37 research outputs found

    Targeted tibio-peroneal re-entry during subintimal revascularization using the Outback® catheter

    Get PDF
    Background!#!Re-entry devices are used regularly in subintimal recanalization of chronic occlusions of the iliac and femoro-popliteal arteries and significantly contribute to the high success rate of these interventions. However, the use in tibio-peroneal arteries has only been described in few cases so far. The present work is a retrospective evaluation of the Outback® re-entry device for gaining targeted true lumen access at the level of the tibio-peroneal arteries.!##!Methods!#!From 9/2017 until 10/2020 the Outback® catheter was used in case of failed spontaneous re-entry at the level of the tibio-peroneal arteries in 14 patients either instead of the usual retrograde approach via a pedal/distal-crural access (n = 11) or in combination with it (n = 3). Baseline demographic and clinical data, morphologic characteristics of the occlusions, procedural succedss, as well as the Society of Vascular Surgery (SVS) runoff score before and after revascularization were documented.!##!Results!#!All patients (median age: 78 years; range: 66-93) suffered from peripheral artery occlusive disease Rutherford stage 4 to 6 with a median lesion length of 12 cm (range: 7-35). Technical and procedural success was achieved in all 14 patients. The mean re-entry accuracy was 0.25 cm (range: 0-0.8). The SVS runoff score improved from a median of 14.5 (interquartile range IQR: 10.8-16.4) to 7 (IQR: 6.3-7) (p < 0.01).!##!Conclusions!#!The use of the Outback® catheter for targeted tibio-peroneal re-entry is associated with a high technical and procedural success rate and should be considered in case of otherwise failed ante- and retrograde recanalization

    Evaluation of ECG-gated, high-pitch thoracoabdominal angiographies with dual-source photon-counting detector computed tomography

    Get PDF
    Purpose: The aim of this study was to evaluate the radiation dose, image quality, and the potential of virtual monoenergetic imaging (VMI) reconstructions of high-pitch computed tomography angiography (CTA) of the thoracoabdominal aorta on a dual-source photon-counting detector–CT (PCD-CT) in comparison with an energy-integrating detector–CT (EID-CT), with a special focus on low-contrast attenuation. Methods: Consecutive patients being referred for an electrocardiogram (ECG)-gated, high-pitch CTA of the thoracoabdominal aorta prior to transcatheter aortic valve replacement (TAVR), and examined on the PCD-CT, were included in this prospective single-center study. For comparison, a retrospective patient group with ECG-gated, high-pitch CTA examinations of the thoracoabdominal aorta on EID-CT with a comparable scan protocol was matched for gender, body mass index, height, and age. Virtual monoenergetic imaging reconstructions from 40 to 120 keV were performed. Enhancement and noise were measured in 7 vascular segments and the surrounding air as mean and standard deviation of CT values. The radiation dose was noted and signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated. Finally, a subgroup analysis was performed, comparing VMI reconstructions from 40 keV to 70 keV in patients with at least a 50% decrease in contrast attenuation between the ascending aorta and femoral arteries. Results: Fifty patients (mean age 77.0±14.5 years; 31 women) were included. The radiation dose was significantly lower on the PCD-CT (4.2±1.4 vs. 7.2±2.2 mGy; p<0.001). With increasing keV, vascular noise, SNR, and CNR decreased. Intravascular attenuation was significantly higher on VMI at levels from 40 to 65, compared with levels of 120 keV (p<0.01 and p<0.005, respectively). On the PCD-CT, SNR was significantly higher in keV levels 40 and 70 (all p<0.001), and CNR was higher at keV levels 40 and 45 (each p<0.001), compared with scans on the EID-CT. At VMI ≤60 keV, image noise was also significantly higher than that in the control group. The subgroup analysis showed a drastically improved diagnostic performance of the low-keV images in patients with low-contrast attenuation. Conclusion: The ECG-gated CTA of the thoracoabdominal aorta in high-pitch mode on PCD-CT have significantly lower radiation dose and higher objective image quality than EID-CT. In addition, low-keV VMI can salvage suboptimal contrast studies, further reducing radiation dose by eliminating the need for repeat scans. Clinical Impact ECG-gated CT-angiographies of the thoracoabdominal aorta can be acquired with a lower radtiation dose and a better image quality by using a dual-source photon-countinge detector CT. Furthermore, the inherent spectral data offers the possiblity to improve undiagnostic images and thus saves the patient from further radiation and contrast application

    Sexuality and Body Image After Uterine Artery Embolization and Hysterectomy in the Treatment of Uterine Fibroids: A Randomized Comparison

    Get PDF
    In this paper the effect of uterine artery embolization (UAE) on sexual functioning and body image is investigated in a randomized comparison to hysterectomy for symptomatic uterine fibroids. The EMbolization versus hysterectoMY (EMMY) trial is a randomized controlled study, conducted at 28 Dutch hospitals. Patients were allocated hysterectomy (n = 89) or UAE (n = 88). Two validated questionnaires (the Sexual Activity Questionnaire [SAQ] and the Body Image Scale [BIS]) were completed by all patients at baseline, 6 weeks, and 6, 12, 18, and 24 months after treatment. Repeated measurements on SAQ scores revealed no differences between the groups. There was a trend toward improved sexual function in both groups at 2 years, although this failed to reach statistical significance except for the dimensions discomfort and habit in the UAE arm. Overall quality of sexual life deteriorated in a minority of cases at all time points, with no significant differences between the groups (at 24 months: UAE, 29.3%, versus hysterectomy, 23.5%; p = 0.32). At 24 months the BIS score had improved in both groups compared to baseline, but the change was only significant in the UAE group (p = 0.009). In conclusion, at 24 months no differences in sexuality and body image were observed between the UAE and the hysterectomy group. On average, both after UAE and hysterectomy sexual functioning and body image scores improved, but significantly so only after UAE

    The role of selenium, vitamin C, and zinc in benign thyroid diseases and of selenium in malignant thyroid diseases: Low selenium levels are found in subacute and silent thyroiditis and in papillary and follicular carcinoma

    Get PDF

    Isolierte Iliakalarterienaneurysmen: klinischer Hintergrund und interventionelle Versorgungsstrategien

    No full text

    Isolierte Iliakalarterienaneurysmen

    Full text link
    corecore