452 research outputs found

    Relationship Between LIBS Ablation and Pit Volume for Geologic Samples: Applications for the In Situ Absolute Geochronology

    Get PDF
    These first results demonstrate that LIBS spectra can be an interesting tool to estimate the ablated volume. When the ablated volume is bigger than 9.10(exp 6) cubic micrometers, this method has less than 10% of uncertainties. Far enough to be directly implemented in the KArLE experiment protocol. Nevertheless, depending on the samples and their mean grain size, the difficulty to have homogeneous spectra will increase with the ablated volume. Several K-Ar dating studies based on this approach will be implemented. After that, the results will be shown and discussed

    Matter-wave laser Interferometric Gravitation Antenna (MIGA): New perspectives for fundamental physics and geosciences

    Full text link
    The MIGA project aims at demonstrating precision measurements of gravity with cold atom sensors in a large scale instrument and at studying the associated applications in geosciences and fundamental physics. The first stage of the project (2013-2018) will consist in building a 300-meter long optical cavity to interrogate atom interferometers and will be based at the low noise underground laboratory LSBB in Rustrel, France. The second stage of the project (2018-2023) will be dedicated to science runs and data analyses in order to probe the spatio-temporal structure of the local gravity field of the LSBB region, a site of high hydrological interest. MIGA will also assess future potential applications of atom interferometry to gravitational wave detection in the frequency band 0.110\sim 0.1-10 Hz hardly covered by future long baseline optical interferometers. This paper presents the main objectives of the project, the status of the construction of the instrument and the motivation for the applications of MIGA in geosciences. Important results on new atom interferometry techniques developed at SYRTE in the context of MIGA and paving the way to precision gravity measurements are also reported.Comment: Proceedings of the 50th Rencontres de Moriond "100 years after GR", La Thuile (Italy), 21-28 March 2015 - 10 pages, 5 figures, 23 references version2: added references, corrected typo

    The Problem of Marginality in Model Reductions of Turbulence

    Full text link
    Reduced quasilinear (QL) and nonlinear (gradient-driven) models with scale separations, commonly used to interpret experiments and to forecast turbulent transport levels in magnetised plasmas are tested against nonlinear models without scale separations (flux-driven). Two distinct regimes of turbulence -- either far above threshold or near marginal stability -- are investigated with Boltzmann electrons. The success of reduced models especially hinges on the reproduction of nonlinear fluxes. Good agreement between models is found above threshold whilst reduced models would significantly underpredict fluxes near marginality, overlooking mesoscale flow organisation and turbulence self-advection. Constructive prescriptions whereby to improve reduced models is discussed

    Gas-liquid mass transfer : a comparison of down-and up-pumping axial flow impellers with radial impellers

    Get PDF
    The performance of a down- and up-pumping pitched blade turbine and A315 for gas-liquid dispersion and mass transfer was evaluated and then compared with that of Rushton and Scaba turbines in a small laboratory scale vessel. The results show that when the axial flow impellers are operated in the up-pumping mode, the overall performance is largely improved compared with the down-pumping configuration. Compared with the radial turbines, the up-pumping A315 has a high gas handling capacity, equivalent to the Scaba turbine and is economically much more efficient in terms of mass transfer than both turbines. On the other hand, the uppumping pitched blade turbine is not as well adapted to such applications. Finally, the axial flow impellers in the down-pumping mode have the lowest performance of all the impellers studied, although the A315 is preferred of the pitched blade turbine

    X-Ray Microanalysis of Calcium Containing Organelles in Resin Embedded Tissue

    Get PDF
    The localization of calcium in cell organelles at the electron microscope level is often achieved through cytochemical techniques, and verified by X-ray microanalysis. Various methods have been used to cytochemically detect calcium or calcium-binding sites : calcium loading, calcium substitution by strontium, barium, or even lead, and calcium precipitation by oxalate, phosphate, fluoride, or pyroantimonate. Their results may have heuristic value, particularly in preliminary studies of poorly known cell types. A complementary and more physiological approach is offered by quantitative measurement of the total calcium content of organelles after cryofixation. Resin embedding is less demanding than cryomicrotomy and gives better images : it can be used after cryosubstitution in the presence of oxalic acid. This technique was tested, and applied to several cell types

