100 research outputs found
Gastric normal adjacent mucosa versus healthy and cancer tissues: Distinctive transcriptomic profiles and biological features
Gastric cancer (GC) is a leading cause of cancer-related deaths in the world. Molecular heterogeneity is a major determinant for the clinical outcomes and an exhaustive tumor classification is currently missing. Histologically normal tissue adjacent to the tumor (NAT) is commonly used as a control in cancer studies, nevertheless a recently published paper described the unique characteristics of the NAT in several tumor types. Little is known about the global gene expression profile of gastric NAT (gNAT) which could be an effective tool for a more realistic definition of GC molecular signature. Here, we integrated data of 512 samples from the Genotype- Tissue Expression project (GETx) and The Cancer Genome Atlas (TCGA) to analyze the transcriptome of healthy gastric tissues, gNAT, and GC samples. We validated TCGA-GETx data mining through inHouse gNAT and GC expression dataset. Differential gene expression together with pathway enrichment analyses, indeed, led to different results when using the gNAT or the healthy tissue as control. Based on our analyses, gNAT showed a peculiar gene signature and biological features, like the estrogen receptor pathways activation, suggesting a molecular behavior partially different from both healthy and GC tissues. Therefore, using gNAT as healthy control tissue in the characterization of tumor associated biological processes and pathways could lead to suboptimal results
Urban Heat Island Effect on the Energy Consumption of Institutional Buildings in Rome
The urban heat island (UHI) effect is constantly increasing the energy consumption of buildings, especially in summer periods. The energy gap between the estimated energy performance - often simulated without considering UHI - and the real operational consumption is especially relevant for institutional buildings, where the cooling needs are in general higher than in other kind of buildings, due to more internal gains (people, appliances) and different architectural design (more transparent façades and light walls). This paper presents a calculation of the energy penalty due to UHI in two institutional buildings in Rome. Urban Weather Generator (UWG) is used to generate a modified weather file, taking into account the UHI phenomenon. Then, two building performance simulations are done for each case: the first simulation uses a standard weather file and the second uses the modified one. Results shows how is it necessary to re-develop mitigation strategies and a new energy retrofit approach, in order to include urbanization ad UHI effect, especially in this kind of buildings, characterized by very poor conditions of comfort during summer, taking into account users and occupant-driven demand
Diagnostic performance of salivary urea nitrogen dipstick to detect and monitor acute kidney disease in patients with malaria
BACKGROUND: Acute kidney injury (AKI) is a common complication of malaria. In low resource settings, a lack of diagnostic tools and delayed treatment of malaria associated AKI lead to significant morbidity and mortality. The aim of this study was to assess the diagnostic performance of salivary urea nitrogen (SUN) dipstick to detect and monitor kidney disease [KD = AKI or acute kidney disease (AKD) without AKI] in malaria patients in Angola. METHODS: Patients 11–50 years old admitted with malaria at the Josina Machel (Maria-Pia) Hospital, Luanda, Angola, between 2nd March and 10th May 2016 were enrolled in this study. All participants had serum creatinine (sCr), blood urea nitrogen (BUN) and SUN dipstick tested at the time of recruitment and daily for up to 4 days. AKD without AKI refers to acute renal impairment which do not fulfilled the main criteria for AKI (increases in the baseline serum creatinine and/or decreases in urine output) according defined by the kidney disease improving global outcomes (KDIGO) guideline. RESULTS: Eight-six patients were admitted with malaria diagnosis (mean age 21.5 ± 9.4 years, 71% male) and 27 (32%) were diagnosed with KD. The mean (± SD) sCr and BUN of the KD group at admission (day 0) were 5.38 (± 5.42) and 99.4 (± 61.9) mg/dL, respectively. Three (3.5%) patients underwent haemodialysis and eight (9.3%) died within the first 4 days of hospital admission [5 (62.5%) with KD; 3 (37.5%) without kidney disease; p = 0.047]. The SUN threshold for KD diagnosis was tested pad #5 (SUN > 54 mg/dL). At this threshold, the SUN dipstick had a sensitivity of 67% and specificity of 98% to diagnose KD. The area under the receiver operating characteristics curve (ROC) for KD diagnosis on admission was 0.88 (95% CI 0.79–0.96). The SUN dipstick was most accurate at higher levels of BUN. CONCLUSION: The SUN dipstick had reasonable sensitivity and excellent specificity when used to diagnose KD in a cohort of patients with malaria in a resource-limited setting. Given the severity of presenting illness and kidney injury, the SUN dipstick diagnostic threshold was high (test pad #5). SUN may be used to detect AKI in patients with malaria in low resources settings, thus facilitating earlier access to adequate treatment, which may improve survival
Shower development of particles with momenta from 15 GeV to 150 GeV in the CALICE scintillator-tungsten hadronic calorimeter
We present a study of showers initiated by electrons, pions, kaons, and
protons with momenta from 15 GeV to 150 GeV in the highly granular CALICE
scintillator-tungsten analogue hadronic calorimeter. The data were recorded at
the CERN Super Proton Synchrotron in 2011. The analysis includes measurements
