309 research outputs found

    The ICARUS T600 Detector at LNGS Underground Laboratory

    Get PDF
    Abstract ICARUS (Imaging Cosmic And Rare Underground Signals) is the the largest Liquid Argon Time Projection Chamber (LAr-TPC) in the world (containing _600 tons of LAr) addressed to the study of rare events and, among these, neutrino interactions. Installed in the Gran Sasso National Laboratory (INFN-LNGS, Italy), ICARUS started working gradually since May, 27th 2010, collecting data both from the cosmic rays able to reach the depths of the laboratory and from neutrino interactions from the CNGS beam. The detector, providing a completely uniform imaging and calorimetry with a high accuracy on massive volumes, allows to reconstruct in real time neutrino and cosmic interactions, measuring the full kinematics of the identified particles. The ICARUS technology can be considered as a milestone towards the realization of next generation of massive detectors (tens of ktons) for neutrino and rare event phy sics.In this paper a short description of the ICARUS T600 experiment, detector main features and performances and its first underground results are presented

    VUV-Vis optical characterization of Tetraphenyl-butadiene films on glass and specular reflector substrates from room to liquid Argon temperature

    Full text link
    The use of efficient wavelength-shifters from the vacuum-ultraviolet to the photosensor's range of sensitivity is a key feature in detectors for Dark Matter search and neutrino physics based on liquid argon scintillation detection. Thin film of Tetraphenyl-butadiene (TPB) deposited onto the surface delimiting the active volume of the detector and/or onto the photosensor optical window is the most common solution in current and planned experiments. Detector design and response can be evaluated and correctly simulated only when the properties of the optical system in use (TPB film + substrate) are fully understood. Characterization of the optical system requires specific, sometimes sophisticated optical methodologies. In this paper the main features of TPB coatings on different, commonly used substrates is reported, as a result of two independent campaigns of measurements at the specialized optical metrology labs of ENEA and University of Tor Vergata. Measured features include TPB emission spectra with lineshape and relative intensity variation recorded as a function of the film thickness and for the first time down to LAr temperature, as well as optical reflectance and transmittance spectra of the TPB coated substrates in the wavelength range of the TPB emission

    Neutron to Gamma Pulse Shape Discrimination in Liquid Argon Detectors with High Quantum Effciency Photomultiplier Tubes

    Get PDF
    Abstract A high Light Yield Liquid Argon chamber has been radiated with an Am/Be source for signal-to-background separation level characterization in a Dark Matter Liquid Argon based detector. Apart from the standard nuclear recoil and electron events, from neutron elastic interactions and gamma conversions respectively, an intermediate population has been observed which is attributed to inelastic neutron scatters on Argon nuclei producing Argon recoil and simultaneous gammas from nuclear de-excitation. Taking account of these events results in a better determination of the recoil-like to electron-like separation based on the shape of the scintillation pulse. The results of this recent study as well as from a previous study with a chamber with a lower Light Yield are presented

    A versatile cryogenic system for liquid argon detectors

    Full text link
    Detectors for direct dark matter search using noble gases in liquid phase as detection medium need to be coupled to liquefaction, purification and recirculation systems. A dedicated cryogenic system has been assembled and operated at the INFN-Naples cryogenic laboratory with the aim to liquefy and purify the argon used as active target in liquid argon detectors to study the scintillation and ionization signals detected by large SiPMs arrays. The cryogenic system is mainly composed of a double wall cryostat hosting the detector, a purification stage to reduce the impurities below one part per billion level, a condenser to liquefy the argon, a recirculation gas panel connected to the cryostat equipped with a custom gas pump. The main features of the cryogenic system are reported as well as the performances, long term operations and stability in terms of the most relevant thermodynamic parameters.Comment: Prepared for submission to JINST - LIDINE2022 September 21-23, 2022 - University of Warsaw Librar

    First Tests of a New Fast Waveform Digitizer for PMT Signal Read-out from Liquid Argon Dark Matter Detectors

