34 research outputs found

    The validation of a new measure quantifying the social quality of life of ethnically diverse older women: two cross-sectional studies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>To our knowledge, the available psychometric literature does not include an instrument for the quantification of social quality of life among older women from diverse ethnic backgrounds. To address the need for a tool of this kind, we conducted two studies to assess the initial reliability and validity of a new instrument. The latter was created specifically to quantify the contribution of a) social networks and resources (e.g., family, friends, and community) as well as b) one's perceived power and respect within family and community to subjective well-being in non-clinical, ethnically diverse populations of older women.</p> <p>Methods</p> <p>In Study 1, we recruited a cross-sectional sample of primarily non-European-American older women (<it>N </it>= 220) at a variety of community locations. Participants were administered the following: a short screener for dementia; a demographic list; an initial pool of 50 items from which the final items of the new Older Women's Social Quality of Life Inventory (OWSQLI) were to be chosen (based on a statistical criterion to apply to the factor analysis findings); the Single Item Measure of Social Support (SIMSS); and the Medical Outcome Study 36-item Short-Form Health Survey (MOS SF-36). Study 2 was conducted on a second independent sample of ethnically diverse older women. The same recruitment strategies, procedures, and instruments as those of Study 1 were utilized in Study 2, whose sample was comprised of 241 older women with mostly non-European-American ethnic status.</p> <p>Results</p> <p>In Study 1, exploratory factor analysis of the OWSQLI obtained robust findings: the total variance explained by one single factor with the final selection of 22 items was over 44%. The OWSQLI demonstrated strong internal consistency (<it>α </it>= .92, <it>p </it>< .001), adequate criterion validity with the SIMSS (<it>r </it>= .33; <it>p </it>< .01), and (as expected) moderate concurrent validity with the MOS SF-36 for both physical (<it>r </it>= .21; <it>p </it>< .01) and mental (<it>r </it>= .26; <it>p </it>< .01) quality of life. In order to confirm the validity of the 22-item OWSQLI scale that emerged from Study 1 analyses, we replicated those analyses in Study 2, although using confirmatory factor analysis. The total variance accounted for by one factor was about 42%, again quite high and indicative of a strong single-factor solution. Study 2 data analyses yielded the same strong reliability findings (i.e., <it>α </it>= .92, <it>p </it>< .001). The 22-item OWSQLI was correlated with the SIMSS (<it>r </it>= .27, <it>p </it>< .001) in the expected direction. Finally, correlations with the MOS SF- 36 demonstrated moderate concurrent validity for physical (<it>r </it>= .14; <it>p </it>< .01) and mental (<it>r </it>= .18; <it>p </it>< .01) quality of life, as expected.</p> <p>Conclusions</p> <p>The findings of these two studies highlight the potential for our new tool to provide a valid measure of older women's social quality of life, yet they require duplication in longitudinal research. Interested clinicians should consider using the OWSQLI in their assessment battery to identify older women's areas of lower versus higher social quality of life, and should establish the maximization of patients' social quality of life as an important therapeutic goal, as this variable is significantly related to both physical and mental health.</p

    Overview of the VA Quality Enhancement Research Initiative (QUERI) and QUERI theme articles: QUERI Series

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Continuing challenges to timely adoption of evidence-based clinical practices in healthcare have generated intense interest in the development and application of new implementation methods and frameworks. These challenges led the United States (U.S.) Department of Veterans Affairs (VA) to create the Quality Enhancement Research Initiative (QUERI) in the late 1990s. QUERI's purpose was to harness VA's health services research expertise and resources in an ongoing system-wide effort to improve the performance of the VA healthcare system and, thus, quality of care for veterans. QUERI in turn created a systematic means of involving VA researchers both in enhancing VA healthcare quality, by implementing evidence-based practices, and in contributing to the continuing development of implementation science.</p> <p>The efforts of VA researchers to improve healthcare delivery practices through QUERI and related initiatives are documented in a growing body of literature. The scientific frameworks and methodological approaches developed and employed by QUERI are less well described. A QUERI Series of articles in <it>Implementation Science </it>will illustrate many of these QUERI tools. This <it>Overview </it>article introduces both QUERI and the Series.</p> <p>Methods</p> <p>The <it>Overview </it>briefly explains the purpose and context of the QUERI Program. It then describes the following: the key operational structure of QUERI Centers, guiding frameworks designed to enhance implementation and related research, QUERI's progress and promise to date, and the Series' general content. QUERI's frameworks include a core set of steps for diagnosing and closing quality gaps and, simultaneously, advancing implementation science. Throughout the paper, the envisioned involvement and activities of VA researchers within QUERI Centers also are highlighted. The Series is then described, illustrating the use of QUERI frameworks and other tools designed to respond to implementation challenges.</p> <p>Conclusion</p> <p>QUERI's simultaneous pursuit of improvement and research goals within a large healthcare system may be unique. However, descriptions of this still-evolving effort, including its conceptual frameworks, methodological approaches, and enabling processes, should have applicability to implementation researchers in a range of health care settings. Thus, the <it>Series </it>is offered as a resource for other implementation research programs and researchers pursuing common goals in improving care and developing the field of implementation science.</p