of the calorimeter response to each particle type as well as measurements of
the energy resolution and studies of the longitudinal and radial shower
development for selected particles. The results are compared to Geant4
simulations (version 9.6.p02). In the study of the energy resolution we include
previously published data with beam momenta from 1 GeV to 10 GeV recorded at
the CERN Proton Synchrotron in 2010.Comment: 35 pages, 21 figures, 8 table
Pion and proton showers in the CALICE scintillator-steel analogue hadron calorimeter
Showers produced by positive hadrons in the highly granular CALICE
scintillator-steel analogue hadron calorimeter were studied. The experimental
data were collected at CERN and FNAL for single particles with initial momenta
from 10 to 80 GeV/c. The calorimeter response and resolution and spatial
characteristics of shower development for proton- and pion-induced showers for
test beam data and simulations using Geant4 version 9.6 are compared.Comment: 26 pages, 16 figures, JINST style, changes in the author list, typos
corrected, new section added, figures regrouped. Accepted for publication in
JINS
Performance of the first prototype of the CALICE scintillator strip electromagnetic calorimeter
A first prototype of a scintillator strip-based electromagnetic calorimeter
was built, consisting of 26 layers of tungsten absorber plates interleaved with
planes of 45x10x3 mm3 plastic scintillator strips. Data were collected using a
positron test beam at DESY with momenta between 1 and 6 GeV/c. The prototype's
performance is presented in terms of the linearity and resolution of the energy
measurement. These results represent an important milestone in the development
of highly granular calorimeters using scintillator strip technology. This
technology is being developed for a future linear collider experiment, aiming
at the precise measurement of jet energies using particle flow techniques
The Time Structure of Hadronic Showers in highly granular Calorimeters with Tungsten and Steel Absorbers
The intrinsic time structure of hadronic showers influences the timing
capability and the required integration time of hadronic calorimeters in
particle physics experiments, and depends on the active medium and on the
absorber of the calorimeter. With the CALICE T3B experiment, a setup of 15
small plastic scintillator tiles read out with Silicon Photomultipliers, the
time structure of showers is measured on a statistical basis with high spatial
and temporal resolution in sampling calorimeters with tungsten and steel
absorbers. The results are compared to GEANT4 (version 9.4 patch 03)
simulations with different hadronic physics models. These comparisons
demonstrate the importance of using high precision treatment of low-energy
neutrons for tungsten absorbers, while an overall good agreement between data
and simulations for all considered models is observed for steel.Comment: 24 pages including author list, 9 figures, published in JINS
Hadron shower decomposition in the highly granular CALICE analogue hadron calorimeter
The spatial development of hadronic showers in the CALICE scintillator-steel
analogue hadron calorimeter is studied using test beam data collected at CERN
and FNAL for single positive pions and protons with initial momenta in the
range from 10 to 80 GeV/c. Both longitudinal and radial development of hadron
showers are parametrised with two-component functions. The parametrisation is
fit to test beam data and simulations using the QGSP_BERT and FTFP_BERT physics
lists from Geant4 version 9.6. The parameters extracted from data and simulated
samples are compared for the two types of hadrons. The response to pions and
the ratio of the non-electromagnetic to the electromagnetic calorimeter
response, h/e, are estimated using the extrapolation and decomposition of the
longitudinal profiles.Comment: 38 pages, 19 figures, 5 tables; author list changed; submitted to
JINS
A Salivary Urea Nitrogen Dipstick to Detect Obstetric-Related Acute Kidney Disease in Malawi
Introduction: Obstetric-related acute kidney injury (AKI) is associated with adverse outcomes for mother and fetus, particularly in low-income countries. However, laboratory-independent tools to facilitate diagnosis are lacking. We assessed the diagnostic performance of a salivary urea nitrogen (SUN) dipstick to detect obstetric-related acute kidney disease in Malawi. / Methods: Women at high risk for AKI admitted to an obstetric unit in Blantyre, Malawi, were recruited between 21 September and 11 December 2015. Patients underwent serum creatinine (SCr) testing alongside measurement of SUN using a dipstick on admission, and every 48 hours thereafter if evidence of kidney disease was found. / Results: A total of 301 patients were included (mean age 25.9 years, 11% HIV positive). Of the patients, 23 (7.6%) had AKI, stage 1 in 47.8%, most commonly due to preeclampsia/eclampsia. Mean presenting SCr values were 108.8 ± 21.8 μmol/l (1.23 ± 0.25 mg/dl), 118 ± 34.45 μmol/l (1.33 ± 0.39 mg/dl), and 136.1 ± 30.4 μmol/l (1.54 ± 0.34 mg/dl) in AKI stages 1 to 3 respectively. SUN > 14 mg/dl had a sensitivity of 12.82% and a specificity of 97.33% to detect acute kidney disease; the area under the receiver operating characteristic curve was 0.551. In patients with normal SUN on admission, perinatal mortality was 11.8%, and was 25.0% if SUN was?> 14 mg/dl (P = 0.18). / Conclusion: The SUN dipstick was specific but insensitive when used to diagnose obstetric-related AKI. Limited biochemical derangement and low salivary urea concentrations due to physiological changes in pregnancy, as opposed to a technical limitation of the dipstick itself, are the likely reason for the lack of sensitivity in this study
- …