46 research outputs found

    Evolution of Gaussian wave packets in capillary jets

    Get PDF
    A temporal analysis of the evolution of Gaussian wave packets in cylindrical capillary jets is presented through both a linear two-mode formulation and a one-dimensional nonlinear numerical scheme. These analyses are normally applicable to arbitrary initial conditions but our study focuses on pure-impulsive ones. Linear and nonlinear findings give consistent results in the stages for which the linear theory is valid. The inverse Fourier transforms representing the formal linear solution for the jet shape is both numerically evaluated and approximated by closed formulas. After a transient, these formulas predict an almost Gaussian-shape deformation with (i) a progressive drift of the carrier wave number to that given by the maximum of the Rayleigh dispersion relation, (ii) a progressive increase of its bell width, and (iii) a quasi-exponential growth of its amplitude. These parameters agree with those extracted from the fittings of Gaussian wave packets to the numerical simulations. Experimental results are also reported on near-Gaussian pulses perturbing the exit velocity of a 2 mm diameter water jet. The possibility of controlling the breakup location along the jet and other features, such as pinch-off simultaneity, are demonstrated

    Cut-offs and response criteria for the Hospital Universitario la Princesa Index (HUPI) and their comparison to widely-used indices of disease activity in rheumatoid arthritis

    Get PDF
    Objective To estimate cut-off points and to establish response criteria for the Hospital Universitario La Princesa Index (HUPI) in patients with chronic polyarthritis. Methods Two cohorts, one of early arthritis (Princesa Early Arthritis Register Longitudinal PEARL] study) and other of long-term rheumatoid arthritis (Estudio de la Morbilidad y Expresi贸n Cl铆nica de la Artritis Reumatoide EMECAR]) including altogether 1200 patients were used to determine cut-off values for remission, and for low, moderate and high activity through receiver operating curve (ROC) analysis. The areas under ROC (AUC) were compared to those of validated indexes (SDAI, CDAI, DAS28). ROC analysis was also applied to establish minimal and relevant clinical improvement for HUPI. Results The best cut-off points for HUPI are 2, 5 and 9, classifying RA activity as remission if =2, low disease activity if >2 and =5), moderate if >5 and <9 and high if =9. HUPI''s AUC to discriminate between low-moderate activity was 0.909 and between moderate-high activity 0.887. DAS28''s AUCs were 0.887 and 0.846, respectively; both indices had higher accuracy than SDAI (AUCs: 0.832 and 0.756) and CDAI (AUCs: 0.789 and 0.728). HUPI discriminates remission better than DAS28-ESR in early arthritis, but similarly to SDAI. The HUPI cut-off for minimal clinical improvement was established at 2 and for relevant clinical improvement at 4. Response criteria were established based on these cut-off values. Conclusions The cut-offs proposed for HUPI perform adequately in patients with either early or long term arthritis

    TOXOPLASMOSIS IN MEXICO: EPIDEMIOLOGICAL SITUATION IN HUMANS AND ANIMALS

    Full text link

    Design, development, and evaluation of a simple blackbody radiative source.

    No full text
    This paper presents a simple design and the testing of a blackbody prototype. The physical properties and geometry of the cavity produce a radiator or blackbody with an emissivity greater than 0.99. The prototype has the advantages of having a traditional spherical cavity made of alumina refractory cement and a radiative emission very close to that of an ideal blackbody. The prototype can be used as a calibration standard for other radiation measuring instruments or sensors. Experimental measurements of radiant flux of the prototype measured with a calibrated infrared radiometer and a wide spectrum radiometer are also presented. The prototype is easy to construct and the material required are available to most research centers, laboratories, industries, and universities

    Design, development, and evaluation of a simple blackbody radiative source.

    No full text
    This paper presents a simple design and the testing of a blackbody prototype. The physical properties and geometry of the cavity produce a radiator or blackbody with an emissivity greater than 0.99. The prototype has the advantages of having a traditional spherical cavity made of alumina refractory cement and a radiative emission very close to that of an ideal blackbody. The prototype can be used as a calibration standard for other radiation measuring instruments or sensors. Experimental measurements of radiant flux of the prototype measured with a calibrated infrared radiometer and a wide spectrum radiometer are also presented. The prototype is easy to construct and the material required are available to most research centers, laboratories, industries, and universities

    Design, development, and evaluation of a simple blackbody radiative source

    No full text
    This paper presents a simple design and the testing of a blackbody prototype. The physical properties and geometry of the cavity produce a radiator or blackbody with an emissivity greater than 0.99. The prototype has the advantages of having a traditional spherical cavity made of alumina refractory cement and a radiative emission very close to that of an ideal blackbody. The prototype can be used as a calibration standard for other radiation measuring instruments or sensors. Experimental measurements of radiant flux of the prototype measured with a calibrated infrared radiometer and a wide spectrum radiometer are also presented. The prototype is easy to construct and the material required are available to most research centers, laboratories, industries, and universities. 漏 2010 American Institute of Physics

    Critical angle laser refractometer

    No full text
    A simple laser refractometer based on the detection of the critical angle for liquids is presented. The calibrated refractometer presents up to 0.000 11 of uncertainty when the refractive index is in the range between 1.300 00 and 1.340 00. The experimental setup is easy to construct and the material needed is available at most optics laboratories. The calibration method is simple and can be used in other devices. The refractive index measurements in aqueous solutions of sodium chloride were carried out to test the device and a linear dependence between the refractive index and the salt concentration was found. 漏 2006 American Institute of Physics

    Development and evaluation of an alternative method for processing elastic-lidar return signals

    No full text
    A method for interpreting elastic-lidar return signals in heavily-polluted atmospheres is presented. It is based on an equation derived directly from the classic lidar equation, which highlights gradients of the atmospheric backscattering properties along the laser optical path. The method is evaluated by comparing its results with those obtained with the differential absorption technique. The results were obtained from locating and ranging measurements in pollutant plumes and contaminated environments around central M茅xico. 漏 World Scientific Publishing Company
    corecore