18 research outputs found

    Influence of Sex-Based Differences in Cardiac Phenotype on Atrial Fibrillation Recurrence in Patients Undergoing Pulmonary Vein Isolation

    Get PDF
    BackgroundPulmonary vein isolation (PVI) is a commonly engaged therapy for symptomatic atrial fibrillation (AF). Prior studies have documented elevated AF recurrence rates among females vs. males. Sex-specific mechanisms underlying this phenomenon are poorly understood. This prospective cohort study aimed to evaluate the sex-based differences in cardiac phenotype and their influence on (AF) recurrence following first-time PVI.MethodsA total of 204 consecutive patients referred for first-time PVI and 101 healthy subjects were prospectively studied by cardiovascular magnetic resonance (CMR) imaging. Multi-chamber volumetric and functional measures were assessed by sex-corrected Z-score analyses vs. healthy subjects. Patients were followed for a median of 2.6 years for the primary outcome of clinical AF recurrence. Multivariable analyses adjusting for age and comorbidities were performed to identify independent predictors of AF recurrence.ResultsAF recurrence following first PVI occurred in 41% of males and 59% of females (p = 0.03). Females were older with higher prevalence of hypertension and thyroid disorders. Z-score-based analyses revealed significantly reduced ventricular volumes, greater left atrial (LA) volumes, and reduced LA contractility in females vs. males. Multivariable analysis revealed each of LA minimum and pre-systolic volumes and booster EF Z-scores to be independently associated with AF recurrence, providing respective hazard ratios of 1.10, 1.19, and 0.89 (p = 0.001, 0.03, and 0.01).ConclusionAmong patients referred for first time PVI, females were older and demonstrated significantly poorer LA contractile health vs. males, the latter independently associated with AF recurrence. Assessment of LA contractile health may therefore be of value to identify female patients at elevated risk of AF recurrence. Factors influencing female patient referral for PVI at more advanced stages of atrial disease warrant focused investigation

    Three-dimensional thoracic aorta principal strain analysis from routine ECG-gated computerized tomography: feasibility in patients undergoing transcatheter aortic valve replacement

    No full text
    Abstract Background Functional impairment of the aorta is a recognized complication of aortic and aortic valve disease. Aortic strain measurement provides effective quantification of mechanical aortic function, and 3-dimenional (3D) approaches may be desirable for serial evaluation. Computerized tomographic angiography (CTA) is routinely performed for various clinical indications, and offers the unique potential to study 3D aortic deformation. We sought to investigate the feasibility of performing 3D aortic strain analysis in a candidate population of patients undergoing transcatheter aortic valve replacement (TAVR). Methods Twenty-one patients with severe aortic valve stenosis (AS) referred for TAVR underwent ECG-gated CTA and echocardiography. CTA images were analyzed using a 3D feature-tracking based technique to construct a dynamic aortic mesh model to perform peak principal strain amplitude (PPSA) analysis. Segmental strain values were correlated against clinical, hemodynamic and echocardiographic variables. Reproducibility analysis was performed. Results The mean patient age was 81±6 years. Mean left ventricular ejection fraction was 52±14%, aortic valve area (AVA) 0.6±0.3 cm2 and mean AS pressure gradient (MG) 44±11 mmHg. CTA-based 3D PPSA analysis was feasible in all subjects. Mean PPSA values for the global thoracic aorta, ascending aorta, aortic arch and descending aorta segments were 6.5±3.0, 10.2±6.0, 6.1±2.9 and 3.3±1.7%, respectively. 3D PSSA values demonstrated significantly more impairment with measures of worsening AS severity, including AVA and MG for the global thoracic aorta and ascending segment (p<0.001 for all). 3D PSSA was independently associated with AVA by multivariable modelling. Coefficients of variation for intra- and inter-observer variability were 5.8 and 7.2%, respectively. Conclusions Three-dimensional aortic PPSA analysis is clinically feasible from routine ECG-gated CTA. Appropriate reductions in PSSA were identified with increasing AS hemodynamic severity. Expanded study of 3D aortic PSSA for patients with various forms of aortic disease is warranted

    Accuracy and reproducibility of semi-automated late gadolinium enhancement quantification techniques in patients with hypertrophic cardiomyopathy

    No full text
    Abstract Background The presence and extent of late gadolinium enhancement (LGE) has been associated with adverse events in patients with hypertrophic cardiomyopathy (HCM). Signal intensity (SI) threshold techniques are routinely employed for quantification; Full-Width at Half-Maximum (FWHM) techniques are suggested to provide greater reproducibility than Signal Threshold versus Reference Mean (STRM) techniques, however the accuracy of these approaches versus the manual assignment of optimal SI thresholds has not been studied. In this study, we compared all known semi-automated LGE quantification techniques for accuracy and reproducibility among patients with HCM. Methods Seventy-six HCM patients (51 male, age 54 ±13 years) were studied. Total LGE volume was quantified using 7 semi-automated techniques and compared to expert manual adjustment of the SI threshold to achieve optimal segmentation. Techniques tested included STRM based thresholds of >2, 3, 4, 5 and 6 SD above mean SI of reference myocardium, the FWHM technique, and the Otsu-auto-threshold (OAT) technique. The SI threshold chosen by each technique was recorded for all slices. Bland-Altman analysis and intra-class correlation coefficients (ICC) were reported for each semi-automated technique versus expert, manually adjusted LGE segmentation. Intra- and inter-observer reproducibility assessments were also performed. Results Fifty-two of 76 (68%) patients showed LGE on a total of 202 slices. For accuracy, the STRM >3SD technique showed the greatest agreement with manual segmentation (ICC =0.97, mean difference and 95% limits of agreement =1.6 ± 10.7 g) while STRM >6SD, >5SD, 4SD and FWHM techniques systematically underestimated total LGE volume. Slice based analysis of selected SI thresholds similarly showed the STRM >3SD threshold to most closely approximate manually adjusted SI thresholds (ICC =0.88). For reproducibility, the intra- and inter-observer reproducibility of the >3SD threshold demonstrated an acceptable mean difference and 95% limits of agreement of -0.5 ± 6.8 g and -0.9 ± 5.6 g, respectively. Conclusions FWHM segmentation provides superior reproducibility, however systematically underestimates total LGE volume compared to manual segmentation in patients with HCM. The STRM >3SD technique provides the greatest accuracy while retaining acceptable reproducibility and may therefore be a preferred approach for LGE quantification in this population
    corecore