    The physical and mental health of a large military cohort: baseline functional health status of the Millennium Cohort

    Get PDF
    <p>Abstract</p> <p>Background:</p> <p>The US military is currently involved in large, lengthy, and complex combat operations around the world. Effective military operations require optimal health of deployed service members, and both mental and physical health can be affected by military operations.</p> <p>Methods:</p> <p>Baseline data were collected from 77,047 US service members during 2001–2003 as part of a large, longitudinal, population-based military health study (the Millennium Cohort Study). The authors calculated unadjusted, adjusted, and weighted means for the Medical Outcomes Study Short Form 36-item Survey for Veterans physical (PCS) and mental component summary (MCS) scores over a variety of demographic and military characteristics at baseline.</p> <p>Results:</p> <p>The unadjusted mean PCS and MCS scores for this study were 53.4 (95% confidence interval: 53.3–53.4) and 52.8 (95% confidence interval: 52.7–52.9). Average PCS and MCS scores were slightly more favorable in this military sample compared to those of the US general population of the same age and sex. Factors independently associated with more favorable health status included male gender, being married, higher educational attainment, higher military rank, and Air Force service. Combat specialists had similar health status compared to other military occupations. Having been deployed to Southwest Asia, Bosnia, or Kosovo between 1998 and 2000 was not associated with diminished health status.</p> <p>Conclusion:</p> <p>The baseline health status of this large population-based military cohort is better than that of the US general population of the same age and sex distribution over the same time period, especially in older age groups. Deployment experiences during the period of 1998–2001 were not associated with decreased health status. These data will serve as a useful reference for other military health studies and for future longitudinal analyses.</p

    A comparison of 4D time-resolved MRA with keyhole and 3D time-of-flight MRA at 3.0 T for the evaluation of cerebral aneurysms

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>A subarachnoid hemorrhage (SAH) due to the rupture of a cerebral aneurysm (CA) is a devastating event associated with high rates of mortality. Magnetic resonance angiography (MRA), as a noninvasive technique, is typically used initially. The object of our study is to evaluate the feasibility of 4D time-resolved MRA with keyhole (4D-TRAK) for the diagnostic accuracy and reliability of the detection and characterization of cerebral aneurysms (CAs), with a comparison of 3D time-of-flight MRA (3D-TOF-MRA) by using DSA as a reference.</p> <p>Methods</p> <p>3D-TOF-MRA, 4D-TRAK and 3D-DSA were performed sequentially in 52 patients with suspected CAs. 4D-TRAK was acquired using a combination of sensitivity encoding (SENSE) and CE timing robust angiography (CENTRA) k-space sampling techniques at a contrast dose of 10 ml at 3 T. Accuracy, sensitivity, specificity of 4D-TRAK and 3D-TOF-MRA were calculated and compared for the detection of CAs on patient-based and aneurysm-based evaluation using 3D-DSA as a reference.</p> <p>Results</p> <p>The overall image quality of 4D-TRAK with a contrast dose of 10 ml was in the diagnostic range but still cannot be compared with that of 3D-TOF-MRA. In 52 patients with suspected CAs, fifty-eight CAs were confirmed on 3D-DSA finally. Fifty-one (with 2 false-positives and 9 false-negatives) and 58 (with 1 false-positive and 1 false-negative) CAs were visualized on 4D-TRAK and 3D-TOF-MRA, respectively. Accuracy, sensitivity and specificity on patient-based evaluation of 4D-TRAK and 3D-TOF-MRA were 92.31%, 93.33%, 85.71% and 98.08%, 100%, 85.71%, respectively, and 74.07%, 75.00%, 66.67% and 96.30%, 95.83%, 100% on aneurysm-based evaluation in patients with multiple CAs, respectively. Subgroup analysis revealed that for 19 very small CAs (maximal diameter <3 mm, measured on 3D-DSA), 9 were missed on 4D-TRAK and 1 on 3D-TOF-MRA (P = 0.008). However, for 39 CAs with maximal diameter ≥ 3 mm, the diagnostic accuracy is equally (39 on 4D-TRAK vs. 39 on 3D-TOF-MRA) (P = 1). In four larger CAs with maximal diameter ≥ 10 mm, 4D-TRAK provided a better characterization of morphology than 3D-TOF-MRA.</p> <p>Conclusion</p> <p>4D-TRAK at a lower contrast dose of 10 ml with a combination of SENSE and CENTRA at 3 T could provide similar diagnostic accuracy rate for CAs with maximal diameter ≥ 3 mm, and a better characterization of morphology for larger CAs with maximal diameter ≥ 10 mm compared to 3D-TOF-MRA. However, further study is still needed to improve the “vascular edge” artifact and the compromise in spatial resolution in depiction of CAs with maximal diameter<3 mm.</p
    corecore