    Get PDF
    Abstract A new generation Waveform Digitizer board as been recently made available on the market by CAEN. The new board CAEN V1751 with 8 Channels per board, 10 bit, 1 GS/s Flash ADC Waveform Digitizer (or 4 channel, 10 bit, 2 GS/s Flash ADC Waveform Digitizer -Dual Edge Sampling mode) with threshold and Auto-Trigger capabilities provides an ideal (relatively low-cost) solution for reading signals from liquid Argon detectors for Dark Matter search equipped with an array of PMTs for the detection of scintillation light. The board was extensively used in real experimental conditions to test its usefulness for possible future uses and to compare it with a state of the art digital oscilloscope. As results, PMT Signal sampling at 1 or 2 GS/s is appropriate for the reconstruction of the fast component of the signal scintillation in Argon (characteristic time of about 4 ns) and the extended dynamic range, after a small customization, allows for the detection of signals in the range of energy needed. The bandwidth is found to be adequate and the intrinsic noise is very low

    Solar neutrino detection in a large volume double-phase liquid argon experiment

    Full text link
    Precision measurements of solar neutrinos emitted by specific nuclear reaction chains in the Sun are of great interest for developing an improved understanding of star formation and evolution. Given the expected neutrino fluxes and known detection reactions, such measurements require detectors capable of collecting neutrino-electron scattering data in exposures on the order of 1 ktonne yr, with good energy resolution and extremely low background. Two-phase liquid argon time projection chambers (LAr TPCs) are under development for direct Dark Matter WIMP searches, which possess very large sensitive mass, high scintillation light yield, good energy resolution, and good spatial resolution in all three cartesian directions. While enabling Dark Matter searches with sensitivity extending to the "neutrino floor" (given by the rate of nuclear recoil events from solar neutrino coherent scattering), such detectors could also enable precision measurements of solar neutrino fluxes using the neutrino-electron elastic scattering events. Modeling results are presented for the cosmogenic and radiogenic backgrounds affecting solar neutrino detection in a 300 tonne (100 tonne fiducial) LAr TPC operating at LNGS depth (3,800 meters of water equivalent). The results show that such a detector could measure the CNO neutrino rate with ~15% precision, and significantly improve the precision of the 7Be and pep neutrino rates compared to the currently available results from the Borexino organic liquid scintillator detector.Comment: 21 pages, 7 figures, 6 table

    Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature

    Full text link
    Liquified noble gases are widely used as a target in direct Dark Matter searches. Signals from scintillation in the liquid, following energy deposition from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should be recorded down to very low energies by photosensors suitably designed to operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter searches currently implement photo multiplier tubes for signal read-out. In the last few years PMTs with photocathodes operating down to liquid Argon temperatures (87 K) have been specially developed with increasing Quantum Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod. R11065 with peak QE up to about 35%, has been extensively tested within the R&D program of the WArP Collaboration. During these testes the Hamamatsu PMTs showed superb performance and allowed obtaining a light yield around 7 phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12% range, sufficient for detection of events down to few keVee of energy deposition. This shows that this new type of PMT is suited for experimental applications, in particular for new direct Dark Matter searches with LAr-based experiments

    Direct evidence of milk consumption from ancient human dental calculus.

    Get PDF
    Milk is a major food of global economic importance, and its consumption is regarded as a classic example of gene-culture evolution. Humans have exploited animal milk as a food resource for at least 8500 years, but the origins, spread, and scale of dairying remain poorly understood. Indirect lines of evidence, such as lipid isotopic ratios of pottery residues, faunal mortality profiles, and lactase persistence allele frequencies, provide a partial picture of this process; however, in order to understand how, where, and when humans consumed milk products, it is necessary to link evidence of consumption directly to individuals and their dairy livestock. Here we report the first direct evidence of milk consumption, the whey protein ÎČ-lactoglobulin (BLG), preserved in human dental calculus from the Bronze Age (ca. 3000 BCE) to the present day. Using protein tandem mass spectrometry, we demonstrate that BLG is a species-specific biomarker of dairy consumption, and we identify individuals consuming cattle, sheep, and goat milk products in the archaeological record. We then apply this method to human dental calculus from Greenland's medieval Norse colonies, and report a decline of this biomarker leading up to the abandonment of the Norse Greenland colonies in the 15(th) century CE
    • 

    corecore