    Temporary device malfunction of an MR conditional cardiac resynchronization defibrillator when undergoing MRI without appropriate re-programming: a case report

    Get PDF
    Background Magnetic resonance (MR) imaging (MRI) for patients with implantable cardiac devices is becoming more routine, with the development of MR conditional devices allowing more patients access to the imaging they need. However, for this to be performed safely, strict protocols must be followed necessitating close collaboration between cardiology and radiology departments. We present a case where mandatory device re-programming of a cardiac resynchronization therapy defibrillator device into MRI mode was not performed pre-scan leading to temporary device dysfunction with no clinical consequences. Case summary A 72-year-old man presented to a device clinic for a routine device interrogation. An atrial tachycardia response episode was recorded at the same time as the patient reported having undergone an MRI scan at a local centre. The electrogram demonstrated temporary right ventricular loss of capture with standard output programming, and a short episode of oversensing on the atrial and ventricular channel which was not sustained for long enough to meet tachycardia detection. Discussion We demonstrate two potential electrophysiological effects of MRI on pacemakers, where the device had not been appropriately re-programmed pre-procedure. This illustrates that whilst MRI in patients with implantable cardiac devices is safe, strict protocols must be followed requiring robust multidisciplinary communication

    Graft-versus-host disease: a case report of a rare but reversible cause of constrictive pericarditis

    Get PDF
    BACKGROUND: Constrictive pericarditis (CP), although an uncommon cause of heart failure, requires specialist multidisciplinary input and multi-modality imaging to identify the underlying aetiology and treat potentially reversible causes. CASE SUMMARY: We report the case of a 74-year-old gentleman referred for assessment of progressive exertional dyspnoea and peripheral oedema, 30 months following treatment of acute myeloid leukaemia with high-dose chemotherapy and allogeneic stem cell transplantation. Clinical examination and cardiac imaging revealed a small pericardial effusion and pericardial thickening with constrictive physiology; however, no aetiology was identified despite diagnostic pericardiocentesis. The patient required recurrent hospital admissions for intravenous diuresis, therefore, following multidisciplinary discussions, surgical partial pericardectomy was performed. Histology suggested graft-vs.-host disease (GvHD) and post-operatively, the patient improved clinically. Following immunomodulatory therapy with ruxolitinib for both pericardial and pulmonary GvHD, his functional status improved further with no subsequent hospital admissions. DISCUSSION: Although pericardial disease in cancer patients is common, CP is unusual. Determining the underlying aetiology is important for subsequent management, and here, we describe the use of multi-modality imaging to diagnose a rare cause, GvHD, which responded to surgical treatment and immunomodulatory therapy

    Provision of magnetic resonance imaging for patients with 'MR-conditional' cardiac implantable electronic devices: an unmet clinical need

    Get PDF
    Aims Increasing need for magnetic resonance imaging (MRI) has driven the development of MR-conditional cardiac implantable electronic devices (CIEDs; pacemakers and defibrillators); however, patients still report difficulties obtaining scans. We sought to establish current provision for MRI scanning of patients with CIEDs in England. Methods and results A survey was distributed to all hospitals in England with MRI, to assess current practice. Information requested included whether hospitals currently offer MRI to this patient group, the number and type of scans acquired, local safety considerations, complications experienced and perceived obstacles to service provision in those departments not currently offering it. Responses were received from 195 of 227 (86%) of hospitals surveyed. Although 98% of departments were aware of MR-conditional devices, only 46% (n = 89) currently offer MRI scans to patients with CIED's; of these, 85% of departments perform ≤10 scans per year. No major complications were reported from MRI scanning in patients with MR-conditional devices. Current barriers to service expansion include perceived concerns regarding potential risk, lack of training, logistical difficulties, and lack of cardiology support. Conclusion Provision of MRI for patients with CIEDs is currently poor, despite increasing numbers of patients with MR-conditional devices and extremely low reported complication rates

    Limited value of pulse wave analysis in assessing arterial wave reflection and stiffness in the pulmonary artery

    Get PDF
    We explored the use of the augmentation index (AI) based on pulse wave analysis (PWA) in the pulmonary circulation as a measure of wave reflection and arterial stiffness in individuals with and without pulmonary arterial hypertension (PAH) and chronic thromboembolic pulmonary hypertension (CTEPH). Right heart catheterization was performed using a pressure and Doppler flow sensor–tipped catheter to obtain simultaneous pressure and flow velocity measurements in the pulmonary artery in 10 controls, 11 PAH patients, and 11 CTEPH patients. PWA was applied to the measured pressure, while wave intensity analysis (WIA) and wave separation analysis (WSA) were performed using both the pressure and velocity to determine the magnitudes and timings of reflected waves. Type C (AI 12%) waveform dominated in PAH patients, while there was a mixture of types A, B, and C among CTEPH patients. AI was greater and the inflection time shorter in CTEPH compared to PAH patients. There was a poor correlation between AI and arterial wave speed as well as measures of wave reflection derived from WIA and WSA. The infection point did not match the timing of the backward compression wave in ~50% of the cases. In patients with type C waveforms, the inflection time correlated well to the timing of the late systolic forward decompression wave caused by ventricular relaxation. In conclusion quantifying pulmonary arterial wave reflection and stiffness using AI based on PWA may be inaccurate and should therefore be discouraged

    Optimising cardiovascular care of patients with multiple myeloma

    Get PDF
    Multiple myeloma (MM) is the third most common haematological malignancy, with increasing prevalence over recent years. Advances in therapy have improved survival, changing the clinical course of MM into a chronic condition and meaning that management of comorbidities is fundamental to improve clinical outcomes. Cardiovascular (CV) events affect up to 7.5% of individuals with MM, due to a combination of patient, disease and treatment-related factors and adversely impact survival. MM typically affects older people, many with pre-existing CV risk factors or established CV disease, and the disease itself can cause renal impairment, anaemia and hyperviscosity, which exacerabate these further. Up to 15% of patients with MM develop systemic amyloidosis, with prognosis determined by the extent of cardiac involvement. Management of MM generally involves administration of multiple treatment lines over several years as disease progresses, with many drug classes associated with adverse CV effects including high rates of venous and arterial thrombosis alongside heart failure. Recommendations for holistic management of patients with MM now include routine baseline risk stratification including ECG and echocardiography and administration of thromboprophylaxis drugs for patients treated with immunomodulatory drugs. Close surveillance of high-risk patients with collaboration between haematology and cardiology is required, with prompt investigation in the event of CV symptoms, in order to identify and treat complications early. Decisions regarding discontinuation of cardiotoxic therapies should be made in a multidisciplinary setting, taking into account the severity of the complication, prognosis, expected benefits and the availability of effective alternatives
    • …