4 research outputs found
Precipitación de fierro y manganeso secuencial de efluentes de drenaje ácidos
Acid effluents from the leaching of sulphide minerals could be a liability that will return part of the cost of treatment when economic elements such as Fe and Mn are obtained. In this practical part of the neutralization with lime, it is precipitated as ferric hydroxides (III) and manganese (IV) hydroxides the pH must be controlled for each stage. Although the pH initially started at 2.2, an effluent has been achieved according to the standards established for its discharge or reuse. Dry hydroxides can reach very profitable levels, making the treatment sustainable and also clearing metals from the sludge that commonly goes to the tailings.Los efluentes ácidos de la lixiviación de los minerales sulfurados podrían ser un pasivo que retornara parte de su costo de tratamiento al ser obtenidos los elementos económicos, como el Fe y Mn. En esta práctica parte de la neutralización con cal, se precipita como hidróxidos férricos (III) e hidróxidos de manganeso (IV) se debe controlar el pH para cada etapa. Aunque el pH al comienzo empezó en 2.2, Se ha logrado un efluente de acuerdo con los estándares establecidos para su vertimiento o reutilización. Los hidróxidos secos pueden alcanzar niveles muy rentables, haciendo sostenible el tratamiento y además despejando de metales a los lodos que comúnmente van a la relavera
Modelo matemático para la recuperación de oro y zinc mediante el proceso de flotación a partir de minerales sulfurados de zinc marmatitico en la provincia de Casma – Ancash
The present research study demonstrates that the recovery of gold and zinc in gold-containing marmatitic zinc ores is feasible. The recovery of these metals was analyzed by factorial experimental designs, using the reagents: CuSO4, AR-3418 and AR-1242 as independent variables, while all other variables remained constant.
As a result of the research, a mathematical model was obtained for the recovery of gold and zinc, performing the adjusted factorial design analysis, as indicated:
Recovery of gold (Au) = 83.40+ 0.00600 CuSO4 + 0.110 AR-3418 + 0.035 AR-1242 + 0.000313 CuSO4 * AR 3418+ 0.000275 CuSO4 * AR-1242- 0.00800 AR-3418 * AR-1242 - 0.000011 CuSO4 * AR-3418 * AR-1242.
Likewise, the recovery of zinc (Zn) = 73.14 + 0.0100 CuSO4 + 0.132 AR-3418 + 0.051 AR-1242 + 0.000164 CuSO4 * AR-3418 + 0.000131 CuSO4 * AR-1242 - 0.00811 AR-3418 * AR-1242 - 0.000004 CuSO4 * AR-3418 * AR-1242.El presente estudio de investigación demuestra que es viable la recuperación de oro y zinc en minerales de zinc marmatitico con contenido de oro. Se analizó la recuperación de oro y zinc mediante diseños experimentales factoriales, utilizando los reactivos: CuSO4, AR-3418 y AR-1242 como variables independientes; el resto de las variables se mantuvieron constantes.
Como resultado de la investigación se obtuvo un modelo para la recuperación de oro y zinc, realizando el análisis del diseño factorial ajustado como se indica:
Recuperación de Au = 83.40+ 0.00600 CuSO4+ 0.110 AR-3418+ 0.035 AR-1242+ 0.000313 CuSO4*AR 3418+ 0.000275 CuSO4*AR-1242- 0.00800 AR-3418*AR-1242 - 0.000011 CuSO4*AR-3418*AR-1242.
