1,943 research outputs found
A Prototype System for Measuring Microwave Frequency Reflections from the Breast
Microwave imaging of the breast is of interest for monitoring breast health, and approaches to active microwave imaging include tomography and radar-based methods. While the literature contains a growing body of work related to microwave breast imaging, there are only a few prototype systems that have been used to collect data from humans. In this paper, a prototype system for monostatic radar-based imaging that has been used in an initial study measuring reflections from volunteers is discussed. The performance of the system is explored by examining the mechanical positioning of sensor, as well as microwave measurement sensitivity. To gain insight into the measurement of reflected signals, simulations and measurements of a simple phantom are compared and discussed in relation to system sensitivity. Finally, a successful scan of a volunteer is described
Fluctuations in viscous fingering
Our experiments on viscous (Saffman-Taylor) fingering in Hele-Shaw channels
reveal finger width fluctuations that were not observed in previous
experiments, which had lower aspect ratios and higher capillary numbers Ca.
These fluctuations intermittently narrow the finger from its expected width.
The magnitude of these fluctuations is described by a power law, Ca^{-0.64},
which holds for all aspect ratios studied up to the onset of tip instabilities.
Further, for large aspect ratios, the mean finger width exhibits a maximum as
Ca is decreased instead of the predicted monotonic increase.Comment: Revised introduction, smoothed transitions in paper body, and added a
few additional minor results. (Figures unchanged.) 4 pages, 3 figures.
Submitted to PRE Rapi
Centrifugation and capillarity integrated into a multiple analyte whole blood analyser
A unique clinical chemistry analyser is described which processes
90 μl of whole blood (fingerstick or venous) into multiple aliquots of diluted plasma and reports the results of 12 tests in 14 min. To perform a panel of tests, the operator applies the unmetered sample directly into a single use, 8 cm diameter plastic rotor which contains the required liquid diluent and dry reagents. Using centrifugal and capillary forces, the rotor meters the required amount of blood, separates the red cells, meters the plasma, meters the diluent, mixes the fluids, distributes the fluid to the reaction cuvettes and mixes the reagents and the diluted plasma in the cuvettes. The instrument monitors the reagent reactions simultaneously using nine wavelengths, calculates the results from the absorbance data, and reports the results
Comment on "Nucleon elastic form factors and local duality"
We comment on the papers "Nucleon elastic form factors and local duality"
[Phys. Rev. {\bf D62}, 073008 (2000)] and "Experimental verification of
quark-hadron duality" [Phys. Rev. Lett. {\bf 85}, 1186 (2000)]. Our main
comment is that the reconstruction of the proton magnetic form factor, claimed
to be obtained from the inelastic scaling curve thanks to parton-hadron local
duality, is affected by an artifact.Comment: to appear in Phys. Rev.
Electromagnetic proton form factors in large QCD
The electromagnetic form factors of the proton are obtained using a
particular realization of QCD in the large limit (),
which sums up the infinite number of zero-width resonances to yield an Euler's
Beta function (Dual-). The form factors and
, as well as agree very well with reanalyzed space-like
data in the whole range of momentum transfer. In addition, the predicted ratio
is in good agreement with recent polarization transfer
measurements at Jefferson Lab.Comment: 10 page
Systematic review of context-aware digital behavior change interventions to improve health
Health risk behaviors are leading contributors to morbidity, premature mortality associated with chronic diseases, and escalating health costs. However, traditional interventions to change health behaviors often have modest effects, and limited applicability and scale. To better support health improvement goals across the care continuum, new approaches incorporating various smart technologies are being utilized to create more individualized digital behavior change interventions (DBCIs). The purpose of this study is to identify context-aware DBCIs that provide individualized interventions to improve health. A systematic review of published literature (2013-2020) was conducted from multiple databases and manual searches. All included DBCIs were context-aware, automated digital health technologies, whereby user input, activity, or location influenced the intervention. Included studies addressed explicit health behaviors and reported data of behavior change outcomes. Data extracted from studies included study design, type of intervention, including its functions and technologies used, behavior change techniques, and target health behavior and outcomes data. Thirty-three articles were included, comprising mobile health (mHealth) applications, Internet of Things wearables/sensors, and internet-based web applications. The most frequently adopted behavior change techniques were in the groupings of feedback and monitoring, shaping knowledge, associations, and goals and planning. Technologies used to apply these in a context-aware, automated fashion included analytic and artificial intelligence (e.g., machine learning and symbolic reasoning) methods requiring various degrees of access to data. Studies demonstrated improvements in physical activity, dietary behaviors, medication adherence, and sun protection practices. Context-aware DBCIs effectively supported behavior change to improve users' health behaviors
Radiative Corrections to Electron-Proton Scattering
The radiative corrections to elastic electron-proton scattering are analyzed
in a hadronic model including the finite size of the nucleon. For initial
electron energies above 8 GeV and large scattering angles, the proton vertex
correction in this model increases by at least two percent the overall factor
by which the one-photon exchange (Rosenbluth) cross section must be multiplied.
The contribution of soft photon emission is calculated exactly. Comparison is
made with the generally used expressions previously obtained by Mo and Tsai.
Results are presented for some kinematics at high momentum transfer.Comment: 31 pages, 4 figure
Hematological Changes in Women and Infants Exposed to an AZT-Containing Regimen for Prevention of Mother-to-child-transmission of HIV in Tanzania.
Tanzanian guidelines for prevention of mother-to-child-transmission of HIV (PMTCT) recommend an antiretroviral combination regimen involving zidovudine (AZT) during pregnancy, single-dosed nevirapine at labor onset, AZT plus Lamivudine (3TC) during delivery, and AZT/3TC for 1-4 weeks postpartum. As drug toxicities are a relevant concern, we assessed hematological alterations in AZT-exposed women and their infants. A cohort of HIV-positive women, either with AZT intake (n = 82, group 1) or without AZT intake (n = 62, group 2) for PMTCT during pregnancy, was established at Kyela District Hospital, Tanzania. The cohort also included the infants of group 1 with an in-utero AZT exposure ≥4 weeks, receiving AZT for 1 week postpartum (n = 41), and infants of group 2 without in-utero AZT exposure, receiving a prolonged 4-week AZT tail (n = 58). Complete blood counts were evaluated during pregnancy, birth, weeks 4-6 and 12. For women of group 1 with antenatal AZT intake, we found a statistically significant decrease in hemoglobin level, red blood cells, white blood cells, granulocytes, as well as an increase in red cell distribution width and platelet count. At delivery, the median red blood cell count was significantly lower and the median platelet count was significantly higher in women of group 1 compared to group 2. At birth, infants from group 1 showed a lower median hemoglobin level and granulocyte count and a higher frequency of anemia and granulocytopenia. At 4-6 weeks postpartum, the mean neutrophil granulocyte count was significantly lower and neutropenia was significantly more frequent in infants of group 2. AZT exposure during pregnancy as well as after birth resulted in significant hematological alterations for women and their newborns, although these changes were mostly mild and transient in nature. Research involving larger cohorts is needed to further analyze the impact of AZT-containing regimens on maternal and infant health
- …