14 research outputs found

    Caseous calcification of the mitral annulus with mitral regurgitation and impairment of functional capacity: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Mitral annular calcification is a common echocardiographic finding, especially in the elderly. Caseous calcification of the mitral annulus, however, is a relatively rare variant, having an echocardiographic prevalence of 0.6% in patients with mitral annular calcification. Caseous calcification needs to be differentiated from infected mitral annular calcification, mitral annular abscess and tumours. It is not malignant, and medical therapy with clinical follow-up is the therapeutic option. Surgery should be reserved for co-existent mitral valve dysfunction.</p> <p>Case presentation</p> <p>We report the case of a 69-year-old woman, in whom caseous calcification of the mitral annulus was found at transthoracic echocardiography. Cardiac surgery was performed because of significant mitral regurgitation and impairment of functional capacity.</p> <p>Conclusion</p> <p>Caseous calcification of the mitral annulus needs to be considered and confirmed by transthoracic echocardiography since there is potential for diagnostic confusion or misdiagnosis. This lesion appears to have a benign prognosis but, when associated with mitral valve dysfunction, cardiac surgery appears to be the best therapeutic option.</p

    An isolated anterior mitral leaflet cleft: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>The anterior mitral leaflet cleft is an unusual congenital lesion most often encountered in association with other congenital heart defects. The isolated anterior leaflet cleft is quite a rare anomaly and is usually cause of mitral valve regurgitation. The importance of the lesion is that it is often correctable. When feasible, cleft suture and, eventually, annuloplasty are preferable to valve replacement. Echocardiography is the first choice technique in the evaluation of mitral valve disease, providing useful information about valve anatomy and hemodynamic parameters.</p> <p>Case presentation</p> <p>We present a case of an isolated anterior mitral leaflet cleft producing moderate-severe mitral regurgitation correctly identified by echocardiography and successfully surgically corrected.</p> <p>Conclusion</p> <p>Isolated cleft is a rare aberration, that has to be known in order to be diagnosed. Transthoracic and transesophageal echocardiography is the most useful non invasive technique for cleft diagnosis and to indicate the right surgical correction.</p

    Feasibility, safety and tolerability of accelerated dobutamine stress echocardiography

    Get PDF
    A continuous infusion of a single high dose of dobutamine has been, recently, suggested as a simple and effective protocol of stress echocardiography. The present study assesses the feasibility, safety, and tolerability of an accelerated dobutamine stress protocol performed in patients with suspected or known coronary artery disease. Two hundred sixty five consecutive patients underwent accelerated dobutamine stress echocardiography: the dobutamine was administered at a constant dose of 50 μg/kg/min for up to 10 minutes. The mean weight-adjusted cumulative dose of dobutamine used was 330 ± 105.24 μg/kg. Total duration of dobutamine infusion was 6.6 ± 2.1 min. Heart rate rose from 69.9 ± 12.1 to 123.1 ± 22.1 beats/min at peak with a concomitant change in systolic blood pressure (127.6 ± 18.1 vs. 167.6 ± 45.0 mmHg). Dobutamine administration produced a rapid increase in heart rate (9.4 ± 5.9 beats/min2). The side effects were similar to those described with the standard protocol; the most common were frequent premature ventricular complexes (21.5%), frequent premature atrial complexes (1.5%) and non sustained ventricular tachycardia (1.5%); among non cardiac symptoms the most frequent were nausea (3.4%), headache (1.1%) and symptomatic hypotension (1.1%). No major side effects were observed during the test. Our data demonstrate that a continous infusion of a single high dose of dobutamine is a safe and well tolerated method of performing stress echocardiography in patients with suspected or known coronary artery disease. This new protocol requires the administration of lower cumulative dobutamine dose than standard protocol and results in a significant reduction in test time

    Evaluation of 17-mm St. Jude Medical Regent prosthetic aortic heart valves by rest and dobutamine stress echocardiography

