209 research outputs found

    Chest radiography practice in critically ill patients: a postal survey in the Netherlands

    Get PDF
    BACKGROUND: To ascertain current chest radiography practice in intensive care units (ICUs) in the Netherlands. METHODS: Postal survey: a questionnaire was sent to all ICUs with > 5 beds suitable for mechanical ventilation; pediatric ICUs were excluded. When an ICU performed daily-routine chest radiographs in any group of patients it was considered to be a "daily-routine chest radiography" ICU. RESULTS: From the number of ICUs responding, 63% practice a daily-routine strategy, in which chest radiographs are obtained on a daily basis without any specific reason. A daily-routine chest radiography strategy is practiced less frequently in university-affiliated ICUs (50%) as compared to other ICUs (68%), as well as in larger ICUs (> 20 beds, 50%) as compared to smaller ICUs (< 20 beds, 65%) (P > 0.05). Remarkably, physicians that practice a daily-routine strategy consider daily-routine radiographs helpful in guiding daily practice in less than 30% of all performed radiographs. Chest radiographs are considered essential for verification of the position of invasive devices (81%) and for diagnosing pneumothorax, pneumonia or acute respiratory distress syndrome (82%, 74% and 69%, respectively). On demand chest radiographs are obtained after introduction of thoracic drains, central venous lines and endotracheal tubes in 98%, 84% and 75% of responding ICUs, respectively. Chest films are also obtained in case of ventilatory deterioration (49% of responding ICUs), and after cardiopulmonary resuscitation (59%), tracheotomy (58%) and mini-tracheotomy (23%). CONCLUSION: There is notable lack of consensus on chest radiography practice in the Netherlands. This survey suggests that a large number of intensivists may doubt the value of daily-routine chest radiography, but still practice a daily-routine strategy

    Sensitivity and specificity of lung cancer screening using chest low-dose computed tomography

    Get PDF
    Lung cancer screening programmes using chest X-ray and sputum cytology are routinely performed in Japan; however, the efficacy is insufficient. Screening using low-dose computed tomography (CT) is a more effective approach and has the potential to detect the disease more accurately. A total of 7183 low-dose CT screening tests for 4689 participants and 36 085 chest X-ray screening tests for 13 381 participants were conducted between August 1998 and May 2002. Sensitivity and specificity of lung cancer screening were calculated by both the detection method and the incidence method by linkage of the screening database and the Cancer Registry database. The preclinical detectable phase was assumed to be 1 year. Sensitivity and specificity by the detection method were 88.9 and 92.6% for low-dose CT and 78.3 and 97.0% for chest X-ray, respectively. Sensitivity of low-dose CT by the incidence method was 79.5%, whereas that of chest X-ray was 86.5%. Lung cancer screening using low-dose CT resulted in higher sensitivity and lower specificity than traditional screening according to the detection method. However, sensitivity by the incidence method was not as high as this. These findings demonstrate the potential for overdiagnosis in CT screening-detected cases

    Magnetic resonance imaging for lung cancer detection: Experience in a population of more than 10,000 healthy individuals

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Recent refinements of lung MRI techniques have reduced the examination time and improved diagnostic sensitivity and specificity. We conducted a study to assess the feasibility of MRI for the detection of primary lung cancer in asymptomatic individuals.</p> <p>Methods</p> <p>A retrospective chart review was performed on images of lung parenchyma, which were extracted from whole-body MRI examinations between October 2000 and December 2007. 11,766 consecutive healthy individuals (mean age, 50.4 years; 56.8% male) were scanned using one of two 1.5-T scanners (Sonata and Sonata Maestro, Siemens Medical Solutions, Erlangen, Germany). The standard protocol included a quick whole-lung survey with T2-weighted 2-dimensional half Fourier acquisition single shot turbo spin echo (HASTE) and 3-dimensional volumetric interpolated breath-hold examination (VIBE). Total examination time was less than 10 minutes, and scanning time was only 5 minutes. Prompt referrals and follow-ups were arranged in cases of suspicious lung nodules.</p> <p>Results</p> <p>A total of 559 individuals (4.8%) had suspicious lung nodules. A total of 49 primary lung cancers were diagnosed in 46 individuals: 41 prevalence cancers and 8 incidence cancers. The overall detection rate of primary lung cancers was 0.4%. For smokers aged 51 to 70 years, the detection rate was 1.4%. TNM stage I disease accounted for 37 (75.5%). The mean size of detected lung cancers was 1.98 cm (median, 1.5 cm; range, 0.5-8.2 cm). The most histological types were adenocarcinoma in 38 (77.6%).</p> <p>Conclusion</p> <p>Rapid zero-dose MRI can be used for lung cancer detection in a healthy population.</p

    BRISC—An Open Source Pulmonary Nodule Image Retrieval Framework

    Get PDF
    We have created a content-based image retrieval framework for computed tomography images of pulmonary nodules. When presented with a nodule image, the system retrieves images of similar nodules from a collection prepared by the Lung Image Database Consortium (LIDC). The system (1) extracts images of individual nodules from the LIDC collection based on LIDC expert annotations, (2) stores the extracted data in a flat XML database, (3) calculates a set of quantitative descriptors for each nodule that provide a high-level characterization of its texture, and (4) uses various measures to determine the similarity of two nodules and perform queries on a selected query nodule. Using our framework, we compared three feature extraction methods: Haralick co-occurrence, Gabor filters, and Markov random fields. Gabor and Markov descriptors perform better at retrieving similar nodules than do Haralick co-occurrence techniques, with best retrieval precisions in excess of 88%. Because the software we have developed and the reference images are both open source and publicly available they may be incorporated into both commercial and academic imaging workstations and extended by others in their research

