7 research outputs found
Syncope Recurrence and Downstream Diagnostic Testing after Insertable Cardiac Monitor Placement for Syncope
Despite advances in syncope evaluation strategies and risk stratification, the high cost of syncope is largely driven by extensive and often repetitive testing. This analysis of a large deidentified US claims database compared the use of diagnostic tests, therapeutic procedures, and the recurrence rate of acute syncope events before and after placement of an insertable cardiac monitor (ICM) in syncope patients. The patients had a minimum of 1 year of continuous enrollment before and 2 years after ICM placement. Among 2140 patients identified, a statistically significant reduction in the use of 14 out of 18 tests was observed during follow-up compared with pre-ICM testing. During the 2-year follow-up, 28.3% of patients underwent cardiac therapeutic interventions after a median of 127 days. Significantly fewer patients experienced acute syncope events during the 1st and 2nd years of ICM follow-up compared with the 1-year pre-ICM period, and the frequency of events per patient also decreased. In conclusion, reductions in diagnostic testing and acute syncope events were observed after ICM placement in a large real-world cohort of unexplained syncope patients. Further studies are needed to prospectively assess the impact of ICM vs. short-term monitoring on patient outcomes and healthcare utilization
Recommended from our members
Enhancing patient acceptance of ICD implantation through structured shared decision making: conversation is key
Implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D) are lifesaving treatments for patients at risk for sudden cardiac death. Effective physician-patient communication during the shared decision-making process is essential. Electrophysiologist-patient conversations were targeted to obtain objective data on the interaction, understand the conversation framework, and uncover opportunities for improved communication.BACKGROUNDImplantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D) are lifesaving treatments for patients at risk for sudden cardiac death. Effective physician-patient communication during the shared decision-making process is essential. Electrophysiologist-patient conversations were targeted to obtain objective data on the interaction, understand the conversation framework, and uncover opportunities for improved communication.Individuals previously identified as requiring an ICD/CRT-D but declined implantation were recruited for this four-stage interview and survey-based study. Quantitative analysis of surveys and AI analysis of conversation videos was conducted to evaluate patient participant expectations, analyze feedback about the conversations with study physicians, and gauge willingness for device implantation.METHODSIndividuals previously identified as requiring an ICD/CRT-D but declined implantation were recruited for this four-stage interview and survey-based study. Quantitative analysis of surveys and AI analysis of conversation videos was conducted to evaluate patient participant expectations, analyze feedback about the conversations with study physicians, and gauge willingness for device implantation.The study included 27 patients (mean age 51 years, 51.9% female) and 9 study physicians. Patients were significantly more willing to undergo ICD/CRT-D implantation after conversing with study physicians compared to their own physicians and pre-conversation surveys (mean scores: 5.0, 3.1, and 4.4 out of 7, respectively; p < 0.001). Patient participants had higher satisfaction with the study conversation, rating study physicians higher in effectiveness of explanations, responsiveness to questions, and overall quality of the conversation compared to their own physicians (all p < 0.001).RESULTSThe study included 27 patients (mean age 51 years, 51.9% female) and 9 study physicians. Patients were significantly more willing to undergo ICD/CRT-D implantation after conversing with study physicians compared to their own physicians and pre-conversation surveys (mean scores: 5.0, 3.1, and 4.4 out of 7, respectively; p < 0.001). Patient participants had higher satisfaction with the study conversation, rating study physicians higher in effectiveness of explanations, responsiveness to questions, and overall quality of the conversation compared to their own physicians (all p < 0.001).In a cohort of patients who previously declined ICD/CRT-D implantation, patient satisfaction and willingness to undergo implantation of a guideline-directed device therapy increased significantly following a structured conversation with study physicians. Identified key elements could be integrated into user-friendly tools and educational materials to facilitate these conversations, improving patient engagement with the decision-making process and enhancing informed acceptance of indicated device therapies.CONCLUSIONSIn a cohort of patients who previously declined ICD/CRT-D implantation, patient satisfaction and willingness to undergo implantation of a guideline-directed device therapy increased significantly following a structured conversation with study physicians. Identified key elements could be integrated into user-friendly tools and educational materials to facilitate these conversations, improving patient engagement with the decision-making process and enhancing informed acceptance of indicated device therapies
Enhancing patient acceptance of ICD implantation through structured shared decision making: conversation is key.
