680 research outputs found

    Patient-specific image-based computer simulation for theprediction of valve morphology and calcium displacement after TAVI with the Medtronic CoreValve and the Edwards SAPIEN valve

    Get PDF
    AIMS: Our aim was to validate patient-specific software integrating baseline anatomy and biomechanical properties of both the aortic root and valve for the prediction of valve morphology and aortic leaflet calcium displacement after TAVI. METHODS AND RESULTS: Finite element computer modelling was performed in 39 patients treated with a Medtronic CoreValve System (MCS; n=33) or an Edwards SAPIEN XT (ESV; n=6). Quantitative axial frame morphology at inflow (MCS, ESV) and nadir, coaptation and commissures (MCS) was compared between multislice computed tomography (MSCT) post TAVI and a computer model as well as displacement of the aortic leaflet calcifications, quantified by the distance between the coronary ostium and the closest calcium nodule. Bland-Altman analysis revealed a strong correlation between the observed (MSCT) and predicted frame dimensions, although small differences were detected for, e.g., Dmin at the inflow (mean±SD MSCT vs. MODEL: 21.6±2.4 mm vs. 22.0±2.4 mm; difference±SD: -0.4±1.3 mm, p<0.05) and Dmax (25.6±2.7 mm vs. 26.2±2.7 mm; difference±SD: -0.6±1.0 mm, p<0.01). The observed and predicted calcium displacements were highly correlated for the left and right coronary ostia (R2=0.67 and R2=0.71, respectively p<0.001). CONCLUSIONS: Dedicated software allows accurate prediction of frame morphology and calcium displacement after valve implantation, which may help to improve outcome

    Observability of dynamical networks from graphic and symbolic approaches

    Full text link
    A dynamical network, a graph whose nodes are dynamical systems, is usually characterized by a large dimensional space which is not always accesible due to the impossibility of measuring all the variables spanning the state space. Therefore, it is of the utmost importance to determine a reduced set of variables providing all the required information for non-ambiguously distinguish its different states. Inherited from control theory, one possible approach is based on the use of the observability matrix defined as the Jacobian matrix of the change of coordinates between the original state space and the space reconstructed from the measured variables. The observability of a given system can be accurately assessed by symbolically computing the complexity of the determinant of the observability matrix and quantified by symbolic observability coefficients. In this work, we extend the symbolic observability, previously developed for dynamical systems, to networks made of coupled dd-dimensional node dynamics (d>1d>1). From the observability of the node dynamics, the coupling function between the nodes, and the adjacency matrix, it is indeed possible to construct the observability of a large network with an arbitrary topology.Comment: 12 pages, 4 figures made from 12 eps file

    Integrating cross-frequency and within band functional networks in resting-state MEG: A multi-layer network approach

    Get PDF
    Neuronal oscillations exist across a broad frequency spectrum, and are thought to provide a mechanism of interaction between spatially separated brain regions. Since ongoing mental activity necessitates the simultaneous formation of multiple networks, it seems likely that the brain employs interactions within multiple frequency bands, as well as cross-frequency coupling, to support such networks. Here, we propose a multi-layer network framework that elucidates this pan-spectral picture of network interactions. Our network consists of multiple layers (frequency-band specific networks) that influence each other via inter-layer (cross-frequency) coupling. Applying this model to MEG resting-state data and using envelope correlations as connectivity metric, we demonstrate strong dependency between within layer structure and inter-layer coupling, indicating that networks obtained in different frequency bands do not act as independent entities. More specifically, our results suggest that frequency band specific networks are characterised by a common structure seen across all layers, superimposed by layer specific connectivity, and inter-layer coupling is most strongly associated with this common mode. Finally, using a biophysical model, we demonstrate that there are two regimes of multi-layer network behaviour; one in which different layers are independent and a second in which they operate highly dependent. Results suggest that the healthy human brain operates at the transition point between these regimes, allowing for integration and segregation between layers. Overall, our observations show that a complete picture of global brain network connectivity requires integration of connectivity patterns across the full frequency spectrum