    Thoracoscopic detection of occult indeterminate pulmonary nodules using bronchoscopic pleural dye marking

    Get PDF
    Background: The annual incidence of a small indeterminate pulmonary nodule (IPN) on computed tomography (CT) scan remains high. While traditional paradigms exist, the integration of new technologies into these diagnostic and treatment algorithms can result in alternative, potentially more efficient methods of managing these findings. Methods: We report on an alternative diagnostic and therapeutic strategy for the management of an IPN. This approach combines electromagnetic navigational bronchoscopy (ENB) with an updated approach to placement of a pleural dye marker. This technique lends itself to a minimally invasive wedge resection via either video-assisted thoracoscopic surgery (VATS) or a robotic approach. Results: Subsequent to alterations in the procedure, a cohort of 22 patients with an IPN was reviewed. Navigation was possible in 21 out of 22 patients with one patient excluded based on airway anatomy. The remaining 21 patients underwent ENB with pleural dye marking followed by minimally invasive wedge resection. The median size of the nodules was 13.4 mm (range: 7–29). There were no complications from the ENB procedure. Indigo carmine dye was used in ten patients. Methylene blue was used in the remaining 11 patients. In 81% of cases, the visceral pleural marker was visible at the time of surgery. In one patient, there was diffuse staining of the parietal pleura. In three additional patients, no dye was identified within the hemithorax. In all cases where dye marker was present on the visceral pleural surface, it was in proximity to the IPN and part of the excised specimen. Conclusions: ENB with pleural dye marking can provide a safe and effective method to localize an IPN and can allow for subsequent minimally invasive resection. Depending on the characteristics and location of the nodule, this method may allow more rapid identification intraoperatively

    CT Scan Screening for Lung Cancer: Risk Factors for Nodules and Malignancy in a High-Risk Urban Cohort

    Get PDF
    Low-dose computed tomography (CT) for lung cancer screening can reduce lung cancer mortality. The National Lung Screening Trial reported a 20% reduction in lung cancer mortality in high-risk smokers. However, CT scanning is extremely sensitive and detects non-calcified nodules (NCNs) in 24-50% of subjects, suggesting an unacceptably high false-positive rate. We hypothesized that by reviewing demographic, clinical and nodule characteristics, we could identify risk factors associated with the presence of nodules on screening CT, and with the probability that a NCN was malignant.We performed a longitudinal lung cancer biomarker discovery trial (NYU LCBC) that included low-dose CT-screening of high-risk individuals over 50 years of age, with more than 20 pack-year smoking histories, living in an urban setting, and with a potential for asbestos exposure. We used case-control studies to identify risk factors associated with the presence of nodules (n=625) versus no nodules (n=557), and lung cancer patients (n=30) versus benign nodules (n=128).The NYU LCBC followed 1182 study subjects prospectively over a 10-year period. We found 52% to have NCNs >4 mm on their baseline screen. Most of the nodules were stable, and 9.7% of solid and 26.2% of sub-solid nodules resolved. We diagnosed 30 lung cancers, 26 stage I. Three patients had synchronous primary lung cancers or multifocal disease. Thus, there were 33 lung cancers: 10 incident, and 23 prevalent. A sub-group of the prevalent group were stable for a prolonged period prior to diagnosis. These were all stage I at diagnosis and 12/13 were adenocarcinomas.NCNs are common among CT-screened high-risk subjects and can often be managed conservatively. Risk factors for malignancy included increasing age, size and number of nodules, reduced FEV1 and FVC, and increased pack-years smoking. A sub-group of screen-detected cancers are slow-growing and may contribute to over-diagnosis and lead-time biases

    An evaluation of screening for lung cancer in Niigata Prefecture, Japan: a population-based case–control study

    Get PDF
    Although an annual screening programme for lung cancer has been carried out widely in Japan since 1987, there is insufficient evidence to confirm its efficacy in terms of reducing mortality. In order to evaluate the efficacy of the lung cancer screening which has been widely carried out in Japan since 1987, a case–control study was conducted in Niigata Prefecture, Japan. In the study area, chest X-ray examinations for all participants and sputum cytology for high-risk participants were offered annually. Case subjects, who had died from lung cancer (174), and control subjects matched by sex, year of birth, residence and smoking status (801), who had been alive at the time of diagnosis of the corresponding case, were selected from the National Health Insurance holders. Screening histories of the subjects were compared between cases and matched controls for the identical calendar period before the time of diagnosis of the cases. The odds ratio of death from lung cancer for those screened within 12 months vs those not screened was 0.401 (95% CI: 0.272–0.591) with adjustment by smoking index. Our results suggest that annual lung cancer screening might reduce mortality from lung cancer by approximately 60%. © 2001 Cancer Research Campaig