Implantable cardioverter-defibrillators (ICDs) and cardiac resynchronization therapy defibrillators (CRT-D) are lifesaving treatments for patients at risk for sudden cardiac death. Effective physician-patient communication during the shared decision-making process is essential. Electrophysiologist-patient conversations were targeted to obtain objective data on the interaction, understand the conversation framework, and uncover opportunities for improved communication. Individuals previously identified as requiring an ICD/CRT-D but declined implantation were recruited for this four-stage interview and survey-based study. Quantitative analysis of surveys and AI analysis of conversation videos was conducted to evaluate patient participant expectations, analyze feedback about the conversations with study physicians, and gauge willingness for device implantation. The study included 27 patients (mean age 51 years, 51.9% female) and 9 study physicians. Patients were significantly more willing to undergo ICD/CRT-D implantation after conversing with study physicians compared to their own physicians and pre-conversation surveys (mean scores: 5.0, 3.1, and 4.4 out of 7, respectively; p < 0.001). Patient participants had higher satisfaction with the study conversation, rating study physicians higher in effectiveness of explanations, responsiveness to questions, and overall quality of the conversation compared to their own physicians (all p < 0.001). In a cohort of patients who previously declined ICD/CRT-D implantation, patient satisfaction and willingness to undergo implantation of a guideline-directed device therapy increased significantly following a structured conversation with study physicians. Identified key elements could be integrated into user-friendly tools and educational materials to facilitate these conversations, improving patient engagement with the decision-making process and enhancing informed acceptance of indicated device therapies. [Abstract copyright: © 2024. The Author(s).
Antibacterial Envelope to Prevent Cardiac Implantable Device Infection
Background Infections after placement of cardiac implantable electronic devices (CIEDs) are associated with substantial morbidity and mortality. There is limited evidence on prophylactic strategies, other than the use of preoperative antibiotics, to prevent such infections. Methods We conducted a randomized, controlled clinical trial to assess the safety and efficacy of an absorbable, antibiotic-eluting envelope in reducing the incidence of infection associated with CIED implantations. Patients who were undergoing a CIED pocket revision, generator replacement, or system upgrade or an initial implantation of a cardiac resynchronization therapy defibrillator were randomly assigned, in a 1:1 ratio, to receive the envelope or not. Standard-of-care strategies to prevent infection were used in all patients. The primary end point was infection resulting in system extraction or revision, long-term antibiotic therapy with infection recurrence, or death, within 12 months after the CIED implantation procedure. The secondary end point for safety was procedure-related or system-related complications within 12 months. Results A total of 6983 patients underwent randomization: 3495 to the envelope group and 3488 to the control group. The primary end point occurred in 25 patients in the envelope group and 42 patients in the control group (12-month Kaplan-Meier estimated event rate, 0.7% and 1.2%, respectively; hazard ratio, 0.60; 95% confidence interval [CI], 0.36 to 0.98; P=0.04). The safety end point occurred in 201 patients in the envelope group and 236 patients in the control group (12-month Kaplan-Meier estimated event rate, 6.0% and 6.9%, respectively; hazard ratio, 0.87; 95% CI, 0.72 to 1.06; P<0.001 for noninferiority). The mean (+/- SD) duration of follow-up was 20.7 +/- 8.5 months. Major CIED-related infections through the entire follow-up period occurred in 32 patients in the envelope group and 51 patients in the control group (hazard ratio, 0.63; 95% CI, 0.40 to 0.98). Conclusions Adjunctive use of an antibacterial envelope resulted in a significantly lower incidence of major CIED infections than standard-of-care infection-prevention strategies alone, without a higher incidence of complications