    Cardiac Catheterizations in Patients With Prior Coronary Bypass Surgery:Impact of Access Strategy on Short-Term Safety and Long-Term Efficacy Outcomes

    Get PDF
    Little data are available on access strategy outcomes for cardiac catheterizations in patients with prior coronary artery bypass graft surgery (CABG). We investigated the effect of transradial access (TRA) and transfemoral access (TFA) on short-term major vascular complications (MVC) and long-term major adverse cardiovascular events (MACE). In this single-center, retrospective cohort study, 1084 patients met our inclusion criteria (TRA = 469; TFA = 615). The cumulative incidence for the primary safety endpoint MVC at 30 days (a composite of major bleeding, retroperitoneal hematoma, dissection, pseudoaneurysm, and arteriovenous fistula) was lower with TRA (0.7% vs 3.0%, P &lt;.01) and this difference remained significant after propensity score adjustment (odds ratio: 0.24; 95% CI, 0.07-0.83; P =.024). The cumulative incidence for the primary efficacy endpoint MACE at 36 months (a composite of all-cause mortality, myocardial infarction, stroke, and urgent target vessel revascularization) was 28.6% with TRA and 27.6% with TFA, respectively. Kaplan-Meier curves showed no difference for the primary efficacy endpoint (P =.65). Contrast use (mL) was significantly lower with TRA (130 [100-180] vs 150 [100-213], P &lt;.01). In conclusion, in patients with prior CABG, TRA was associated with significantly fewer short-term MVC and contrast use, but not with a difference in long-term MACE, compared with TFA.</p

    Determinants of image quality of rotational angiography for on-line assessment of frame geometry after transcatheter aortic valve implantation

    Get PDF
    To study the determinants of image quality of rotational angiography using dedicated research prototype software for motion compensation without rapid ventricular pacing after the implantation of four commercially available catheter-based valves. Prospective observational study including 179 consecutive patients who underwent transcatheter aortic valve implantation (TAVI) with either the Medtronic CoreValve (MCS), Edward-SAPIEN Valve (ESV), Boston Sadra Lotus (BSL) or Saint-Jude Portico Valve (SJP) in whom rotational angiography (R-angio) with motion compensation 3D image reconstruction was performed. Image quality was evaluated from grade 1 (excellent image quality) to grade 5 (strongly degraded). Distinction was made between good (grades 1, 2) and poor image quality (grades 3–5). Clinical (gender, body mass index, Agatston score, heart rate and rhythm, artifacts), procedural (valve type) and technical variables (isocentricity) were related with the image quality assessment. Image quality was good in 128 (72 %) and poor in 51 (28 %) patients. By univariable analysis only valve type (BSL) and the presence of an artefact negatively affected image quality. By multivariate analysis (in which BMI was forced into the model) BSL valve (Odds 3.5, 95 % CI [1.3–9.6], p = 0.02), presence of an artifact (Odds 2.5, 95 % CI [1.2–5.4], p = 0.02) and BMI (Odds 1.1, 95 % CI [1.0–1.2], p = 0.04) were independent predictors of poor image quality. Rotational angiography with motion compensation 3D image reconstruction using a dedicated research prototype software offers good image quality for the evaluation of frame geometry after TAVI in the majority of patients. Valve type, presence of artifacts and higher BMI negatively affect image quality

    The role of epidemic spreading in seizure dynamics and epilepsy surgery

    Get PDF
    AbstractEpilepsy surgery is the treatment of choice for drug-resistant epilepsy patients, but only leads to seizure freedom for roughly two in three patients. To address this problem, we designed a patient-specific epilepsy surgery model combining large-scale magnetoencephalography (MEG) brain networks with an epidemic spreading model. This simple model was enough to reproduce the stereo-tactical electroencephalography (SEEG) seizure propagation patterns of all patients (N = 15), when considering the resection areas (RA) as the epidemic seed. Moreover, the goodness of fit of the model predicted surgical outcome. Once adapted for each patient, the model can generate alternative hypothesis of the seizure onset zone and test different resection strategies in silico. Overall, our findings indicate that spreading models based on patient-specific MEG connectivity can be used to predict surgical outcomes, with better fit results and greater reduction on seizure propagation linked to higher likelihood of seizure freedom after surgery. Finally, we introduced a population model that can be individualized by considering only the patient-specific MEG network, and showed that it not only conserves but improves the group classification. Thus, it may pave the way to generalize this framework to patients without SEEG recordings, reduce the risk of overfitting and improve the stability of the analyses