Asimismo, la recuperación de Zn = 73.14 + 0.0100 CuSO4+ 0.132 AR-3418+ 0.051 AR-1242 + 0.000164 CuSO4*AR-3418 + 0.000131 CuSO4*AR-1242 - 0.00811 AR-3418*AR-1242 - 0.000004 CuSO4*AR-3418*AR-1242
Effect of sodium hypochlorite and sodium sulfide in the treatment of metallurgical cyanide effluent
La cianuración se aplica en el tratamiento de minerales de oro para obtener oro en solución libre de material estéril, producto de este tratamiento resulta un efluente que hay que tratarlo antes de realizar la descarga al mar o a los ríos. Esta investigación tiene la finalidad de elaborar una metodología para tratar el efluente con contenido alto de cianuro libre. Se estudió el efluente proveniente de la cianuración de oro. Los resultados antes del tratamiento fue de 4917 ppm de cianuro, también se logró determinar la concentración óptima de hipoclorito de sodio y esta es 30 a 60 gr/l y la de sulfuro de sodio, de 10 a 16 g/l en un tiempo de 4 a 7 horas; después del tratamiento la cantidad de cianuro en el efluente disminuyó de 4917 ppm al rango de 0,0611 – 0,1645 ppm. Se caracterizó el efluente para diseñar el tratamiento. Se concluye que con el tratamiento del efluente, se logró reducir el cianuro a cantidades menores de 1 ppm, lo que está dentro de los límites, máximos permisibles de descargas.The cyanide is applied in the treatment of gold ores for gold in free solution sterile material product of this treatment is an effluent that must be treated prior to discharge to the sea or rivers. This research aims to develop a methodology for treating the effluent with high free cyanide. The population studied was the effluent from gold cyanidation The results before treatment was 4917 ppm cyanide, is also able to determine the optimum concentration of sodium hypochlorite was 30 to 60 g/l and sodium sulfide was 10 to 16 g/l in a time of 4 to 7 hours after treatment the quantity of cyanide in the effluent decreased from 4917 ppm to the range of 0,0611 to 0,1645 ppm . We have characterized the effluent to design treatment. The conclusion was that the treatment of the effluent cyanide was reduced to smaller quantities of 1 ppm which is within the maximum allowable discharge limits
Gestión de residuos biocontaminados en establecimientos de salud administrados por los gobiernos regionales del Perú
Health facilities generate thousands of tons of waste each year, including non-hazardous waste, hazardous substances, radioactive substances, and infectious substances. This number is increasing as our country continues to develop, as is public concern about its negative effects on human health. Through this study, an adequate management of hospital waste from its origin to its final disposal is suggested, focusing on the correct segregation of waste, since this will minimize the impact. In each medical facility it is necessary to establish a biological treatment system for contaminated waste; in accordance with the provisions of the Hygiene Technical Reference: "Management and total management of solid waste in health establishments, medical support services and research centers", through which the physical, chemical or biological properties of the biologically contaminated waste, to reduce or eliminate the potential danger to your health and the environment, until its final disposal. For this reason, we consider that in each seat of regional government a plan for the generation of biocontaminated waste from EESS should be implemented, managed by the Ministry of Health, with alternative treatment solutions to disinfect biocontaminated waste, the receptivity of the infrastructure for final treatment of biological polluting waste, in an ecological environment.Los establecimientos de salud generan miles de toneladas de desechos cada año, incluidos desechos no peligrosos, sustancias peligrosas, sustancias radiactivas y sustancias infecciosas. Este número aumenta a medida que nuestro país continúa desarrollándose, al igual que la preocupación pública por sus efectos negativos en la salud humana. A través de este estudio se sugiere una adecuada gestión de los residuos hospitalarios desde su origen hasta su disposición final, enfocándose en la correcta segregación de los residuos, ya que esto minimizará el impacto. En cada establecimiento médico es necesario establecer un sistema de tratamiento biológico para los desechos contaminados; de conformidad con lo establecido en la Referencia Técnica de Higiene: “Gestión y manejo total de residuos sólidos en establecimientos de salud, servicios de apoyo médico y centros de investigación”, a través del cual se evaluarán las propiedades físicas, químicas o biológicas de los residuos biológicamente contaminados, para reducir o eliminar el peligro potencial para su salud y el medio ambiente, hasta su disposición final. Por ello, consideramos en cada sede de gobierno regional debería de implementarse un plan de generación de residuos biocontaminados de los EESS, gestionado por el Ministerio de Salud, con soluciones alternativas de tratamiento para desinfectar residuos biocontaminados, la receptividad de la infraestructura para el tratamiento final de residuos contaminantes biológicos, en un entorno ecológico