286 research outputs found

    An X-ray Polarimeter for HXMT Mission

    Get PDF
    The development of micropixel gas detectors, capable to image tracks produced in a gas by photoelectrons, makes possible to perform polarimetry of X-ray celestial sources in the focus of grazing incidence X-ray telescopes. HXMT is a mission by the Chinese Space Agency aimed to survey the Hard X-ray Sky with Phoswich detectors, by exploitation of the direct demodulation technique. Since a fraction of the HXMT time will be spent on dedicated pointing of particular sources, it could host, with moderate additional resources a pair of X-ray telescopes, each with a photoelectric X-ray polarimeter in the focal plane. We present the design of the telescopes and the focal plane instrumentation and discuss the performance of this instrument to detect the degree and angle of linear polarization of some representative sources. Notwithstanding the limited resources the proposed instrument can represent a breakthrough in X-ray Polarimetry.Comment: 10 pages, 9 figure

    Real-Time Laryngeal Cancer Boundaries Delineation on White Light and Narrow-Band Imaging Laryngoscopy with Deep Learning

    Get PDF
    Objective: To investigate the potential of deep learning for automatically delineating (segmenting) laryngeal cancer superficial extent on endoscopic images and videos. Methods: A retrospective study was conducted extracting and annotating white light (WL) and Narrow-Band Imaging (NBI) frames to train a segmentation model (SegMENT-Plus). Two external datasets were used for validation. The model's performances were compared with those of two otolaryngology residents. In addition, the model was tested on real intraoperative laryngoscopy videos. Results: A total of 3933 images of laryngeal cancer from 557 patients were used. The model achieved the following median values (interquartile range): Dice Similarity Coefficient (DSC) = 0.83 (0.70-0.90), Intersection over Union (IoU) = 0.83 (0.73-0.90), Accuracy = 0.97 (0.95-0.99), Inference Speed = 25.6 (25.1-26.1) frames per second. The external testing cohorts comprised 156 and 200 images. SegMENT-Plus performed similarly on all three datasets for DSC (p = 0.05) and IoU (p = 0.07). No significant differences were noticed when separately analyzing WL and NBI test images on DSC (p = 0.06) and IoU (p = 0.78) and when analyzing the model versus the two residents on DSC (p = 0.06) and IoU (Senior vs. SegMENT-Plus, p = 0.13; Junior vs. SegMENT-Plus, p = 1.00). The model was then tested on real intraoperative laryngoscopy videos. Conclusion: SegMENT-Plus can accurately delineate laryngeal cancer boundaries in endoscopic images, with performances equal to those of two otolaryngology residents. The results on the two external datasets demonstrate excellent generalization capabilities. The computation speed of the model allowed its application on videolaryngoscopies simulating real-time use. Clinical trials are needed to evaluate the role of this technology in surgical practice and resection margin improvement. Level of evidence: III Laryngoscope, 2024

    An X-ray polarimeter for hard X-ray optics

    Get PDF
    Development of multi-layer optics makes feasible the use of X-ray telescope at energy up to 60-80 keV: in this paper we discuss the extension of photoelectric polarimeter based on Micro Pattern Gas Chamber to high energy X-rays. We calculated the sensitivity with Neon and Argon based mixtures at high pressure with thick absorption gap: placing the MPGC at focus of a next generation multi-layer optics, galatic and extragalactic X-ray polarimetry can be done up till 30 keV.Comment: 12 pages, 7 figure

    A photoelectric polarimeter for XEUS: a new window in x-ray sky

    Get PDF
    XEUS is a large area telescope aiming to rise X-ray Astronomy to the level of Optical Astronomy in terms of collecting areas. It will be based on two satellites, locked on a formation flight, one with the optics, one with the focal plane. The present design of the focal plane foresees, as an auxiliary instrument, the inclusion of a Polarimeter based on a Micropattern Chamber. We show how such a device is capable to solve open problems on many classes of High Energy Astrophysics objects and to use X-ray sources as a laboratory for a substantial progress on Fundamental Physics.Comment: 12 pages, 7 figure

    POLARIX: a small mission of x-ray polarimetry

    Get PDF
    X-Ray Polarimetry can be now performed by using a Micro Pattern Gas Chamber in the focus of a telescope. It requires large area optics for most important scientific targets. But since the technique is additive a dedicated mission with a cluster of small telescopes can perform many important measurements and bridge the 40 year gap between OSO-8 data and future big telescopes such as XEUS. POLARIX has been conceived as such a pathfinder. It is a Small Satellite based on the optics of JET-X. Two telescopes are available in flight configuration and three more can be easily produced starting from the available superpolished mandrels. We show the capabilities of such a cluster of telescopes each equipped with a focal plane photoelectric polarimeter and discuss a few alternative solutions.Comment: 9 pages, 5 figure

    Influenza vaccination coverage among medical residents: An Italian multicenter survey

