17 research outputs found
Radiation dose-rate effects on gene expression for human biodosimetry
Background: The effects of dose-rate and its implications on radiation biodosimetry methods are not well studied in the context of large-scale radiological scenarios. There are significant health risks to individuals exposed to an acute dose, but a realistic scenario would include exposure to both high and low dose-rates, from both external and internal radioactivity. It is important therefore, to understand the biological response to prolonged exposure; and further, discover biomarkers that can be used to estimate damage from low-dose rate exposures and propose appropriate clinical treatment. Methods: We irradiated human whole blood ex vivo to three doses, 0.56 Gy, 2.23 Gy and 4.45 Gy, using two dose rates: acute, 1.03 Gy/min and a low dose-rate, 3.1 mGy/min. After 24 h, we isolated RNA from blood cells and these were hybridized to Agilent Whole Human genome microarrays. We validated the microarray results using qRT-PCR. Results: Microarray results showed that there were 454 significantly differentially expressed genes after prolonged
exposure to all doses. After acute exposure, 598 genes were differentially expressed in response to all doses. Gene ontology terms enriched in both sets of genes were related to immune processes and B-cell mediated immunity. Genes responding to acute exposure were also enriched in functions related to natural killer cell activation and cell-to-cell signaling. As expected, the p53 pathway was found to be significantly enriched at all doses and by both dose-rates of radiation. A support vectors machine classifier was able to distinguish between dose-rates with 100%
accuracy using leave-one-out cross-validation. Conclusions: In this study we found that low dose-rate exposure can result in distinctive gene expression patterns compared with acute exposures. We were able to successfully distinguish low dose-rate exposed samples from acute
dose exposed samples at 24 h, using a gene expression-based classifier. These genes are candidates for further testing as markers to classify exposure based on dose-rate
Estimates of the cancer risks from pediatric CT radiation are not merely theoretical: Comment on “Point/Counterpoint: In x-ray computed tomography, technique factors should be selected appropriate to patient size. Against the Proposition” [Med. Phys. 28,
Dosimetric feasibility of neurovascular bundle-sparing stereotactic body radiotherapy with periprostatic hydrogel spacer for localized prostate cancer to preserve erectile function
Objective: We aim to test the hypothesis that neurovascular bundle (NVB) displacement by rectal hydrogel spacer combined with NVB delineation as an organ at risk (OAR) is a feasible method for NVB-sparing stereotactic body radiotherapy. Methods: Thirty-five men with low- and intermediate-risk prostate cancer who underwent rectal hydrogel spacer placement and pre-, post-spacer prostate MRI studies were treated with prostate SBRT (36.25 Gy in five fractions). A prostate radiologist contoured the NVB on both the pre- and post-spacer T2W MRI sequences that were then registered to the CT simulation scan for NVB-sparing radiation treatment planning. Three SBRT treatment plans were developed for each patient: (1) no NVB sparing, (2) NVB-sparing using pre-spacer MRI, and (3) NVB-sparing using post-spacer MRI. NVB dose constraints include maximum dose 36.25 Gy (100%), V34.4 Gy (95% of dose) <60%, V32Gy <70%, V28Gy <90%. Results: Rectal hydrogel spacer placement shifted NVB contours an average of 3.1 ± 3.4 mm away from the prostate, resulting in a 10% decrease in NVB V34.4 Gy in non-NVB-sparing plans (p < 0.01). NVB-sparing treatment planning reduced the NVB V34.4 by 16% without the spacer (p < 0.01) and 25% with spacer (p < 0.001). NVB-sparing did not compromise PTV coverage and OAR endpoints. Conclusions: NVB-sparing SBRT with rectal hydrogel spacer significantly reduces the volume of NVB treated with high-dose radiation. Rectal spacer contributes to this effect through a dosimetrically meaningful displacement of the NVB that may significantly reduce RiED. These results suggest that NVB-sparing SBRT warrants further clinical evaluation. Advances in knowledge: This is a feasibility study showing that the periprostatic NVBs can be spared high doses of radiation during prostate SBRT using a hydrogel spacer and nerve-sparing treatment planning. </jats:sec
Stereotactic body radiotherapy with periprostatic hydrogel spacer for localized prostate cancer: toxicity profile and early oncologic outcomes
Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography.
BACKGROUND: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated.
METHODS: Radiation doses from CCTA to critical organs were determined using metal-oxide-semiconductor field-effect transistors positioned in a customized anthropomorphic whole-body dosimetry verification phantom. Image noise and signal were measured in regions of interest (ROIs) including the coronary arteries.
RESULTS: With bismuth shielding, breast radiation dose was reduced 46%-57% depending on breast size and scanning technique, with more moderate dose reduction to the heart, lungs, and esophagus. However, shielding significantly decreased image signal (by 14.6 HU) and contrast (by 28.4 HU), modestly but significantly increased image noise in ROIs in locations of coronary arteries, and decreased contrast-to-noise ratio by 20.9%.
CONCLUSIONS: While bismuth breast shielding can significantly decrease radiation dose to critical organs, it is associated with an increase in image noise, decrease in contrast-to-noise, and changes tissue attenuation characteristics in the location of the coronary arteries
Effect of bismuth breast shielding on radiation dose and image quality in coronary CT angiography
BACKGROUND: Coronary computed tomographic angiography (CCTA) is associated with high radiation dose to the female breasts. Bismuth breast shielding offers the potential to significantly reduce dose to the breasts and nearby organs, but the magnitude of this reduction and its impact on image quality and radiation dose have not been evaluated. METHODS: Radiation doses from CCTA to critical organs were determined using metal-oxide-semiconductor field-effect transistors positioned in a customized anthropomorphic whole-body dosimetry verification phantom. Image noise and signal were measured in regions of interest (ROIs) including the coronary arteries. RESULTS: With bismuth shielding, breast radiation dose was reduced 46–57% depending on breast size and scanning technique, with more moderate dose reduction to the heart, lungs, and esophagus. However, shielding significantly decreased image signal (by 14.6 HU) and contrast (by 28.4 HU), modestly but significantly increased image noise in ROIs in locations of coronary arteries, and decreased contrast-to-noise ratio by 20.9%.. CONCLUSIONS: While bismuth breast shielding can significantly decrease radiation dose to critical organs, it is associated with an increase in image noise, decrease in contrast-to-noise, and changes tissue attenuation characteristics in the location of the coronary arteries