474 research outputs found

    Performance of Monolayer Graphene Nanomechanical Resonators with Electrical Readout

    Full text link
    The enormous stiffness and low density of graphene make it an ideal material for nanoelectromechanical (NEMS) applications. We demonstrate fabrication and electrical readout of monolayer graphene resonators, and test their response to changes in mass and temperature. The devices show resonances in the MHz range. The strong dependence of the resonant frequency on applied gate voltage can be fit to a membrane model, which yields the mass density and built-in strain. Upon removal and addition of mass, we observe changes in both the density and the strain, indicating that adsorbates impart tension to the graphene. Upon cooling, the frequency increases; the shift rate can be used to measure the unusual negative thermal expansion coefficient of graphene. The quality factor increases with decreasing temperature, reaching ~10,000 at 5 K. By establishing many of the basic attributes of monolayer graphene resonators, these studies lay the groundwork for applications, including high-sensitivity mass detectors

    A Corpus of Potentially Contradictory Research Claims from Cardiovascular Research Abstracts

    Get PDF
    Background: Research literature in biomedicine and related fields contains a huge number of claims, such as the effectiveness of treatments. These claims are not always consistent and may even contradict each other. Being able to identify contradictory claims is important for those who rely on the biomedical literature. Automated methods to identify and resolve them are required to cope with the amount of information available. However, research in this area has been hampered by a lack of suitable resources. We describe a methodology to develop a corpus which addresses this gap by providing examples of potentially contradictory claims and demonstrate how it can be applied to identify these claims from Medline abstracts related to the topic of cardiovascular disease. Methods A set of systematic reviews concerned with four topics in cardiovascular disease were identified from Medline and analysed to determine whether the abstracts they reviewed contained contradictory research claims. For each review, annotators were asked to analyse these abstracts to identify claims within them that answered the question addressed in the review. The annotators were also asked to indicate how the claim related to that question and the type of the claim. Results: A total of 259 abstracts associated with 24 systematic reviews were used to form the corpus. Agreement between the annotators was high, suggesting that the information they provided is reliable. Conclusions: The paper describes a methodology for constructing a corpus containing contradictory research claims from the biomedical literature. The corpus is made available to enable further research into this area and support the development of automated approaches to contradiction identification

    Effect of promoter architecture on the cell-to-cell variability in gene expression

    Get PDF
    According to recent experimental evidence, the architecture of a promoter, defined as the number, strength and regulatory role of the operators that control the promoter, plays a major role in determining the level of cell-to-cell variability in gene expression. These quantitative experiments call for a corresponding modeling effort that addresses the question of how changes in promoter architecture affect noise in gene expression in a systematic rather than case-by-case fashion. In this article, we make such a systematic investigation, based on a simple microscopic model of gene regulation that incorporates stochastic effects. In particular, we show how operator strength and operator multiplicity affect this variability. We examine different modes of transcription factor binding to complex promoters (cooperative, independent, simultaneous) and how each of these affects the level of variability in transcription product from cell-to-cell. We propose that direct comparison between in vivo single-cell experiments and theoretical predictions for the moments of the probability distribution of mRNA number per cell can discriminate between different kinetic models of gene regulation.Comment: 35 pages, 6 figures, Submitte

    Graphene Photonics and Optoelectronics

    Full text link
    The richness of optical and electronic properties of graphene attracts enormous interest. Graphene has high mobility and optical transparency, in addition to flexibility, robustness and environmental stability. So far, the main focus has been on fundamental physics and electronic devices. However, we believe its true potential to be in photonics and optoelectronics, where the combination of its unique optical and electronic properties can be fully exploited, even in the absence of a bandgap, and the linear dispersion of the Dirac electrons enables ultra-wide-band tunability. The rise of graphene in photonics and optoelectronics is shown by several recent results, ranging from solar cells and light emitting devices, to touch screens, photodetectors and ultrafast lasers. Here we review the state of the art in this emerging field.Comment: Review Nature Photonics, in pres

    Human behaviour in emergency situations: comparisons between aviation and rail domains

    Get PDF
    This article presents a comparative review of the knowledge base regarding human behaviour in emergencies for both aviation and rail domains. Generic models of human behaviour in emergency situations are introduced and specific attention is then focussed on methods of behaviour prediction, exhibited behaviours in emergencies and methods of aiding evacuation across both modes of transport. Using established knowledge from the aviation domain, it has been possible to make observations and comparisons about the rail domain. Traditionally, the aviation domain has been a major focus of research attention and this is used to inform and interpret the rail domain. By drawing comparisons across these domains for human behaviour in emergency situations, the observations are discussed along with recommendations for future policies/planning for emergencies and future research areas