    OCT assessment of the long-term vascular healing response 5 years after everolimus-eluting bioresorbable vascular scaffold

    Get PDF
    AbstractBackgroundAlthough recent observations suggest a favorable initial healing process of the everolimus-eluting bioresorbable vascular scaffold (BVS), little is known regarding long-term healing response.ObjectivesThis study assessed the in vivo vascular healing response using optical coherence tomography (OCT) 5 years after elective first-in-man BVS implantation.MethodsOf the 14 living patients enrolled in the Thoraxcenter Rotterdam cohort of the ABSORB A study, 8 patients underwent invasive follow-up, including OCT, 5 years after implantation. Advanced OCT image analysis included luminal morphometry, assessment of the adluminal signal-rich layer separating the lumen from other plaque components, visual and quantitative tissue characterization, and assessment of side-branch ostia “jailed” at baseline.ResultsIn all patients, BVS struts were integrated in the vessel and were not discernible. Both minimum and mean luminal area increased from 2 to 5 years, whereas lumen eccentricity decreased over time. In most patients, plaques were covered by a signal-rich, low-attenuating layer. Minimum cap thickness over necrotic core was 155 ± 90 μm. One patient showed plaque progression and discontinuity of this layer. Side-branch ostia were preserved with tissue bridge thinning that had developed in the place of side-branch struts, creating a neo-carina.ConclusionsAt long-term BVS follow-up, we observed a favorable tissue response, with late luminal enlargement, side-branch patency, and development of a signal-rich, low-attenuating tissue layer that covered thrombogenic plaque components. The small size of the study and the observation of a different tissue response in 1 patient warrant judicious interpretation of our results and confirmation in larger studies

    Patients with aortic stenosis referred for TAVI: treatment decision, in-hospital outcome and determinants of survival

    Get PDF
    Aims To assess treatment decision and outcome in patients referred for transcatheter aortic valve implantation (TAVI) in addition to predictive factors of mortality after TAVI. Methods Three-centre prospective observational study including 358 patients. Endpoints were defined according to the Valve Academic Research Consortium. Results Of the 358 patients referred for TAVI, TAVI was performed in 235 patients (65%), surgical aortic valve replacement (AVR) in 24 (7%) and medical therapy (MT) in 99 (28%). Reasons to decline TAVI in favour of AVR/MT were patient preference (29%), peripheral vascular disease (15%) and non-severe aortic stenosis (11%). The logistic EuroSCORE was significantly higher in patients who underwent TAVI and MT in comparison with those undergoing AVR (19 vs. 10%, p=0.007). At 30 days, all-cause mortality and the combined safety endpoint were 9 and 24% after TAVI and 8 and 25% after AVR, respectively. All-cause mortality was significantly lower in the TAVI group compared with the MT group at 6 months, 1 year and 2 years (12% vs. 22%, 21% vs. 33% and 31% vs. 55%, respectively, p<0.001). Multivariable analysis revealed that blood transfusion (HR: 1.19; 95% CI: 1.05-1.33), pre-existing renal failure (HR: 1.18; 95% CI: 1.06-1.33) and STS score (HR: 1.06; 95% CI: 1.02-1.10) were independent predictors of mortality at a median of 10 (IQR: 3-23) months after TAVI. Conclusions Approximately two-thirds of the patients referred for TAVI receive this treatment with gratifying short- and long-term survival. Another 7% underwent AVR. Prognosis is poor in patients who do not receive valve replacement therapy
    • …
    corecore