First measurement of low intensity fast neutron background from rock at the Boulby Underground Laboratory
A technique to measure low intensity fast neutron flux has been developed.
The design, calibrations, procedure for data analysis and interpretation of the
results are discussed in detail. The technique has been applied to measure the
neutron background from rock at the Boulby Underground Laboratory, a site used
for dark matter and other experiments, requiring shielding from cosmic ray
muons. The experiment was performed using a liquid scintillation detector. A
6.1 litre volume stainless steel cell was filled with an in-house made liquid
scintillator loaded with Gd to enhance neutron capture. A two-pulse signature
(proton recoils followed by gammas from neutron capture) was used to identify
the neutron events from much larger gamma background from PMTs. Suppression of
gammas from the rock was achieved by surrounding the detector with high-purity
lead and copper. Calibrations of the detector were performed with various gamma
and neutron sources. Special care was taken to eliminate PMT afterpulses and
correlated background events from the delayed coincidences of two pulses in the
Bi-Po decay chain. A four month run revealed a neutron-induced event rate of
1.84 +- 0.65 (stat.) events/day. Monte Carlo simulations based on the GEANT4
toolkit were carried out to estimate the efficiency of the detector and the
energy spectra of the expected proton recoils. From comparison of the measured
rate with Monte Carlo simulations the flux of fast neutrons from rock was
estimated as (1.72 +- 0.61 (stat.) +- 0.38 (syst.))*10^(-6) cm^(-2) s^(-1)
above 0.5 MeV.Comment: 37 pages, 24 figures, to be published in Astroparticle Physic
Reduction of Coincident Photomultiplier Noise Relevant to Astroparticle Physics Experiment
In low background and low threshold particle astrophysics experiments using
observation of Cherenkov or scintillation light it is common to use pairs or
arrays of photomultipliers operated in coincidence. In such circumstances, for
instance in dark matter and neutrino experiments, unexpected PMT noise events
have been observed, probably arising from generation of light from one PMT
being detected by one or more other PMTs. We describe here experimental
investigation of such coincident noise events and development of new techniques
to remove them using novel pulse shape discrimination procedures. When applied
to data from a low background NaI detector with facing PMTs the new procedures
are found to improve noise rejection by a factor of 20 over conventional
techniques, with significantly reduced loss of signal events.Comment: Submitted to NIM
The Higher Derivative Expansion of the Effective Action by the String-Inspired Method, Part I
The higher derivative expansion of the one-loop effective action for an
external scalar potential is calculated to order O(T**7), using the
string-inspired Bern-Kosower method in the first quantized path integral
formulation. Comparisons are made with standard heat kernel calculations and
with the corresponding Feynman diagrammatic calculation in order to show the
efficiency of the present method.Comment: 13 pages, Plain TEX, 1 figure may be obtained from the authors,
HD-THEP-93-4
Recommended from our members
A new high-gradient correction quadrupole for the Fermilab luminosity upgrade
Special superconducting correction quadrupoles are needed for the luminosity upgrade of the Fermilab Tevatron Collider. These correctors are part of the low-beta system for the interaction regions at B/phi/ and D/phi/. The requirements are high gradient and low current. A quadrupole has been designed that meets the operating gradient of 0.63 T/cm at 1086 A. The one-layer quadrupole is wound with a cable consisting of five individually insulated rectangular strands. The five strands are overwrapped with Kapton and epoxy impregnated glass tape. The winding, curing and collaring of the magnet is accomplished in the same manner as Tevatron-like magnets using Rutherford style cable. Once the magnet is complete the five strands are connected in series. A prototype quadrupole has been assembled and tested. The magnet reached a plateau current of 1560 A corresponding to a gradient of 0.91 T/cm without training. The measured field harmonics are substantially better than required. 8 refs., 6 figs., 4 tabs
Simulations of neutron background in a time projection chamber relevant to dark matter searches
Presented here are results of simulations of neutron background performed for
a time projection chamber acting as a particle dark matter detector in an
underground laboratory. The investigated background includes neutrons from rock
and detector components, generated via spontaneous fission and (alpha, n)
reactions, as well as those due to cosmic-ray muons. Neutrons were propagated
to the sensitive volume of the detector and the nuclear recoil spectra were
calculated. Methods of neutron background suppression were also examined and
limitations to the sensitivity of a gaseous dark matter detector are discussed.