    Search for sterile neutrino mixing in the MINOS long-baseline experiment

    Get PDF
    A search for depletion of the combined flux of active neutrino species over a 735 km baseline is reported using neutral-current interaction data recorded by the MINOS detectors in the NuMI neutrino beam. Such a depletion is not expected according to conventional interpretations of neutrino oscillation data involving the three known neutrino flavors. A depletion would be a signature of oscillations or decay to postulated noninteracting sterile neutrinos, scenarios not ruled out by existing data. From an exposure of 3.18×1020 protons on target in which neutrinos of energies between ~500¿¿MeV and 120 GeV are produced predominantly as ¿µ, the visible energy spectrum of candidate neutral-current reactions in the MINOS far detector is reconstructed. Comparison of this spectrum to that inferred from a similarly selected near-detector sample shows that of the portion of the ¿µ flux observed to disappear in charged-current interaction data, the fraction that could be converting to a sterile state is less than 52% at 90% confidence level (C.L.). The hypothesis that active neutrinos mix with a single sterile neutrino via oscillations is tested by fitting the data to various models. In the particular four-neutrino models considered, the mixing angles ¿24 and ¿34 are constrained to be less than 11° and 56° at 90% C.L., respectively. The possibility that active neutrinos may decay to sterile neutrinos is also investigated. Pure neutrino decay without oscillations is ruled out at 5.4 standard deviations. For the scenario in which active neutrinos decay into sterile states concurrently with neutrino oscillations, a lower limit is established for the neutrino decay lifetime t3/m3>2.1×10-12¿¿s/eV at 90% C.L

    Achieving Secondary Prevention Low-Density Lipoprotein Particle Concentration Goals Using Lipoprotein Cholesterol-Based Data

    Get PDF
    BACKGROUND: Epidemiologic studies suggest that LDL particle concentration (LDL-P) may remain elevated at guideline recommended LDL cholesterol goals, representing a source of residual risk. We examined the following seven separate lipid parameters in achieving the LDL-P goal of <1000 nmol/L goal for very high risk secondary prevention: total cholesterol to HDL cholesterol ratio, TC/HDL, <3; a composite of ATP-III very high risk targets, LDL-C<70 mg/dL, non-HDL-C<100 mg/dL and TG<150 mg/dL; a composite of standard secondary risk targets, LDL-C<100, non-HDL-C<130, TG<150; LDL phenotype; HDL-C ≥ 40; TG<150; and TG/HDL-C<3. METHODS: We measured ApoB, ApoAI, ultracentrifugation lipoprotein cholesterol and NMR lipoprotein particle concentration in 148 unselected primary and secondary prevention patients. RESULTS: TC/HDL-C<3 effectively discriminated subjects by LDL-P goal (F = 84.1, p<10(-6)). The ATP-III very high risk composite target (LDL-C<70, nonHDL-C<100, TG<150) was also effective (F = 42.8, p<10(-5)). However, the standard secondary prevention composite (LDL-C<100, non-HDL-C<130, TG<150) was also effective but yielded higher LDL-P than the very high risk composite (F = 42.0, p<10(-5)) with upper 95% confidence interval of LDL-P less than 1000 nmol/L. TG<150 and TG/HDL-C<3 cutpoints both significantly discriminated subjects but the LDL-P upper 95% confidence intervals fell above goal of 1000 nmol/L (F = 15.8, p = 0.0001 and F = 9.7, p = 0.002 respectively). LDL density phenotype neared significance (F = 2.85, p = 0.094) and the HDL-C cutpoint of 40 mg/dL did not discriminate (F = 0.53, p = 0.47) alone or add discriminatory power to ATP-III targets. CONCLUSIONS: A simple composite of ATP-III very high risk lipoprotein cholesterol based treatment targets or TC/HDL-C ratio <3 most effectively identified subjects meeting the secondary prevention target level of LDL-P<1000 nmol/L, providing a potential alternative to advanced lipid testing in many clinical circumstances

    Noise Reduction by Diffusional Dissipation in a Minimal Quorum Sensing Motif

    Get PDF
    Cellular interactions are subject to random fluctuations (noise) in quantities of interacting molecules. Noise presents a major challenge for the robust function of natural and engineered cellular networks. Past studies have analyzed how noise is regulated at the intracellular level. Cell–cell communication, however, may provide a complementary strategy to achieve robust gene expression by enabling the coupling of a cell with its environment and other cells. To gain insight into this issue, we have examined noise regulation by quorum sensing (QS), a mechanism by which many bacteria communicate through production and sensing of small diffusible signals. Using a stochastic model, we analyze a minimal QS motif in Gram-negative bacteria. Our analysis shows that diffusion of the QS signal, together with fast turnover of its transcriptional regulator, attenuates low-frequency components of extrinsic noise. We term this unique mechanism “diffusional dissipation” to emphasize the importance of fast signal turnover (or dissipation) by diffusion. We further show that this noise attenuation is a property of a more generic regulatory motif, of which QS is an implementation. Our results suggest that, in a QS system, an unstable transcriptional regulator may be favored for regulating expression of costly proteins that generate public goods
    corecore