic spondylolisthesis of L5-S1 presents must be recognized and its treatment with sa-ALIF should be well thought out

    The Role of Sacral Slope in the Progression of a Bilateral Spondylolytic Defect at L5 to Spondylolisthesis: A Biomechanical Investigation Using Finite Element Analysis

    Full text link
    © The Author(s) 2017. Study Design: A biomechanical study using finite element analysis. Objectives: The main objective of this study was to investigate the role of sacral slope in the progression of a L5 bilateral spondylolytic defect to spondylolisthesis. Methods: A 3-dimensional model of lumbosacral spine was built using computed tomography (CT) data procured from an anonymized healthy male subject. The segmented CT data was manipulated to generate 3 more models representing L5 bilateral spondylolytic defect with normal sacral slope (SS), sacral slope increased by 10° (SS+10), and sacral slope decreased by 10° (SS-10). The 3D models were imported into finite element modelling software Strand7 for preprocessing, running nonlinear static solves, and postprocessing of the results. Results: Directional biomechanical instabilities were induced in the lumbosacral spine as a result of changes in the L5-S1 disc shape secondary to the changes in sacral slope. Compared with the normal L5 lytic model, wedging of the L5-S1 disc (SS+10) resulted in a significantly greater range of motion in flexion (18% ↑) but extension motion characteristics were similar. Conversely, flattening of the L5-S1 disc (SS-10) resulted in a significantly greater range of motion in extension (16% ↑) but flexion motion characteristics were similar to that of the normal L5 lytic model. Conclusions: Variations in sacral slope while preserving the L5-S1 mid-disc height and orientation of the L5 vertebra resulted in variations in the L5-S1 disc shape. The results suggest that for such extremities in the L5-S1 disc shape different pathomechanisms exist for the progression of the L5 lytic defect to spondylolisthesis

    Mild (not severe) disc degeneration is implicated in the progression of bilateral L5 spondylolysis to spondylolisthesis

    Full text link
    © 2018 The Author(s). Background: Spondylolytic (or lytic) spondylolisthesis is often associated with disc degeneration at the index-level; however, it is not clear if disc degeneration is the cause or the consequence of lytic spondylolisthesis. The main objective of this computed tomography based finite element modelling study was to examine the role of different grades of disc degeneration in the progression of a bilateral L5-lytic defect to spondylolisthesis. Methods: High-resolution computed tomography data of the lumbosacral spine from an anonymised healthy male subject (26 years old) were segmented to build a 3D-computational model of an INTACT L1-S1 spine. The INTACT model was manipulated to generate four more models representing a bilateral L5-lytic defect and the following states of the L5-S1 disc: nil degeneration (NOR LYTIC), mild degeneration (M-DEG LYTIC), mild degeneration with 50% disc height collapse (M-DEG-COL LYTIC), and severe degeneration with 50% disc height collapse(S-COL LYTIC). The models were imported into a finite element modelling software for pre-processing, running nonlinear-static solves, and post-processing of the results. Results: Compared with the baseline INTACT model, M-DEG LYTIC model experienced the greatest increase in kinematics (Fx range of motion: 73% ↑, Fx intervertebral translation: 53%↑), shear stresses in the annulus (Fx anteroposterior: 163%↑, Fx posteroanterior: 31%↑), and strain in the iliolumbar ligament (Fx: 90%↑). The S-COL LYTIC model experienced a decrease in mobility (Fx range of motion: 48%↓, Fx intervertebral translation: 69%↓) and an increase in normal stresses in the annulus (Fx Tensile: 170%↑; Fx Compressive: 397%↑). No significant difference in results was noted between M-DEG-COL LYTIC and S-COL LYTIC models. Conclusions: In the presence of a bilateral L5 spondylolytic defect, a mildly degenerate index-level disc experienced greater intervertebral motions and shear stresses compared with a severely degenerate index-level disc in flexion and extension bending motions. Disc height collapse, with or without degenerative changes in the stiffness properties of the disc, is one of the plausible re-stabilisation mechanisms available to the L5-S1 motion segment to mitigate increased intervertebral motions and shear stresses due to a bilateral L5 lytic defect

    In Vivo 3D MRI Measurement of Tumour Volume in an Orthotopic Mouse Model of Prostate Cancer