Results indicate that neutrons should not limit sensitivity to WIMP-nucleon
interactions down to a level of (1 - 3) x 10^{-8} pb in a 10 kg detector.Comment: 27 pages (total, including 3 tables and 11 figures). Accepted for
publication in Nuclear Instruments and Methods in Physics Research - Section
Neutron background in large-scale xenon detectors for dark matter searches
Simulations of the neutron background for future large-scale particle dark
matter detectors are presented. Neutrons were generated in rock and detector
elements via spontaneous fission and (alpha,n) reactions, and by cosmic-ray
muons. The simulation techniques and results are discussed in the context of
the expected sensitivity of a generic liquid xenon dark matter detector.
Methods of neutron background suppression are investigated. A sensitivity of
pb to WIMP-nucleon interactions can be achieved by a
tonne-scale detector.Comment: 35 pages, 13 figures, 2 tables, accepted for publication in
Astroparticle Physic
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
The ZEPLIN II dark matter detector: data acquisition system and data reduction
ZEPLIN-II is a two-phase (liquid/gas) xenon dark matter detector searching
for WIMP-nucleon interactions. In this paper we describe the data acquisition
system used to record the data from ZEPLIN-II and the reduction procedures
which parameterise the data for subsequent analysis.Comment: 11 pages, 10 figure
Electronic cigarettes: A position statement from the Thoracic Society of Australia and New Zealand*
The TSANZ develops position statements where insufficient data exist to write formal clinical guidelines. In 2018, the TSANZ addressed the question of potential benefits and health impacts of electronic cigarettes (EC). The working party included groups focused on health impacts, smoking cessation, youth issues and priority populations. The 2018 report on the Public Health Consequences of E-Cigarettes from the United States NASEM was accepted as reflective of evidence to mid-2017. A search for papers subsequently published in peer-reviewed journals was conducted in August 2018. A small number of robust and important papers published until March 2019 were also identified and included. Groups identified studies that extended, modified or contradicted the NASEM report. A total of 3793 papers were identified and reviewed, with summaries and draft position statements developed and presented to TSANZ membership in April 2019. After feedback from members and external reviewers, a collection of position statements was finalized in December 2019. EC have adverse lung effects and harmful effects of long-term use are unknown. EC are unsuitable consumer products for recreational use, part-substitution for smoking or long-term exclusive use by former smokers. Smokers who require support to quit smoking should be directed towards approved medication in conjunction with behavioural support as having the strongest evidence for efficacy and safety. No specific EC product can be recommended as effective and safe for smoking cessation. Smoking cessation claims in relation to EC should be assessed by established regulators
Patient blood management in Europe
Preoperative anaemia is common in patients undergoing orthopaedic and other major surgery. Anaemia is associated with increased risks of postoperative mortality and morbidity, infectious complications, prolonged hospitalization, and a greater likelihood of allogeneic red blood cell (RBC) transfusion. Evidence of the clinical and economic disadvantages of RBC transfusion in treating perioperative anaemia has prompted recommendations for its restriction and a growing interest in approaches that rely on patients' own (rather than donor) blood. These approaches are collectively termed ‘patient blood management’ (PBM). PBM involves the use of multidisciplinary, multimodal, individualized strategies to minimize RBC transfusion with the ultimate goal of improving patient outcomes. PBM relies on approaches (pillars) that detect and treat perioperative anaemia and reduce surgical blood loss and perioperative coagulopathy to harness and optimize physiological tolerance of anaemia. After the recent resolution 63.12 of the World Health Assembly, the implementation of PBM is encouraged in all WHO member states. This new standard of care is now established in some centres in the USA and Austria, in Western Australia, and nationally in the Netherlands. However, there is a pressing need for European healthcare providers to integrate PBM strategies into routine care for patients undergoing orthopaedic and other types of surgery in order to reduce the use of unnecessary transfusions and improve the quality of care. After reviewing current PBM practices in Europe, this article offers recommendations supporting its wider implementation, focusing on anaemia management, the first of the three pillars of PBM
- …