5 research outputs found
RAMSEY FRINGES USING TRANSITIONS IN THE VISIBLE AND 10 µm SPECTRAL REGIONS : EXPERIMENTAL METHODS
A description is given of the experimental system which was used for obtaining Ramsey fringes with an atomic beam for the Ca 657 nm line, and for the system which is being set up to obtain fringes with a large absorption cell for various molecules in the 10 µm region. Details of the cat's eye and segmented retroreflector optical systems are discussed. Results obtained with Ca include fringe widths as small as 1 kHz HWHM, resolution of the recoil splitting, and resolution of second-order Doppler broadening and shift. The experiment at 10 µm is in progress and has already yielded a 1.25 kHz linewidth (HWHM) for the single zone signal with the SF6 molecule
Stability of an injection-locked DFB 1.5 m semiconductor laser
The stability of an injection-locked DFB 1.5 m diode laser is studied systematically. A master diode laser with high spectral purity is used to injection lock a similar diode laser. The spectral purity of the master laser is successfully transmitted to the slave diode laser. A numerical simulation fits the experimental results and gives exact simple interpretations of the behavior of the slave diode laser. Three regimes occur at different injection levels. The relaxation hole appearing on the locking range pattern, for medium and strong injection regimes, is fully explained and leads to a complete explanation of the stability of the slave diode laser. As a consequence, two possible determinations of the Henry factor [1] are presented, with a 5 % precision for one of them.La stabilité d'un laser à semiconducteur DFB à 1,5 m verrouillé par injection est étudiée de façon systématique. Une diode laser maître à faible bruit de fréquence est utilisée pour injecter une diode laser du même type. La pureté spectrale du laser
maître est intégralement transmise à la diode esclave. Une simulation numérique rend compte des résultats expérimentaux et permet d'obtenir une interprétation simple du comportement de la diode esclave. Trois régimes se manifestent à plusieurs niveaux d'injection. Le trou de relaxation apparaissant dans la plage d'accrochage, dans les cas d'injection moyenne et forte, s'interprète totalement et permet d'expliquer complètement la stabilité de la diode laser esclave. Comme conséquence, deux déterminations du facteur de Henry [1] sont exposées, l'une d'elles avec une précision de 5 %
Première observation de la structure hyperfine magnétique dans le spectre infrarouge de l'ammoniac
We give the first experimental observation of a magnetic hyperfine structure in the infrared spectrum of ammonia through saturation spectroscopy. The ν 2 as R(2,0) transition of 15NH3 in close coincidence with the 10R(42) CO2 laser line has been recorded with a 2 kHz halfwidth, which was limited by the molecular transit time across the laser beam. The observed spectrum appeared to be very sensitive to an external magnetic field so that the earth field has to be compensated.Nous présentons la première observation expérimentale, par spectroscopie de saturation, de la structure hyperfine magnétique dans le spectre infrarouge de l'ammoniac. Le spectre de la transition as R(2,0) de la bande ν 2 de 15NH3, en quasi-coïncidence avec la raie 10R(42) du laser à CO2, a été enregistré avec une demi-largeur de raie de 2 kHz, limitée par le temps de vol des molécules à travers le faisceau laser. Ce spectre s'est avéré très sensible à un champ magnétique extérieur de sorte que le champ terrestre a dû être compensé
A NEW ABSOLUTE FREQUENCY REFERENCE GRID IN THE 28 THz RANGE
A new grid of frequency markers based on 12C16O2 lasers locked to OsO4 saturation peaks is presented. This grid extends from the P(22) to the R(26) CO2 laser lines of the 10.4 µm band and covers 1.12 THz with a 1 kHz accuracy for all the measured frequency differences. This set of measurements includes the 192 OsO4 line, which is in close coincidence with the P(14) 12C16O2 line and whose frequency has been connected to the Cesium primary standard with the same accuracy