    Full text link
    © The Author(s) 2019. Prostate cancer (CaP) is the most commonly diagnosed cancer in males in western countries. Orthotopic implantation is considered as an ideal xenograft model for CaP study, and noninvasive measurement of tumor volume changes is important for monitoring responses to anticancer therapies. In this study, the T2-weighted fast spin echo sequence magnetic resonance imaging (MRI) was performed on a CaP orthotopic non-obese diabetic/severe combined immunodeficiency (NOD/SCID) mouse model weekly for 6 weeks post PC-3 CaP cell inoculation, and the fat signal was suppressed using a chemical shift-selective pulse. Subsequently, the MRI data were imported into the image processing software Avizo Standard and stacked into three-dimensional (3D) volumes. Our results demonstrate that MRI, combined with 3D reconstruction, is a feasible and sensitive method to assess tumor growth in a PC-3 orthotopic CaP mouse model and this established monitoring approach is promising for longitudinal observation of CaP xenograft development after anticancer therapy in vivo. Further investigation is needed to validate this protocol in a larger cohort of mice to generate enough statistical power

    A novel magnetic resonance imaging postprocessing technique for the assessment of intervertebral disc degeneration-Correlation with histological grading in a rabbit disc degeneration model.

    Full text link
    Introduction: Estimation of intervertebral disc degeneration on magnetic resonance imaging (MRI) is challenging. Qualitative schemes used in clinical practice correlate poorly with pain and quantitative techniques have not entered widespread clinical use. Methods: As part of a prior study, 25 New Zealand white rabbits underwent annular puncture to induce disc degeneration in 50 noncontiguous lumbar discs. At 16 weeks, the animals underwent multi-echo T2 MRI scanning and were euthanized. The discs were stained and examined histologically. Quantitative T2 relaxation maps were prepared using the nonlinear least squares method. Decay Variance maps were created using a novel technique of aggregating the deviation in the intensity of each echo signal from the expected intensity based on the previous rate of decay. Results: Decay Variance maps showed a clear and well demarcated nucleus pulposus with a consistent rate of decay (low Decay Variance) in healthy discs that showed progressively more variable decay (higher Decay Variance) with increasing degeneration. Decay Variance maps required significantly less time to generate (1.0 ± 0.0 second) compared with traditional T2 relaxometry maps (5 (±0.9) to 1788.9 (±116) seconds). Histology scores correlated strongly with Decay Variance scores (r = 0.82, P < .01) and weakly with T2 signal intensity (r = 0.32, P < .01) and quantitative T2 relaxometry (r = 0.39, P < .01). Decay Variance had superior sensitivity and specificity for the detection of degenerate discs when compared to T2 signal intensity or Quantitative T2 mapping. Conclusion: Our results show that using a multi-echo T2 MRI sequence, Decay Variance can quantitatively assess disc degeneration more accurately and with less image-processing time than quantitative T2 relaxometry in a rabbit disc puncture model. The technique is a viable candidate for quantitative assessment of disc degeneration on MRI scans. Further validation on human subjects is needed

    Ultrasound volume projection image quality selection by ranking from convolutional RankNet.

    Full text link
    Periodic inspection and assessment are important for scoliosis patients. 3D ultrasound imaging has become an important means of scoliosis assessment as it is a real-time, cost-effective and radiation-free imaging technique. With the generation of a 3D ultrasound volume projection spine image using our Scolioscan system, a series of 2D coronal ultrasound images are produced at different depths with different qualities. Selecting a high quality image from these 2D images is the crucial task for further scoliosis measurement. However, adjacent images are similar and difficult to distinguish. To learn the nuances between these images, we propose selecting the best image automatically, based on their quality rankings. Here, the ranking algorithm we use is a pairwise learning-to-ranking network, RankNet. Then, to extract more efficient features of input images and to improve the discriminative ability of the model, we adopt the convolutional neural network as the backbone due to its high power of image exploration. Finally, by inputting the images in pairs into the proposed convolutional RankNet, we can select the best images from each case based on the output ranking orders. The experimental result shows that convolutional RankNet achieves better than 95.5% top-3 accuracy, and we prove that this performance is beyond the experience of a human expert

    Is L5-S1 motion segment different from the rest? A radiographic kinematic assessment of 72 patients with chronic low back pain.

