4 research outputs found

    Pullout performance comparison of pedicle screws based on cement application and design parameters

    No full text
    Pedicle screws are the main fixation devices for certain surgeries. Pedicle screw loosening is a common problem especially for osteoporotic incidents. Cannulated screws with cement augmentation are widely used for that kind of cases. Dual lead dual cored pedicle screw has already given promising pullout values without augmentation. This study concentrates on the usage of dual lead dual core with cement augmentation as an alternative to cannulated and standard pedicle screws with cement augmentation. Five groups (dual lead dual core, normal pedicle screw and cannulated pedicle screw with augmentation, normal pedicle screw, dual lead dual cored pedicle screw) were designed for this study. Healthy bovine vertebrae and synthetic polyurethane foams (grade 20) were used as embedding test medium. Test samples were prepared in accordance with surgical guidelines and ASTM F543 standard testing protocols. Pullout tests were conducted with Instron 3300 testing frame. Load versus displacement values were recorded and maximum pullout loads were stated. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation exhibited the highest pullout values, while dual lead dual cored pedicle screw demonstrated similar pullout strength as cannulated pedicle screw and normal pedicle screw with poly-methyl methacrylate augmentation. The dual lead dual cored pedicle screw with poly-methyl methacrylate augmentation can be used for osteoporotic and/or severe osteoporotic patients according to its promising results on animal cadaver and synthetic foams.The authors of this study acknowledge to Turkish Science Foundation (TUBITAK) for the financial support for the study with project number of 113S101 and acknowledge to Osimplant Medical Devices for the preparation of the test samples

    Acoustic Parameters for Optimal Ultrasound-Triggered Release from Novel Spinal Hardware Devices.

    Get PDF
    Post-operative infection is a catastrophic complication of spinal fusion surgery, with rates as high as 10%, and existing preventative measures (i.e., peri-operative antibiotics) are only partially successful. To combat this clinical problem, we have designed a drug delivery system around polyether ether ketone clips to be used for prophylactic post-surgical release of antibiotics upon application of ultrasound. The overall hypothesis is that antimicrobial release from this system will aggressively combat post-surgical bacterial survival. This study investigated a set of acoustic parameters optimized for in vitro ultrasound-triggered coating rupture and subsequent release of encapsulated prophylactic antibiotics. We determined that a transducer frequency of 1.7 MHz produced the most consistent burst release and that, at this frequency, a pulse repetition frequency of 6.4 kHz and acoustic output power of 100% (3.41 MPa) produced the greatest release, representing an important proof of principle and the basis for continued development of this novel drug delivery system
    corecore