    Get PDF
    Although influenza vaccination is recognized to be safe and effective, recent studies have confirmed that immunization coverage among health care workers remain generally low, especially among medical residents (MRs). Aim of the present multicenter study was to investigate attitudes and determinants associated with acceptance of influenza vaccination among Italian MRs. A survey was performed in 2012 on MRs attending post-graduate schools of 18 Italian Universities. Each participant was interviewed via an anonymous, self-administered, web-based questionnaire including questions on attitudes regarding influenza vaccination. A total of 2506 MRs were recruited in the survey and 299 (11.9%) of these stated they had accepted influenza vaccination in 2011-2012 season. Vaccinated MRs were older (P = 0.006), working in clinical settings (P = 0.048), and vaccinated in the 2 previous seasons (P < 0.001 in both seasons). Moreover, MRs who had recommended influenza vaccination to their patients were significantly more compliant with influenza vaccination uptake in 2011-2012 season (P < 0.001). "To avoid spreading influenza among patients" was recognized as the main reason for accepting vaccination by less than 15% of vaccinated MRs. Italian MRs seem to have a very low compliance with influenza vaccination and they seem to accept influenza vaccination as a habit that is unrelated to professional and ethical responsibility. Otherwise, residents who refuse vaccination in the previous seasons usually maintain their behaviors. Promoting correct attitudes and good practice in order to improve the influenza immunization rates of MRs could represent a decisive goal for increasing immunization coverage among health care workers of the future. © 2014 Landes Bioscience

    A Precision Measurement of the Lambda_c Baryon Mass

    Full text link
    The Λc+\Lambda_c^+ baryon mass is measured using Λc+ΛKS0K+\Lambda_c^+\to\Lambda K^0_S K^+ and Λc+Σ0KS0K+\Lambda_c^+\to\Sigma^0 K^0_S K^+ decays reconstructed in 232 fb1^{-1} of data collected with the BaBar detector at the PEP-II asymmetric-energy e+ee^+e^- storage ring. The Λc+\Lambda_c^+ mass is measured to be 2286.46±0.14MeV/c22286.46\pm0.14\mathrm{MeV}/c^2. The dominant systematic uncertainties arise from the amount of material in the tracking volume and from the magnetic field strength.Comment: 14 pages, 8 postscript figures, submitted to Phys. Rev.

    Multi-messenger observations of a binary neutron star merger

    Get PDF
    On 2017 August 17 a binary neutron star coalescence candidate (later designated GW170817) with merger time 12:41:04 UTC was observed through gravitational waves by the Advanced LIGO and Advanced Virgo detectors. The Fermi Gamma-ray Burst Monitor independently detected a gamma-ray burst (GRB 170817A) with a time delay of ~1.7 s with respect to the merger time. From the gravitational-wave signal, the source was initially localized to a sky region of 31 deg2 at a luminosity distance of 40+8-8 Mpc and with component masses consistent with neutron stars. The component masses were later measured to be in the range 0.86 to 2.26 Mo. An extensive observing campaign was launched across the electromagnetic spectrum leading to the discovery of a bright optical transient (SSS17a, now with the IAU identification of AT 2017gfo) in NGC 4993 (at ~40 Mpc) less than 11 hours after the merger by the One- Meter, Two Hemisphere (1M2H) team using the 1 m Swope Telescope. The optical transient was independently detected by multiple teams within an hour. Subsequent observations targeted the object and its environment. Early ultraviolet observations revealed a blue transient that faded within 48 hours. Optical and infrared observations showed a redward evolution over ~10 days. Following early non-detections, X-ray and radio emission were discovered at the transient’s position ~9 and ~16 days, respectively, after the merger. Both the X-ray and radio emission likely arise from a physical process that is distinct from the one that generates the UV/optical/near-infrared emission. No ultra-high-energy gamma-rays and no neutrino candidates consistent with the source were found in follow-up searches. These observations support the hypothesis that GW170817 was produced by the merger of two neutron stars in NGC4993 followed by a short gamma-ray burst (GRB 170817A) and a kilonova/macronova powered by the radioactive decay of r-process nuclei synthesized in the ejecta

    Studies of η\eta and η\eta' production in pppp and ppPb collisions

    Full text link
    The production of η\eta and η\eta' mesons is studied in proton-proton and proton-lead collisions collected with the LHCb detector. Proton-proton collisions are studied at center-of-mass energies of 5.025.02 and 13 TeV13~{\rm TeV}, and proton-lead collisions are studied at a center-of-mass energy per nucleon of 8.16 TeV8.16~{\rm TeV}. The studies are performed in center-of-mass rapidity regions 2.5<yc.m.<3.52.5<y_{\rm c.m.}<3.5 (forward rapidity) and 4.0<yc.m.<3.0-4.0<y_{\rm c.m.}<-3.0 (backward rapidity) defined relative to the proton beam direction. The η\eta and η\eta' production cross sections are measured differentially as a function of transverse momentum for 1.5<pT<10 GeV1.5<p_{\rm T}<10~{\rm GeV} and 3<pT<10 GeV3<p_{\rm T}<10~{\rm GeV}, respectively. The differential cross sections are used to calculate nuclear modification factors. The nuclear modification factors for η\eta and η\eta' mesons agree at both forward and backward rapidity, showing no significant evidence of mass dependence. The differential cross sections of η\eta mesons are also used to calculate η/π0\eta/\pi^0 cross section ratios, which show evidence of a deviation from the world average. These studies offer new constraints on mass-dependent nuclear effects in heavy-ion collisions, as well as η\eta and η\eta' meson fragmentation.Comment: All figures and tables, along with machine-readable versions and any supplementary material and additional information, are available at https://lhcbproject.web.cern.ch/Publications/p/LHCb-PAPER-2023-030.html (LHCb public pages
    corecore