    Full text link
    PURPOSE: The relationship between biomechanical instability and degenerative changes in the lumbar spine in chronic low back pain (CLBP) patients remains controversial. The main objective of this retrospective radiographical study was to evaluate changes in kinematics at different lumbar levels (in particular the L5-S1 level) with progressive grades of disc degeneration and facet joint osteoarthritis in CLBP patients. METHODS: Using standing neutral and dynamic flexion/extension (Fx/Ex) radiographs of the lumbar spine, in vivo segmental kinematics at L1-L2 through L5-S1 were evaluated in 72 consecutive CLBP patients. Disc degeneration was quantified using changes in signal intensity and central disc height on mid-sagittal T2-weighted magnetic resonance (MR) scans. Additionally, the presence or absence of facet joint osteoarthritis was noted on T2-weighted axial MR scans. RESULTS: Disc degeneration and facet joint osteoarthritis occurred independent of each other at the L5-S1 level (p = 0.188), but an association was observed between the two at L4-L5 (p < 0.001) and L3-L4 (p < 0.05) levels. In the absence of facet joint osteoarthritis, the L5-S1 segment showed a greater range of motion (ROM) in Ex (3.3° ± 3.6°) and a smaller ROM in Fx (0.6° ± 4.2°) compared with the upper lumbar levels (p < 0.05), but the differences diminished in the presence of it. In the absence of facet joint osteoarthritis, no change in L5-S1 kinematics was observed with progressive disc degeneration, but in its presence, restabilisation of the L5-S1 segment was observed between mild and severe disc degeneration states. CONCLUSION: The L5-S1 motion segment exhibited unique degenerative and kinematic characteristics compared with the upper lumbar motion segments. Disc degeneration and facet joint osteoarthritis occurred independent of each other at the L5-S1 level, but not at the other lumbar levels. Severe disc degeneration in the presence of facet joint osteoarthritis biomechanically restabilised the L5-S1 motion segment

    Replacing the Nucleus Pulposus for Degenerative Disc Disease and Disc Herniation: Disc Preservation Following Discectomy

    Full text link
    Low back pain is the leading cause of years lived with disability worldwide and thus a significant burden on the economy and healthcare systems. Degenerative changes and/or repetitive abnormal loading in the lumbar spine could lead to structural failures of the intervertebral disc and herniation of the nucleus pulposus, all of which may manifest as chronic back and/or leg pain. Although lumbar discectomy is a clinically beneficial procedure for appropriately selected disc herniation patients, revision discectomy rates range from 2% to 18% within the first decade of the primary discectomy, especially in patients younger than 65 years. Discectomy being a tissue discarding procedure may compromise the biomechanical integrity of the disc and accelerate its degeneration. Nucleus replacement (NR) implants present a promising option to address some of the challenges surrounding lumbar discectomy. An NR implant may be used as an adjunct to discectomy to preserve the biomechanical integrity of the disc and minimize recurrent herniation of the nuclear tissue. Nonetheless, a systematic review of the literature on clinical outcomes for NR implants revealed high rates for endplate remodeling and implant subsidence. A detailed multiscale understanding of the mechanisms of disc herniation and reherniation, closure of the annular defect, and the ability to tailor geometry and material properties for individual patients are needed to develop the next generation of NR implants

    Is Stand-Alone Anterior Lumbar Interbody Fusion a Safe and Efficacious Treatment for Isthmic Spondylolisthesis of L5-S1?

    Full text link
    Study Design: A systematic review. Objective: The objective of this study was to determine the safety and efficacy of stand-alone anterior lumbar interbody fusion (sa-ALIF) for the treatment of symptomatic isthmic spondylolisthesis of L5-S1 by assessing the level of available clinical and radiographic evidence. Methods: A systematic review utilizing Medline, Embase, and Scopus online databases was undertaken. Clinical, radiographic, and adverse outcome data were extracted for the relevant isthmic spondylolisthesis cases with the intention of undertaking a meta-analysis. Results: The database search between January 1980 and December 2015 yielded 23 articles that concerned sa-ALIF for isthmic spondylolisthesis of L5-S1. Only in 9 of the 23 articles data could be extracted specific to sa-ALIF for isthmic spondylolisthesis of L5-S1. There was considerable inconsistency in the standards for reporting outcomes of the surgery due to which meta-analysis could not be undertaken, and hence each article was reviewed. Conclusions: There was insufficient evidence to support the safety and efficacy of sa-ALIF for the treatment of isthmic spondylolisthesis of L5-S1. Although sa-ALIF is widely documented in the literature, there was insufficient evidence to support its use in treating this specific pathology. The unique pathological and anatomical situation that isthmic spondylolisthesis of L5-S1 presents must be recognized and its treatment with sa-ALIF should be well thought out
    corecore