9,114 research outputs found

    Functional and anatomic correlates of two frequently observed temporal lobe seizure-onset patterns.

    Get PDF
    Intracranial depth electrode EEG records of 478 seizures, recorded in 68 patients undergoing diagnostic monitoring with depth electrodes, were evaluated to investigate the correlates of electrographic onset patterns in patients with temporal lobe seizures. The seizure onsets in 78% of these patients were identified as either hypersynchronous onsets, beginning with low-frequency, high-amplitude spikes, or low-voltage fast (LVF) onsets, increasing in amplitude as the seizure progressed. The number of patients (35) having hypersynchronous seizure onsets was nearly twice that of patients (18) having LVF onsets. Three major differences were seen among patients with the two seizure-onset patterns. When compared with patients having LVF onsets, patients with hypersynchronous seizure onsets had a significantly greater probability of having (1) focal rather than regional seizure onsets (p < 0.01), (2) seizures spreading more slowly to the contralateral mesial temporal lobe (p < 0.003), and (3) cell counts in resected hippocampal tissue showing greater neuronal loss (p < 0.001). The results provide evidence that the most frequent electrographic abnormality associated with mesial temporal seizures is local hypersynchrony, a condition associated with major neuronal loss in the hippocampus. The results also indicate that LVF seizure onsets more frequently represent widely distributed discharges, which interact with and spread more rapidly to surrounding neocortical areas

    Studies of proton irradiated 0.9PMN-0.1PT/P(VDF-TrFE) 0-3 composites

    Get PDF
    2001-2002 > Academic research: refereed > Refereed conference paperVersion of RecordPublishe

    Coffee consumption and prostate cancer risk: further evidence for inverse relationship

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Higher consumption of coffee intake has recently been linked with reduced risk of aggressive prostate cancer (PC) incidence, although meta-analysis of other studies that examine the association between coffee consumption and overall PC risk remains inconclusive. Only one recent study investigated the association between coffee intake and grade-specific incidence of PC, further evidence is required to understand the aetiology of aggressive PCs. Therefore, we conducted a prospective study to examine the relationship between coffee intake and overall as well as grade-specific PC risk.</p> <p>Methods</p> <p>We conducted a prospective cohort study of 6017 men who were enrolled in the Collaborative cohort study in the UK between 1970 and 1973 and followed up to 31st December 2007. Cox Proportional Hazards Models were used to evaluate the association between coffee consumption and overall, as well as Gleason grade-specific, PC incidence.</p> <p>Results</p> <p>Higher coffee consumption was inversely associated with risk of high grade but not with overall risk of PC. Men consuming 3 or more cups of coffee per day experienced 55% lower risk of high Gleason grade disease compared with non-coffee drinkers in analysis adjusted for age and social class (HR 0.45, 95% CI 0.23-0.90, p value for trend 0.01). This association changed a little after additional adjustment for Body Mass Index, smoking, cholesterol level, systolic blood pressure, tea intake and alcohol consumption.</p> <p>Conclusion</p> <p>Coffee consumption reduces the risk of aggressive PC but not the overall risk.</p

    ciliaFA : a research tool for automated, high-throughput measurement of ciliary beat frequency using freely available software

    Get PDF
    Background: Analysis of ciliary function for assessment of patients suspected of primary ciliary dyskinesia (PCD) and for research studies of respiratory and ependymal cilia requires assessment of both ciliary beat pattern and beat frequency. While direct measurement of beat frequency from high-speed video recordings is the most accurate and reproducible technique it is extremely time consuming. The aim of this study was to develop a freely available automated method of ciliary beat frequency analysis from digital video (AVI) files that runs on open-source software (ImageJ) coupled to Microsoft Excel, and to validate this by comparison to the direct measuring high-speed video recordings of respiratory and ependymal cilia. These models allowed comparison to cilia beating between 3 and 52 Hz. Methods: Digital video files of motile ciliated ependymal (frequency range 34 to 52 Hz) and respiratory epithelial cells (frequency 3 to 18 Hz) were captured using a high-speed digital video recorder. To cover the range above between 18 and 37 Hz the frequency of ependymal cilia were slowed by the addition of the pneumococcal toxin pneumolysin. Measurements made directly by timing a given number of individual ciliary beat cycles were compared with those obtained using the automated ciliaFA system. Results: The overall mean difference (± SD) between the ciliaFA and direct measurement high-speed digital imaging methods was −0.05 ± 1.25 Hz, the correlation coefficient was shown to be 0.991 and the Bland-Altman limits of agreement were from −1.99 to 1.49 Hz for respiratory and from −2.55 to 3.25 Hz for ependymal cilia. Conclusions: A plugin for ImageJ was developed that extracts pixel intensities and performs fast Fourier transformation (FFT) using Microsoft Excel. The ciliaFA software allowed automated, high throughput measurement of respiratory and ependymal ciliary beat frequency (range 3 to 52 Hz) and avoids operator error due to selection bias. We have included free access to the ciliaFA plugin and installation instructions in Additional file 1 accompanying this manuscript that other researchers may use

    Photoemission core level binding energies from multiple sized nanoparticles on the same support: TiO₂(110)/Au