    Get PDF
    BACKGROUND: The prosthesis used for aortic valve replacement in patients with small aortic root can be too small in relation to body size, thus showing high transvalvular gradients at rest and/or under stress conditions. This study was carried out to evaluate rest and Dobutamine stress echocardiography (DSE) hemodynamic response of 17-mm St. Jude Medical Regent (SJMR-17 mm) in relatively aged patients at mean 24 months follow-up. METHODS AND RESULTS: The study population consisted of 19 patients (2 men, 17 women, mean age 69.2 ± 7.3 years). All patients underwent rest Doppler echocardiography before and after surgery and basal and DSE at follow up (infused at rate of 5 micrg/Kg/min and increased by 5 microg/Kg/min at 5 min intervals up to 40 microg/Kg/min). The following parameters were evaluated at rest and/or under DSE: heart rate (HR), ejection fraction (EF), cardiac output (CO), peak and mean velocity and pressure gradients (MxV, MnV, MxPG, MnPG), effective orifice area (EOA), indexed EOA (EOAi), left ventricular mass (LVM), indexed LVM (LVMi), Velocity Time Integral at left ventricular outflow tract (VTI LVOT) and transvalvular (Aortic VTI), Doppler velocity index (DVI). At rest MxPG and MnPG were 29.2 ± 7.1 and 16.6 ± 5.8mmHg, respectively; EOA and EOAi resulted 1.14 ± 0.3 cm(2) and 0.76 ± 0.2 cm(2)/m(2); DVI was normal (0.50 ± 0.1). At follow-up LVM and LVMi decreased significantly from pre-operative value of 258 ± 43g and 157.4 ± 27.7g/m(2) to 191 ± 23.8g and 114.5 ± 10.6g/m(2), respectively. DSE increased significantly HR, CO, EF, MxGP (up to 83.4 ± 2 1.9mmHg), MnPG (up to 43.2 ± 12.7mmHg). EOA, EOAi, DVI increased insignificantly (from baseline up to 1.2 ± 0.4 cm(2), 0.75 ± 0.3cm(2)/m(2) and 0.48 ± 0.1 respectively). Two patients developed significant intraventricular gradients. CONCLUSION: These data show that SJMR 17-mm prostheses can be safely implanted in aortic position in relatively aged patients, offering a satisfactory hemodynamic performance at rest and under DSE, with full utilization of its available orifice, suggesting that a possible mild prosthesis-patient mismatch is not an issue of clinical relevance when this small prosthesis is used. Rest and Dobutamine stress echocardiography is a useful and effective means for evaluating prosthesis hemodynamics and for monitoring the expected LVH regression

    Rest and Dobutamine stress echocardiography in the evaluation of mid-term results of mitral valve repair in Barlow's disease

    Get PDF
    BACKGROUND: Surgical "anatomical" repair is the most frequent technique used to correct mitral regurgitation due to severe myxomatous valve disease. Debate, however, persists on the efficacy of this technique, as well as on the durability of the repaired valve, and on its functioning and hemodynamics under stress conditions. Thus, a basal and Dobutamine echocardiographic (DSE) study was carried out to evaluate these parameters at mid-term follow-up. METHODS AND RESULTS: Twenty patients selected for the study (12 men and 8 women, mean age 60 ± 9 years) underwent pre- and post-operative transthoracic echocardiography (TTE) and intra-operative transesophageal echocardiography (TEE). At mid-term follow-up (20 ± 5 months) all patients underwent rest TTE and DSE (3 min. dose increments up to 40 microg/Kg/min protocol). Pre-discharge and one-month TTE showed absence of MR in 11 pts., trivial or mild MR in 9 pts. and normal mitral valve area and gradients. Mid-term TTE showed decrease in left atrial and ventricular dimension, in pulmonary artery pressure (sPAP) and grade of MR. During DSE a significant increase in mitral valve area, maximum and mean gradients, sPAP, heart rate and cardiac output and a decrease in systolic annular diameter and left ventricular volume were found; in 6 pts. a transient left ventricular outflow tract obstruction was observed. CONCLUSION: Basal and Dobutamine stress echocardiography proved to be valuable tools for evaluation of mid-term results of mitral valve repair. In our study population, the surgical technique employed had a favourable impact on several cardiac parameters, evaluated by these methods
    corecore