3,389 research outputs found
Scattering a pulse from a chaotic cavity: Transitioning from algebraic to exponential decay
The ensemble averaged power scattered in and out of lossless chaotic cavities
decays as a power law in time for large times. In the case of a pulse with a
finite duration, the power scattered from a single realization of a cavity
closely tracks the power law ensemble decay initially, but eventually
transitions to an exponential decay. In this paper, we explore the nature of
this transition in the case of coupling to a single port. We find that for a
given pulse shape, the properties of the transition are universal if time is
properly normalized. We define the crossover time to be the time at which the
deviations from the mean of the reflected power in individual realizations
become comparable to the mean reflected power. We demonstrate numerically that,
for randomly chosen cavity realizations and given pulse shapes, the probability
distribution function of reflected power depends only on time, normalized to
this crossover time.Comment: 23 pages, 5 figure
Hammerhead, an ultrahigh resolution ePix camera for wavelength-dispersive spectrometers
Wavelength-dispersive spectrometers (WDS) are often used in synchrotron and
FEL applications where high energy resolution (in the order of eV) is
important. Increasing WDS energy resolution requires increasing spatial
resolution of the detectors in the dispersion direction. The common approaches
with strip detectors or small pixel detectors are not ideal. We present a novel
approach, with a sensor using rectangular pixels with a high aspect ratio
(between strips and pixels, further called "strixels"), and strixel
redistribution to match the square pixel arrays of typical ASICs while avoiding
the considerable effort of redesigning ASICs. This results in a sensor area of
17.4 mm x 77 mm, with a fine pitch of 25 m in the horizontal direction
resulting in 3072 columns and 176 rows. The sensors use ePix100 readout ASICs,
leveraging their low noise (43 e, or 180 eV rms). We present results
obtained with a Hammerhead ePix100 camera, showing that the small pitch (25
m) in the dispersion direction maximizes performance for both high and low
photon occupancies, resulting in optimal WDS energy resolution. The low noise
level at high photon occupancy allows precise photon counting, while at low
occupancy, both the energy and the subpixel position can be reconstructed for
every photon, allowing an ultrahigh resolution (in the order of 1 m) in
the dispersion direction and rejection of scattered beam and harmonics. Using
strixel sensors with redistribution and flip-chip bonding to standard ePix
readout ASICs results in ultrahigh position resolution (1 m) and low
noise in WDS applications, leveraging the advantages of hybrid pixel detectors
(high production yield, good availability, relatively inexpensive) while
minimizing development complexity through sharing the ASIC, hardware, software
and DAQ development with existing versions of ePix cameras.Comment: 8 pages, 6 figure
Ram-pressure stripped molecular gas in the Virgo spiral galaxy NGC 4522
IRAM 30m 12CO(1-0) and 12CO(2-1) HERA observations are presented for the
ram-pressure stripped Virgo spiral galaxy NGC 4522. The CO emission is detected
in the galactic disk and the extraplanar gas. The extraplanar CO emission
follows the morphology of the atomic gas closely but is less extended. The CO
maxima do not appear to correspond to regions where there is peak massive star
formation as probed by Halpha emission. The presence of molecular gas is a
necessary but not sufficient condition for star formation. Compared to the disk
gas, the molecular fraction of the extraplanar gas is 30% lower and the star
formation efficiency of the extraplanar gas is about 3 times lower. The
comparison with an existing dynamical model extended by a recipe for
distinguishing between atomic and molecular gas shows that a significant part
of the gas is stripped in the form of overdense arm-like structures. It is
argued that the molecular fraction depends on the square root of the total
large-scale density. Based on the combination of the CO/Halpha and an
analytical model, the total gas density is estimated to be about 4 times lower
than that of the galactic disk. Molecules and stars form within this dense gas
according to the same laws as in the galactic disk, i.e. they mainly depend on
the total large-scale gas density. Star formation proceeds where the local
large-scale gas density is highest. Given the complex 3D morphology this does
not correspond to the peaks in the surface density. In the absence of a
confining gravitational potential, the stripped gas arms will most probably
disperse; i.e. the density of the gas will decrease and star formation will
cease.Comment: 11 pages, 15 figures, A&A accepted for publicatio
Coexisting Angiomyolipoma and Renal Cell Carcinoma in a Kidney of an Elderly Woman: Case Report and Review of the Literature
Angiomyolipoma is a well described but relatively uncommon benign renal neoplasm composed of varying admixtures of mature adipose tissue, smooth muscle, and thick-walled blood vessels.[1] The incidence of angiomyolipoma is about 0.3% overall.[2] It frequently occurs in patients with tuberous sclerosis. Even more uncommon is the simultaneous occurrence of angiomyolipoma and renal cell cancer in the same kidney in a patient without tuberous sclerosis
Parallel suppression of superconductivity and Fe moment in the collapsed tetragonal phase of Ca0.67Sr0.33Fe2As2 under pressure
Using non-resonant Fe K-beta x-ray emission spectroscopy, we reveal that
Sr-doping of CaFe2As2 decouples the Fe moment from the volume collapse
transition, yielding a collapsed-tetragonal, paramagnetic normal state out of
which superconductivity develops. X-ray diffraction measurements implicate the
c-axis lattice parameter as the controlling criterion for the Fe moment,
promoting a generic description for the appearance of pressure-induced
superconductivity in the alkaline-earth-based 122 ferropnictides (AFe2As2). The
evolution of the superconducting critical temperature with pressure lends
support to theories for superconductivity involving unconventional pairing
mediated by magnetic fluctuations
Test beam Characterizations of 3D Silicon Pixel detectors
3D silicon detectors are characterized by cylindrical electrodes
perpendicular to the surface and penetrating into the bulk material in contrast
to standard Si detectors with planar electrodes on its top and bottom. This
geometry renders them particularly interesting to be used in environments where
standard silicon detectors have limitations, such as for example the radiation
environment expected in an LHC upgrade. For the first time, several 3D sensors
were assembled as hybrid pixel detectors using the ATLAS-pixel front-end chip
and readout electronics. Devices with different electrode configurations have
been characterized in a 100 GeV pion beam at the CERN SPS. Here we report
results on unirradiated devices with three 3D electrodes per 50 x 400 um2 pixel
area. Full charge collection is obtained already with comparatively low bias
voltages around 10 V. Spatial resolution with binary readout is obtained as
expected from the cell dimensions. Efficiencies of 95.9% +- 0.1 % for tracks
parallel to the electrodes and of 99.9% +- 0.1 % at 15 degrees are measured.
The homogeneity of the efficiency over the pixel area and charge sharing are
characterized.Comment: 5 pages, 7 figure
AART-BC: a sensor system for monitoring Assistive Technology use beyond the clinic
A wide range of assistive and rehabilitative technologies (ART) are available to assist with mobility and upper limb function. However, anecdotal evidence suggests many of the devices prescribed, or purchased, are either poorly used, or rejected entirely. This situation is costly, both for the healthcare provider and the user, and may be leading to secondary consequences, such as falls and/or social isolation. This paper reports on the development and initial feasibility testing of a system for monitoring when and how assistive devices are used outside of the clinic setting, and feeding this information to the device user themselves and/or prescribing clinician (where appropriate). Illustrative data from multiple time-synchronized device and body worn sensors are presented on a wheelchair user and a user of a “rollator” walking frame, moving along a walkway. Observation of the sensor data in both cases showed characteristic signatures corresponding to individual “pushes”. In parallel with this work, other project partners are exploring clinician and patient data requirements, as well we sensor set acceptability The initial results highlight the potential for the approach and demonstrate the need for further work to reduce and optimize the sensor set
- …