    The impacts of water vapour and co-pollutants on the performance of electrochemical gas sensors used for air quality monitoring

    Get PDF
    The analytical performance of low cost air pollution sensors under real-world conditions is a key factor that will influence their future uses and adoption. In this study five different electrochemical gas sensors (O3, SO2, CO, NO, NO2) are tested for their performance when challenged with cross interferences of water vapour and other gaseous co-pollutants. These experiments were conducted under both controlled laboratory conditions and during ambient air monitoring in urban background air at a site in York, UK. Signal outputs for O3, SO2 and CO showed a positive linear dependence on relative humidity (RH). The output for the NO sensor showed a negative correlation. The output for the NO2 sensor showed no trend with RH. Potential co-pollutants (O3, SO2, CO, NO2, NO and CO2) were introduced under controlled conditions using gas standards and delivered to each sensor in series along with variable RH. A matrix of cross-interference sensitivities were established which could be used to correct sensor signals. Interference-corrected sensor responses were compared against reference observations over an 18-day period. Once cross interferences had been removed the corrected 5 min averaging data for O3, CO, NO and NO2 sensors showed good agreement with the reference techniques with r2 values of 0.89, 0.76, 0.72, and 0.69, respectively. The SO2 sensor could not be evaluated in ambient air since ambient SO2 was below the sensor limit of detection

    The impacts of water vapour and co-pollutants on the performance of electrochemical gas sensors used for air quality monitoring

    Get PDF
    The analytical performance of low cost air pollution sensors under real-world conditions is a key factor that will influence their future uses and adoption. In this study five different electrochemical gas sensors (O3, SO2, CO, NO, NO2) are tested for their performance when challenged with cross interferences of water vapour and other gaseous co-pollutants. These experiments were conducted under both controlled laboratory conditions and during ambient air monitoring in urban background air at a site in York, UK. Signal outputs for O3, SO2 and CO showed a positive linear dependence on relative humidity (RH). The output for the NO sensor showed a negative correlation. The output for the NO2 sensor showed no trend with RH. Potential co-pollutants (O3, SO2, CO, NO2, NO and CO2) were introduced under controlled conditions using gas standards and delivered to each sensor in series along with variable RH. A matrix of cross-interference sensitivities were established which could be used to correct sensor signals. Interference-corrected sensor responses were compared against reference observations over an 18-day period. Once cross interferences had been removed the corrected 5 min averaging data for O3, CO, NO and NO2 sensors showed good agreement with the reference techniques with r2 values of 0.89, 0.76, 0.72, and 0.69, respectively. The SO2 sensor could not be evaluated in ambient air since ambient SO2 was below the sensor limit of detection

    Clinical outcomes and cost effectiveness of computerâ guided versus conventional implantâ retained hybrid prostheses: A longâ term retrospective analysis of treatment protocols

    Full text link
    BackgroundComputerâ guided systems were developed to facilitate implant placement at optimal positions in relation to the future prosthesis. However, the time, cost and, technique sensitivity involved with computerâ guided surgery impedes its routine practice. The aim of this study is to evaluate survival rates and complications associated with computerâ guided versus conventional implant placement in implantâ retained hybrid prostheses. Furthermore, longâ term economic efficiency of this approach was assessed.MethodsPatients were stratified according to implant placement protocol into a test group, using computerâ guided placement, and a control group, using traditional placement. Calibrated radiographs were used to measure bone loss around implants. Furthermore, the costs of the initial treatment and prosthetic complications, if any, were standardized and analyzed.ResultsFortyâ five patients (149 implants in the test group and 111 implants in the control group) with a minimum followâ up of 5 years, and a mean followâ up of 9.6 years, were included in the study. While no significant difference was found between both groups in terms of biologic and technical complications, lower incidence of implant loss was observed in the test group (P  0.05).ConclusionsComputerâ guided implant placement for an implantâ supported hybrid prosthesis is a valid, reliable alternative to the traditional approach for implant placement and immediate loading. Computerâ guided implant placement showed higher implant survival rates and comparable longâ term cost to nonâ guided implant placement.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/145504/1/jper10157.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/145504/2/jper10157_am.pd
    corecore