    Get PDF
    A novel method of measuring the core level binding energies of multiple sized nanoparticles on the same substrate is demonstrated using the early stage of Au nanoparticle growth on reduced r-TiO2(110). This method employed in situ scanning tunneling microscopy (STM) and microfocused X-ray photoemission spectroscopy. An STM tip-shadowing method was used to synthesize patterned areas of Au nanoparticles on the substrate with different coverages and sizes. Patterns were identified and imaged using a UV photoelectron emission microscope. The Au 4f core level binding energies of the nanoparticles were investigated as a function of Au nanoparticle coverage and size. A combination of initial and final state effects modifies the binding energies of the Au 4f core levels as the nanoparticle size changes. When single Au atoms and Au3 clusters are present, the Au 4f7/2 binding energy, 84.42 eV, is similar to that observed at a high coverage (1.8 monolayer equivalent), resulting from a cancellation of initial and final state effects. As the coverage is increased, there is a decrease in binding energy, which then increases at a higher coverage to 84.39 eV. These results are consistent with a Volmer-Weber nucleation-growth model of Au nanoparticles at oxygen vacancies, resulting in electron transfer to the nanoparticles

    A systematic review of the discriminating biomechanical parameters during the single leg squat

    Get PDF
    Objective: To determine whether there are common biomechanical parameters when analysing the single leg squat movement to compare pathological and non-pathological groups and whether these parameters are able to effectively distinguish between groups. Methods: Five electronic databases were searched using MESH terms, keywords and phrases across four constructs: squat, biomechanical measures, region of interest, study design. Studies were selected based on inclusion of a quantitative biomechanical measure, compared between a pathological and a non-pathological group, and participants performed a single leg squat movement. Results: Fifteen studies were included and reviewed, where the majority of studies investigated patellofemoral pain. There was considerable variation in the biomechanical outcome measure used to compare between groups. The frontal plane projection angle was the most commonly reported measure. There was considerable variation in the manner in which the single leg squat was performed. Conclusion: Due to variation in how the single leg squat was performed, it was not possible to determine specific biomechanical parameters that distinguish between pathological and non-pathological groups. Frontal plane projection angle appeared to be a parameter that could be effectively utilised. Standardisation of the single leg squat movement is needed to allow comparison between studies of pathological and non-pathological groups

    Parallelization of Kinetic Theory Simulations

    Full text link
    Numerical studies of shock waves in large scale systems via kinetic simulations with millions of particles are too computationally demanding to be processed in serial. In this work we focus on optimizing the parallel performance of a kinetic Monte Carlo code for astrophysical simulations such as core-collapse supernovae. Our goal is to attain a flexible program that scales well with the architecture of modern supercomputers. This approach requires a hybrid model of programming that combines a message passing interface (MPI) with a multithreading model (OpenMP) in C++. We report on our approach to implement the hybrid design into the kinetic code and show first results which demonstrate a significant gain in performance when many processors are applied.Comment: 10 pages, 3 figures, conference proceeding

    Gravitational Waves from Gravitational Collapse

    Get PDF
    Gravitational wave emission from the gravitational collapse of massive stars has been studied for more than three decades. Current state of the art numerical investigations of collapse include those that use progenitors with realistic angular momentum profiles, properly treat microphysics issues, account for general relativity, and examine non--axisymmetric effects in three dimensions. Such simulations predict that gravitational waves from various phenomena associated with gravitational collapse could be detectable with advanced ground--based and future space--based interferometric observatories.Comment: 68 pages including 13 figures; revised version accepted for publication in Living Reviews in Relativity (http://www.livingreviews.org

    Evaluation of a community pharmacy-led test-and-treat service for women with uncomplicated lower urinary tract infection in England

    Get PDF
    Background Uncomplicated lower urinary tract infections (UTIs) are common in women consulting primary healthcare, taking up GP resources. Delayed consultation can increase the risk of serious infections such as pyelonephritis or bacteraemia. Objectives To evaluate the effectiveness and uptake of a lower UTI test-and-treat service for women presenting with urinary symptoms within a community pharmacy in supporting self-care and appropriate use of antibiotics and reducing demand on other NHS resources. Methods The service was aligned to national guidelines to diagnose and treat lower UTI in women aged 16–64 years and used national resources to provide safety-netting and self-care advice. Consultation included clinical assessment and a urine dipstick test alongside a novel smartphone app, with diagnosis informed by test results. Women were provided with safety-netting advice and either advised on self-care, supplied with antibiotics or referred to their GP. Results Data were analysed for 764 women who presented to 23 pharmacies during December 2018 to April 2019. Lower UTI was found to be likely in 372/496 (75.0%) women, most of whom purchased antibiotics on the same day. Had the service not been available, approximately three-quarters of women who had completed the service and responded to the question would have visited their GP (214/301) and more than one-third would have used self-care with or without going to see their GP (116/301). Conclusions A community pharmacy-led UTI test-and-treat service for women aged 16–64 years presenting with urinary symptoms provided accessible and timely care aligned to national guidance, with 75.0% of consultations requiring antibiotic treatment
    corecore